Figures & Tables

Characteristics and performance of different methods for the identification of S_ aureus in the blood or blood cultures_

AssaysResistance markersSensitivityTurnaround time (h)SpecificityReferences
HybrisepnoneNANA8Shimada et al. 1999
T2Dxnone100%100%3–5De Angelis et al. 2018
BinaX Now S.aureusnone97.6%100%0.5Qian et al. 2014
BinaX Now PBP2ayes100%100%0.5Heraud et al. 2015
Gram stainingnone78.7%95%0.5Hadano et al. 2018
PNA FISHnone100%99.4%1.5–3González et al. 2004
QuickFISHnone99.5%89.5%0.5Deck et al. 2012
Accelerate PhenoTM systemsusceptibility94.7%99%ID1/AST 7Charnot-Katsikas et al. 2017
MALDI-TOF MSin development85.7–100%NA0.5–1 (pellet)/3–5 (short incubation)Foster 2013; Curtoni et al. 2017
FilmArray BCID2yes100%100%1Holma et al. 2022
Xpert MRSA/SA BCyes100%100%1McHugh et al. 2020

Comments on rapid and simple methods for the identification of S_ aureus from the blood or blood cultures_

AssaysAutomatedPersonnel experienceEquipment requirementThroughputCostComments
Hybrisepyesyesproprietary equipmentlowmoderate+: rapid, sensitive and specific–: limited number of publications
T2Dxyesnoproprietary equipmentlowhigh+: rapid, sensitive, and specific–: no resistance markers
BinaX Now S. aureusnononolowlow+: rapid, sensitive and specific–: cross-reaction with S. lugdunensis
BinaX Now PBP2anononolowlow+: rapid, sensitive, and specific–: no identification
Gram stainingyesyesgeneric equipmentlowlow+: rapid, simple–: variable sensitivity and specificity
PNA FISHnoyesgeneric equipmentlowhigh+: rapid, sensitive, and specific–: no resistance markers
QuickFISHnoyesgeneric equipmentlowhigh+: rapid, sensitive, and specific–: no resistance markers
Accelerate PhenoTM systemyesnoproprietary equipmentlowhigh+: rapid, sensitive, and specific, with AST results–: low throughout
MALDI-TOF MSnoyesproprietary equipmenthighlow+: rapid, sensitive, and specific, cost-effective–: enrichment, not standardization
FilmArray BCID2yesnoproprietary equipmentlowhigh+: rapid, sensitive, and specific, with resistance results–: low throughout
Xpert MRSA/SA BCyesnoproprietary equipmentlowhigh+: rapid, sensitive, and specific, with resistance results–: expensive
DOI: https://doi.org/10.33073/pjm-2022-050 | Journal eISSN: 2544-4646 | Journal ISSN: 1733-1331
Language: English
Page range: 481 - 489
Submitted on: Aug 29, 2022
Accepted on: Nov 1, 2022
Published on: Dec 9, 2022
Published by: Polish Society of Microbiologists
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2022 Rui Duan, Pei Wang, published by Polish Society of Microbiologists
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.