Abstract

The main goal of this research was to create and test technical solutions that reduce nitrogen oxide emissions in low-capacity pellet boiler. During the research, wood pellets were incinerated in a pellet boiler produced in Latvia with a rated capacity of 15 kW. During the research two NOx emission reduction methods were tested: secondary air supply in the chamber and recirculation of flue gases. Results indicated a drop of NOx concentration only for flue gas recirculation methods. Maximum reduction of 21% was achieved.