Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Physico-chemical parameters measured in the Kisielina and Szum rivers and in the cooling-water discharge channel of the Stalowa Wola Combined Heat and Power Plant (southern Poland)
| Parameter | Kisielina | Szum | Cooling-water channel |
|---|---|---|---|
| T[°C] | 2.6–16.0 | 6.7–16.3 | 19.7–21.2 |
| PH | 6.2–7.2 | 6.6–8.0 | 8.3–8.6 |
| EC [μS · cm−1] | 115–320 | 133.5–331 | 503–511 |
| Cl– [mg · L−1] | 10.55–28.94 | 0.07–9.17 | 10.67–13.58 |
| SO42- [mg · L−1] | 20.33–45.63 | 10.72–20.54 | 22.03–31.27 |
| PO43- [mg · L−1] | <0.001 | <0.001–0.15 | <0.001 |
| NO2– [mg · L−1] | <0.001 | <0.001–0.02 | <0.001 |
| NO3– [mg · L−1] | 2.31–8.09 | 0.13–6.60 | 2.55–2.79 |
| NH4+ [mg · L−1] | 0.02–0.20 | <0.001–0.55 | 0.02–0.05 |
| Mg2+ [mg · L−1] | 3.22–11.86 | 1.28–3.73 | 4.13–5.76 |
| Ca2+ [mg · L−1] | 16.36–47.30 | 26.48–50.27 | 21.92–30.40 |