Skip to main content
Have a personal or library account? Click to login
Thoron (Rn-2 20) measurements in the atmosphere and their application in meteorology Cover

Thoron (Rn-2 20) measurements in the atmosphere and their application in meteorology

Open Access
|Jan 1965

Abstract

With new equipment which allows the continuous recording of the atmospheric thoron content down to 0.5·10−14 C/l, the thoron content of the atmosphere, at different levels was measured at the Meteorologisches Observatorium des Deutschen Wetterdienstes in Aachen. The measurements were carried out from June until September 1964.

The results show a close relation between the thoron content and the meteorological variables. The thoron concentration and its decrease with height shows a remarkable diurnal variation with a maximum at noon and a minimum during the night. The thoron at this station is influenced by wind direction. Rain diminished the thoron content by 50%; the recovery time to reach the initial concentration is about 10 hours.

It could be shown that the turbulent diffusion coefficient K increases linearly between 1 m and 4 m. A mean value of K = 330 ± 30 cm2/s at 1 m level was found.

Language: English
Page range: 383 - 388
Published on: Jan 1, 1965
Published by: Stockholm University Press
In partnership with: Paradigm Publishing Services

© 1965 Gerhard W. Israȅl, published by Stockholm University Press