References
- A
neja S., Taylor J.S., Soldes O., Dermatitis in patients undergoing the Nuss procedurefor correction of pectus excavatum, Contact Dermatitis, 2011, 65, DOI: 10.1111/j.1600-0536.2011.01966.x. - B
aranowska J., Arnold B., Corrosion resistance of nitrided layers on austenitic steel, Surf. Coat. Technol., 2006, 22–23 (200), DOI: 10.1016/j.surfcoat.2005.11.099. - B
asiaga M., Jendruś R., Walke W., Paszenda Z., Kaczmarek M., Popczyk M., Influence of surface modification on properties of stainless steel used for implants, Arch. Metall. Mater., 2015, 60, DOI: 10.1515/AMM-2015-0473. - B
asiaga M., Walke W., Staszuk M., Kajzer W., Kajzer A., Nowińska K., Influence of ALD process parameters on the physical and chemical properties of the surface of vascular stents, Arch. Civ. Mech. Eng., 2017, 17, https://doi.org/10.1016/j.acme.2016.08.001 - B
orowski T., Adamczyk-cieślak B., Brojanowska A., Kulikowski K., Wierzchoń T., Surface modification of austenitic steel by various glow-discharge nitriding methods, Mater. Sci., 2015, 21 (3), DOI: 10.5755/J01.MS.21.3.7404. - B
yrski A., Kopernik M., Major Ł., Kasperkiewicz K., Dyner M., Lackner J.M., Lumenta D., Major R., Characterization of biomaterials with reference to biocompatibility dedicated for patient-specific finger implants, Acta Bioeng. Biomech., 2023, 25 (1), DOI: 10.37190/ABB-02156-2022-02. - C
asamassima M.G.S., Goldstein S.D., Salazar J.H., Mciltrot K.H., Abdullah F., Colombani P.M., Peri-operative strategies and technical modifications to the Nuss repair for pectus excavatum in pediatric patients: A large volume, single institution experience, J. Pediatr. Surg., 2014, 49 (4), DOI: 10.1016/j.jpedsurg.2013.11.058. - C
heng Z., Li C.X., Dong H., Bell T., Low temperature plasma nitrocarburising of AISI 316 austenitic stainless steel, Surf. Coat. Technol., 2005, 2–3 (191), DOI: 10.1016/j.surfcoat.2004.03.004. - D
e sousa R.R.M., De araújo F.O., Gontijo L.C., Da Costa J.A.P., Alves C.Jr., Cathodic cage plasma nitriding (CCPN) of austenitic stainless steel (AISI 316): Influence of the different ratios of the (N2/H2) on the nitrided layers properties, Vacuum, 2012, (17) 2, DOI: 10.1590/S1516-14392013005000197. - G
oldsztajn K., Godzierz M., Hercog A., Władowski M., Jaworska J., Jelonek K., Woźniak W., Kajzer A., Orłowska A., Szewczenko J., Properties of biodegradable polymer coatings with hydroxyapatite on a titanium alloy substrate, Acta Bioeng. Biomech., 2024, 26 (1), DOI: 10.37190/ABB-02351-2023-03. - G
órecki A., Babiak I., Leczenie zakażeń w obrębie narządu ruchu. Antybiotyki w profilaktyce i leczeniu zakażeń, Wydawnictwo Lekarskie PZWL, 2001. - G
regory D., Michael J., Goretsky T., Maripaz M., Kelly R.E. Jr., Nuss D., When it is not an infection: metal allergy after the Nuss procedure for repair of pectus excavatum, J. Pediatr. Surg., 2007, 42 (1), DOI: 10.1016/j.jpedsurg. 2006.09.056. - H
aïdopoulos M., Turgeon S., Sarra-bournet C., Laroche G., Mantovani D., Development of an optimized electrochemical process for subsequent coating of 316 stainless steel for stent applications, J. Mater. Sci. Mater. Med., 2006, 17, DOI: 10.1007/s10856-006-9228-4. - H
ryniewicz T., Rokicki R., Rokosz K., Surface characterization of AISI 316L biomaterials obtained by electropolishing in a magnetic field, Surf. Coat. Technol., 2008, (202) 9, DOI: 10.1016/j.surfcoat.2007.07.067. - ISO 10993-5 – Biological evaluation of medical devices. Part 5: Tests for in vitro cytotoxicity.
- ISO 5832-1: Implants for surgery – Metallic materials. Part 1: Wrought stainless steel.
- A
fifah J.Z., Azmi F., Basak A., Ghani J., Kasim M.S., Alias R., Tribological and corrosion behaviour of medical grade 316LVM steel by low temperature hybrid gaseous nitriding and carburizing, Tribol. Int., 2023, 190, DOI: 10.1016/j.triboint.2023.109026. - K
ajzer A., Kajzer W., Dzielicki J., Matejczyk D., The study of physicochemical properties of stabilizing plates removed from the body after treatment of pectus excavatum, Acta Bioeng. Biomech., 2015, 2, DOI: 10.5277/ABB-00140-2014-02. - K
ajzer A., Rabij K., Basiaga M., Nowińska K., Kaczmarek M., Borowski T., Wierzchoń T., Influence of sterilization and exposure to the Ringer’s solution on mechanical and physicochemical properties of nitrocarburized 316 LVM steel, Arch. Metall. Mater., 2018, (63) 3, DOI: 10.24425/123799. - K
ajzer W., Kajzer A., Grygiel-pradelok M., Ziębowicz A., Ziębowicz B., Evaluation of physicochemical properties of TiO2 layer on AISI 316 LVM stainless steel intented for urology, Springer International Publishing, 2016, DOI: 10.1007/978-3-319-39904-1_34. - K
elly R.E., Goretsky M.J., Obermeyer R., Kuhn M.A., Redlinger R., Haney T.S., Moskowitz A., Nuss D., Twenty-one years of experience with minimally invasive repair of pectus excavatum by the Nuss procedure in 1215 patients, Ann. Surg., 2010, 163 (3), DOI: 10.1016/j.jtcvs.2020.11.154. - L
i X.Y., Thaiwatthana S., Dong H., Bell T., Thermal stability of carbon S phase in 316 stainless steel, Surf. Eng., 2002, 18, DOI: 10.1179/0267084022250062. - L
iu Y., Zhu D., Jeremy D.P., Gilbert L., Fretting Initiated Crevice Corrosion of 316LVM Stainless Steel in Physiological Phosphate Buffered Saline, Acta Biomater., 2019, (97) 1, DOI: 10.1016/j.actbio.2019.07.051. - M
artínez O.L., Pérez F.J., Gómez C., The effect of nitrogen ion implantation on the corrosion behaviour of stainless steels in chloride media, Surf. Coat. Technol., 2005, (200) 5–6, DOI: 10.1016/j.surfcoat.2005.08.034. - N
iua W., Lillarda R.S., Lib Z., Ernst F., Properties of the Passive Film Formed on Interstitially Hardened AISI 316L Stainless Steel, Electrochim. Acta., 2015, 176 (4), 410–419. - O
rłowska A., Szewczenko J., Kajzer W., Goldsztajn K., Basiaga M., Study of the effect of anodic oxidation on the corrosion properties of the Ti6Al4V implant produced from SLM, J. Funct. Biomater., 2023, 14 (4), DOI: 10.3390/jfb14040191. - P
ark H.J., Lee S.Y., Lee C.S., Complications associated with the Nuss procedure: analysis of risk factors and suggested measures for prevention of complications, J. Pediatr. Surg., 2004, 39 (3), DOI: 10.1016/j.jpedsurg.2003.11.012. - PN-EN ISO 10993-15. Biological evaluation of medical devices. Part 15: Identification and quantification of degradation products from metals and alloys.
- P
okrowiecki R., Tyski S., Zaleska M., Problematyka zakażeń okołowszczepowych, Post. Mikrobiol., 2014, 53 (2), 123–134. - R
osato E., Giovannetti A., Rossi C., Menghi G., Pisarri S., Salsano F., Recurrentinfections in patients with nickel allergic hypersensitivity, J. Biol. Regul. Homeost Agents, 2009, 23 (3), 173–180. - S
chalock P.C., Menné T., Johansen J.D., Hypersensitivity reactions to metallic implants − diagnostic algorithm and suggested patch test series for clinical use, Contact Dermatitis, 2011, 66, DOI: 10.1111/j.1600-0536.2011.01971.x. - S
hah B., Cohee A., Deyerle A., Kelly C.S., Frantz F., Kelly R.E., Kuhn M.A., Lombardo M., Obermeyer R., Goretsky M.J., High rates of metal allergy amongst Nuss procedure patients dictate broader pre-operative testing, J. Pediatr. Surg., 2014, (49) 3, DOI: 10.1016/j.jpedsurg.2013.07.014. - S
hen L., Wang L., Xu J.J., Plasma nitriding of AISI 304 austenitic stainless steel assisted with hollow cathode effect, Surf. Coat. Technol., 2013, (204) 20, DOI: 10.1016/j.surfcoat. 2010.03.018. - S
hin S., Goretsky M.J., Kelly R.E. JR, Gustin T., Nuss D., Infectious complications after the Nuss repair in a series of 863 patients, Pediatr. Surg., 2007, 42 (1), DOI: 10.1016/j.jpedsurg.2006.09.057. - W
anga X., Zhaoa L., Dinga M.H, Zhenga H., Zhanga H.S., Zhanga B., Lia X.Q., Wua G.Y., Surface modification of biomedical AISI 316L stainless steel withzirconium carbonitride coatings, Appl. Surf. Sci., 2015, 340, http://dx.doi.org/10.1016/j.apsusc.2015.02.191 - W
elch K.J., Satisfactory surgical correction of pectus excavatum deformity in childhood, J. Thorac. Surg., 1958, 36, 697–713. - W
ielowiejska G.A., Wiśniewski T., Rubach R., Fretting corrosion studies of materials used for elements of hip joint endoprostheses, Tribologia, 2018, 5, 143–151. - W
u P.C., Knauer E.M., Mcgowan G.E., Hight D.W., Repair of pectus excavatum deformities in children: a new perspective of treatment using minimal access surgical technique, Arch. Surg., 2016, 136 (4), 419–424. - Z
iębowicz A., Sambok-kiełbowicz A., Walke W., Mzyk A., Kosiel K., Kubacki J., Bączkowski B., Pawlyta M., Ziębowicz B., Evaluation of Bacterial Adhesion to the ZrO2 Atomic Layer Deposited on the Surface of Cobalt-Chromium Dental Alloy Produced by DMLS Method, Materials, 2021, 14 (5), DOI: 10.3390/ma14051079.