Dosimetric verification of compensated beams using radiographic film Cover

Dosimetric verification of compensated beams using radiographic film

Open Access
|Jul 2011

References

  1. Han IH, Malviya V, Chuba P, Orton CG, Devi S, Deppe G, et al. Multifractioned HDR brachytherapy with concomitant daily teletherapy for cervical cancer Gynecol Oncol 1996; 63: 71-7.10.1006/gyno.1996.02818898172
  2. Popple RA, Kim RY, Pareek P, Duan J, Shen S, Brezovich IA. Custom step wedge blocking using dynamic multileaf collimation for parametrial pelvic boost irradiation following brachytherapy carcinoma of the cervix. Med Phys 2003; 30: 2699-702.10.1118/1.160451114596307
  3. Jurković S, Žauhar G, Bistrović M, Faj D, Kaliman Z, Smilović Radojčić D. An alternative approach to compensators design for photon beams used in radiotherapy. Nucl Instrum Methods A 2007; 580: 530-3.10.1016/j.nima.2007.05.222
  4. Jurković S, Žauhar G, Faj D, Smilović Radojčić Đ, Švabić M, Radiation therapy photon beams dose conformation according to dose distribution around intracavitary applied brachytherapy sources. Med Dos 2010; 35: 49-52.10.1016/j.meddos.2009.01.00619931015
  5. Bucciolini M, Banci F, Casati M. Verification of IMRT fields by film dosimetry. Med Phys 2004; 31: 161-8.10.1118/1.163109314761032
  6. Bailey DW, Kumaraswamy L, Podgorsak MB. A fully electronic intensity-modulated radiation therapy quality assurance (IMRT QA) process implemented in a network comprised of independent treatment planning, record and verify, and delivery systems. Radiol Oncol 2010; 44: 124-30.10.2478/v10019-010-0017-9342367922933903
  7. Salz H, Wiezorek T, Scheithauer M, Schwedas M, Beck J, Wendt TG. IMRT with Compensators for Head-and-Neck Cancers. Strahlenter Onkol 2005; 181: 665-72.10.1007/s00066-005-1402-y16220406
  8. Srivastava RP, Wagter De C. The value of EDR2 film dosimetry in compensator-based intensity modulated radiation therapy. Phys Med Biol 2007; 52: 449-57.10.1088/0031-9155/52/19/N0317881795
  9. Brahme A, Andreo P. Dosimetry and quality specification of high energy photon beams. Acta Rad Onc 1986; 25: 213-23.10.3109/028418686091364083020890
  10. Seltzer SM. Calculation of photon mass energy-transfer and mass energy-absorption coefficients. Radiat Res 1993; 136: 147-70.10.2307/3578607
  11. Yeo IJ, Wang CC, Burch SE. A filtration method for improving film dosimetry in photon radiation therapy. Med Phys 1997; 24: 1943-53.10.1118/1.598108
  12. Wang X, Spirou S, Lo Sasso T, Stein J, Chui C, Mohan R. Dosimetric verification of intensity-modulated fields. Med Phys 1996; 23: 317-27.10.1118/1.597661
  13. Ju SG, Ahn YC, Huh SJ, Yeo IJ. Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluation. Med Phys 2002; 29: 351-55.10.1118/1.1449493
  14. Rogers DWO, Faddegon BA, Ding GX, Ma CM, We J, Mackie TR. BEAM: a Monte Carlo code to simulate radiotherapy treatment units. Med Phys 1995; 22: 503-24.10.1118/1.597552
  15. Bielayew AF, Rogers DWO. PRESTA: the parameter reduced electron-step transport algorithm for electron Monte Carlo transport. Nucl Instrum Methods B 1987; 18: 165-81.
  16. Ma CM, Reckwerdt P, Holmes M, Rogers DWO, Geiser B. DOSXYZ users manual. National Research, Council of Canada Report PIRS-0509B; 1995.
  17. Lin SY, Chu TC, Lin JP. Monte Carlo simulation of a clinical linear accelerator. App Rad Isotopes 2001; 55: 759-65.10.1016/S0969-8043(01)00130-0
  18. Faj D, Vrtar M, Krajina Z, Jurković S, Margaretić D. Model of total skin electron treatment using the ‘six-dual-field’ technique. Coll Antropol 2003; 27: 713-21.
  19. Verhaegen F, Seuntjens J. Monte Carlo modeling of external radiotherapy photon beams. Phys Med Biol 2003; 48: R107-64.10.1088/0031-9155/48/21/R01
  20. Rivest DRC, Riauka TA, Murtha AD, Fallone BG. Dosimetric implications of two registration based patient positioning methods in prostate image guided radiation therapy (IGRT). Radiol Oncol 2009; 43: 203-12.10.2478/v10019-009-0030-z
  21. Mesbahia A, Reillyb AJ, Thwaites DI. Development and commissioning of a Monte Carlo photon beam model for Varian Clinac 2100EX linear accelerator. Applied Radiation 2006; 64: 656-62.10.1016/j.apradiso.2005.12.012
  22. Ting JY, Davis L. Dose verification for patients undergoing IMRT. Med Dosim 2001; 26: 205-13.10.1016/S0958-3947(01)00059-0
DOI: https://doi.org/10.2478/v10019-011-0020-9 | Journal eISSN: 1581-3207 | Journal ISSN: 1318-2099
Language: English
Page range: 310 - 314
Published on: Jul 20, 2011
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2011 Slaven Jurkovic, Gordana Zauhar, Dario Faj, Deni Radojcic, Manda Svabic, Mladen Kasabasic, Ana Diklic, published by Association of Radiology and Oncology
This work is licensed under the Creative Commons License.

Volume 45 (2011): Issue 4 (December 2011)