Have a personal or library account? Click to login
Dosimetric characterizations of GZP6 60Co high dose rate brachytherapy sources: application of superimposition method Cover

Dosimetric characterizations of GZP6 60Co high dose rate brachytherapy sources: application of superimposition method

Open Access
|Jan 2012

References

  1. Nuclear Power Institute of China (NPIC), 2010, Available at: www.npic.ac.cn/
  2. Ito H. Radiotherapy for cervical cancer: A multi-institutional comparison. Nippon Igaku Hoshasen Gakkai Zasshi 1999; 59: 745-9.
  3. Kim WC, Kim GE, Suh CO, Loh JJK. High versus low dose rate intracavitary irradiation for adenocarcinoma of the uterine cervix. Jpn J Clin Oncol 2001; 31: 432-7.10.1093/jjco/hye098
  4. Papagiannis P, Angelopoulos A, Pantelis E, Sakelliou L, Karaiskos P, Shimizu Y Monte Carlo dosimetry of 60Co HDR brachytherapy sources. Med Phys 2003; 30: 712-21.10.1118/1.1563662
  5. Vranic A. New developments in surgery of malignant gliomas. Radiol Oncol 2011; 45: 159-65.10.2478/v10019-011-0018-3
  6. Richter J, Baier K, Flentje M. Comparison of 60Cobalt and 192Iridium sources in high dose rate afterloading brachytherapy. Strahlenther Onkol 2008; 184: 187-92.10.1007/s00066-008-1684-y
  7. Meisberger LL, Keller R, Shalek RJ. The effective attenuation in water of the gamma rays of 198Au, 192Ir, 137Cs, 226Ra, and 60Co. Radiology 1968; 90: 953-7.10.1148/90.5.953
  8. Sakelliou L, Sakellariou K, Sarigiannis K, Angelopoulos A, Perris A, Zarris G. Dose rate distributions around 60Co, 137Cs, 198Au, 192Ir, 241Am, 125I (models 6702 and 6711) brachytherapy sources and the nuclide 99mTc. Phys Med Biol 1992; 37: 1859-72.10.1088/0031-9155/37/10/004
  9. Nath R, Anderson LL, Luxton G, Weaver KA, Williamson JF, Meigooni AS. Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys 1995; 22: 209-34.10.1118/1.597458
  10. Nath R, Anderson LL, Meli JA, Olch AJ, Stitt JA, Williamson JF. Code of practice for brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group 56. Med Phys 1997; 24: 1557-98.10.1118/1.597966
  11. Mesbahi A, Naseri A. In-air calibration of new high dose rate 60Co brachytherapy sources: results of measurements on a GZP6 brachytherapy afterloading unit. Rep Pract Oncol Radiother 2008; 13: 69-73.10.1016/S1507-1367(10)60084-3
  12. Mesbahi A. Radial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations. Iran J Radiat Res 2008; 5: 181-6.
  13. Naseri A, Mesbahi A. Application of Monte Carlo calculations for validation of atreatment planning system in high dose rate brachytherapy.Rep Pract Oncol Radiother 2009; 14: 200-4.10.1016/j.rpor.2009.12.003
  14. Mowlavi AA, Fornasier MR, de Denaro M. Thyroid volume's influence on energy deposition from 131I calculated by Monte Carlo (MC) simulation. Radiol Oncol 2011; 45: 143-6.10.2478/v10019-011-0008-5342372822933948
  15. Rivard MJ, Coursey BM, DeWerd LA, Hanson WF, Huq MS, Ibbott GS, et al. Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. Med Phys 2004; 31: 633-74.10.1118/1.164604015070264
  16. Karaiskos P, Angelopoulos A, Sakelliou L, Sandilos P, Antypas C, Vlachos L, et al. Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source. Med Phys 1998; 25: 1975-84.10.1118/1.5983719800706
  17. Awan ShB, Dini ShA, Hussain M, Meigooni DS, and Meigooni AS. Cylindrical coordinate-based TG-43U1 parameters for dose calculation around elongated brachytherapy sources. J Appl Clin Med Phys 2008; 9: 123-42.10.1120/jacmp.v9i2.2760572170318714281
  18. Briesmeister JF. MCNP-A general Monte Carlo N-particle transport code, Version 4C. Report LA-13709-M 2000; Los Alamos National Laboratory, NM.
  19. Waters LS. MCNPX User's Manual, Version 2.4.0. Report LA-CP-02-408 2002; Los Alamos National Laboratory.
  20. Bahreyni Toossi MT, Ghorbani M, Mowlavi AA, Taheri M, Layegh M, Makhdoumi Y, et al. Air kerma strength characterization of a GZP6 Cobalt-60 brachytherapy source. Rep Pract Oncol Radiother 2010; 15: 190-4.10.1016/j.rpor.2010.10.002386316124376948
  21. Bahreyni Toossi MT, Abdollahi M, Ghorbani M. Monte Carlo dose calculation of GZP6 60Co stepping source based on a matrix shift technique. Rep Pract Oncol Radiother 2010; 16:10-3.10.1016/j.rpor.2010.11.005386326824376950
  22. Baltas D, Sakelliou L, Zamboglou N. The physics of modern brachytherapy for oncology. Boca Raton, FL: Taylor and Francis Group; 2007. p. 312.10.1201/9781420012422
DOI: https://doi.org/10.2478/v10019-012-0005-3 | Journal eISSN: 1581-3207 | Journal ISSN: 1318-2099
Language: English
Page range: 170 - 178
Published on: Jan 2, 2012
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2012 Mohammad Toossi, Mahdi Ghorbani, Ali Mowlavi, Ali Meigooni, published by Association of Radiology and Oncology
This work is licensed under the Creative Commons License.

Volume 46 (2012): Issue 2 (June 2012)