Have a personal or library account? Click to login
Analysis of peripheral artery velocity tracing in a porcine model Cover

Analysis of peripheral artery velocity tracing in a porcine model

Open Access
|Mar 2011

References

  1. Nam KH, Paeng DG, Choi MJ, Shung KK. Ultrasonic observation of blood disturbance in a stenosed tube: effcects of flow acceleration and turbulence downstream. Ultrasound Med Biol 2008; 34: 114-22.10.1016/j.ultrasmedbio.2007.07.009
  2. Haruguchi H, Teraoka S. Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review. J Artif Organs 2003; 6: 227-35.10.1007/s10047-003-0232-x
  3. Ariff B, Stanton A, Barratt D, Augst A, Glor F, Poulter N, et al. Comparison of the effects of antihypertensive treatment with angiotensin II blockade and beta-blockade on carotid wall structure and haemodynamics: protocol and baseline demographics. J Renin Angiotensin Aldosterone Syst 2002; 3: 116-22.10.3317/jraas.2002.012
  4. Poepping TL, Nikolov HN, Rankin RN, Lee M, Holdsworth DW. An in vitro system for Doppler ultrasound flow studies in the stenosed carotid artery bifurcation. Ultrasound Med Biol 2002; 28: 495-506.10.1016/S0301-5629(02)00479-9
  5. Stein PD, Sabbah HN. Measured turbulence and its effect on thrombus formation. Circ Res 1974; 35: 608-14.10.1161/01.RES.35.4.608
  6. Grigioni M, Daniele C, Morbiducci U, D'Avenio G., Di Benedetto G., Barbaro V. Morphological analysis of in vivo velocity field in the alteration of the vasomotor tone. Int J Artif Organs 2004; 27: 868-81.10.1177/039139880402701008
  7. Meng QX, Yang B. The haemodynamics caused by arterial stenosis. Chin J Med Imaging Technol 2008; 24: 297-300.
  8. Caluk J, Osmanovic E, Barakovic F, Kusljugic Z, Terzic I, Caluk S, et al. Direct coronary stenting in reducing radiation and radiocontrast consumption. Radiol Oncol 2010; 44: 153-7.10.2478/v10019-010-0016-x
  9. Gjikolli B, Hadžihasanović B, Jaganjac S, Herceglija E, Nikšić M, Hadzimehmedagić A, et al. Treatment of complicated case with subclavia steal syndrome and stenosis of common iliac artery. Radiol Oncol 2008; 42: 1-12.10.2478/v10019-007-0032-7
  10. Shortland AP, Cochrane T. Doppler spectral waveform generation in vitro: an aid to diagnosis of vascular disease. Ultrasound Med Biol 1989; 15:737-48.10.1016/0301-5629(89)90114-2
  11. Khir AW, Parker KH. Wave intensity in the ascending aorta: effects of arterial occlusion. J Biomechanics 2005; 38: 647-55.10.1016/j.jbiomech.2004.05.03915713284
  12. Hutchison KJ, Karpinski E. Stability of flow patterns in the in vivo poststenotic velocity field. Ultrasound Med Biol 1988; 14: 269-75.10.1016/0301-5629(88)90092-0
  13. Pawson P, Nolan AM, Reid J, Boyd JS, Paterson C. Changes in the Doppler waveform of the ovine femoral artery following infusion of vasoactive agents: a preliminary study. Res Vet Sci 2002; 73: 215-21.10.1016/S0034-5288(02)00009-7
  14. Yilmaz C, Erkan N, Arslan M, Yildirim Y, Kalaycioglu S. Budd-Chiari syndrome associated with liver hydatid disease: retrospective evaluation of color Doppler US findings with emphasis on intrahepatic venous collateralization. Radiol Oncol 2009; 43: 225-32.10.2478/v10019-009-0036-6
  15. Fukuhara T, Hida K. Pulsatility index at the cervical internal carotid artery as a parameter of microangiopathy in patients with type 2 diabetes. J Ultrasound Med 2006; 25: 599-605.10.7863/jum.2006.25.5.599
  16. Ohta Y, Fujii K, Arima H, Matsumura K, Tsuchihashi T, Tokumoto M, et al. Increased renal resistive index in atherosclerosis and diabetic nephropathy assessed by Doppler sonography. J Hypertens 2005; 23: 1905-11.10.1097/01.hjh.0000181323.44162.01
  17. Jorgensen JJ, Stranden E, Gjolberg T. The femoral arterial flow velocity pattern in patients with aortoiliac atherosclerosis. Studies with a pulsed Doppler ultrasound flowmeter. Acta Chir Scand 1986; 152: 257-61.
  18. Staub D, Canevascini R, Huegli RW, Aschwanden M, Thalhammer C, Imfeld S, et al. Best duplex-sonographic criteria for the assessment of renal artery stenosis—correlation with intra-arterial pressure gradient. Ultraschall Med 2007; 28: 45-51.10.1055/s-2007-962881
  19. Cardoso CM, Xavier SS, Lopez GE, Brunini TM. Direct duplex scanning parameters in the diagnosis of renal artery stenosis: a study to validate and optimize cut-off points. Arq Bras Cardiol 2006; 87: 321-8.
  20. Kawarada O, Yokoi Y, Takemoto K, Morioka N, Nakata S, Shiotani S. The performance of renal duplex ultrasonography for the detection of hemodynamically significant renal artery stenosis. Catheter Cardiovasc Interv 2006; 68: 311-8.10.1002/ccd.20837
  21. Smet AA, Ermers EJ, Kitslaar PJ. Duplex velocity characteristics of aortoiliac stenoses. J Vasc Surg 1996; 23: 628-36.10.1016/S0741-5214(96)80043-7
  22. Miralles M, Cairols M, Cotillas J, Giménez A, Santiso A. Value of Doppler parameters in the diagnosis of renal artery stenosis. J Vasc Surg 1996; 23: 428-35.10.1016/S0741-5214(96)80007-3
  23. Cooperberg E. Ultrasound Doppler spectral analysis in the diagnosis of occlusive lesions of the carotid arteries. Ultrasound Med Biol 1992; 18: 421-5.10.1016/0301-5629(92)90050-K
  24. Leng GC, Whyman MR, Donnan PT, Ruckley CV, Gillespie I, Fowkes FG, et al. Accuracy and reproducibility of duplex ultrasonography in grading femoropopliteal stenoses. J Vasc Surg 1993; 17: 510-7.10.1016/0741-5214(93)90151-B
  25. Choi JY, Lee JY, Lee JM, Kim SH, Lee MW, Han JK, et al. Routine intraoperative Doppler sonography in the evaluation of complications after living-related donor liver transplantation. J Clin Ultrasound 2007; 35: 483-90.10.1002/jcu.20384
  26. Hoff WV. Erratum in: Pediatr Radiol. Pediatr Radiol 2007; 37: 310-2.
  27. Kriaa S, Zbidi M, Hafsa C, Brahem R, Majdoub S, Golli M, et al. Tardus-parvus Doppler waveform in the renal arteries of an adult patient suggesting aortic coarctation. J Clin Ultrasound 2006; 34: 458-60.10.1002/jcu.20267
  28. Richardson D, Foster J, Davison AM, Irving HC. Parvus tardus waveform suggesting renal artery stenosis-remember the more proximal stenosis. Nephrol Dial Transplant 2000; 15: 539-43.10.1093/ndt/15.4.539
  29. Hartmann A, Mast H, Thompson JL, Sia RM, Mohr JP. Transcranial Doppler waveform blunting in severe extracranial carotid artery stenosis. Cerebrovasc Dis 2000; 10: 33-8.10.1159/000016022
  30. O'Boyle MK, Vibhakar NI, Chung J, Keen WD, Gosink BB. Duplex sonography of the carotid arteries in patients with isolated aortic stenosis: imaging findings and relation to severity of stenosis. Am J Roentgenol 1996; 166: 197-202.10.2214/ajr.166.1.8571875
  31. Bagi P, Sillesen H, Hansen HJ. Quantitative Doppler ultrasound evaluation of occlusive arterial disease in the lower limb. Eur J Vasc Surg 1988; 2: 409-15.10.1016/S0950-821X(88)80021-5
  32. de Morais Filho D, Miranda F Jr, Del Carmen Janeiro Peres M, Barros N Jr, Buriham E, Salles-Cunha SX. Segmental waveform analysis in the diagnosis of peripheral arterial occlusive diseases. Ann Vasc Surg 2004; 18: 714-24.10.1007/s10016-004-0086-615599630
  33. Fontcuberta J, Flores A, Langsfeld M, Orgaz A, Cuena R, Criado E, et al. Screening algorithm for aortoiliac occlusive disease using duplex ultrasonography-acquired velocity spectra from the distal external iliac artery. Vascular 2005; 13: 164-72.10.1258/rsmvasc.13.3.16415996374
  34. Steinman DA, Poepping TL, Tambasco M, Rankin RN, Holdsworth DW. Flow patterns at the stenosed carotid bifurcation: Effect of concentric versus eccentric stenosis. Ann Biomed Eng 2000; 28: 415-23.10.1114/1.27910870898
  35. Stergiopulos N, Spiridon M, Pythoud F, Meister JJ. On the wave transmission and reflection properties of stenoses. J Biomech 1996; 29: 31-8.10.1016/0021-9290(95)00023-2
  36. Higgins D, Santamore WP, Walinsky P, Nemir P Jr. Hemodynamics of human arterial stenoses. Inter J Cardiol 1985; 8: 177-92.10.1016/0167-5273(85)90286-4
  37. Ahmed SA, Giddens DP. Flow disturbance measurements through a constricted tube at moderate Reynolds numbers. ERS J Biomech 1983; 16: 955-63.10.1016/0021-9290(83)90096-9
  38. Hutchison KJ, Campbell JD, Karpinski E. Decreased poststenotic flow disturbance during drag reduction by polyacrylamide infusion without increased aortic blood flow. Microvasc Res 1989; 38: 102-9.10.1016/0026-2862(89)90019-8
  39. Baker AR, Prytherch DR, Evans DH, Bell PR. Characterisation of aorto-iliac arterial stenoses in terms of pressure and flow. Cardiovasc Res 1985; 19: 559-66.10.1093/cvr/19.9.559
  40. Nielsen TG, Djurhuus C, Pedersen EM, Laustsen J, Hasenkam JM, Schroeder TV. Arteriovenous fistulas aggravate the hemodynamic effect of vein bypass stenoses: An in vitro study. J Vascul Surg 1996; 24: 1043-9.10.1016/S0741-5214(96)70051-4
  41. Shi Y, Mei SC. Medical animal experiment practical manual. 1st ed. Beijing: China Agriculture Press; 2002. p. 233-9.
  42. Rice J, Philbin N, McGwin G, Arnaud F, Johnson T, Flournoy WS, et al. Bovine polymerized hemoglobin versus Hextend resuscitation in a swine model of severe controlled hemorrhagic shock with delay to definitive care. Shock 2006; 26: 302-10.10.1097/01.shk.0000226338.48033.c216912657
  43. Draney MT, Arko FR, Alley MT, Markl M, Herfkens RJ, Pelc NJ, et al. Quantification of vessel wall motion and cyclic strain using cine phase contrast MRI: in vivo validation in the porcine aorta. Magn Reson Med 2004; 52: 286-95.10.1002/mrm.2013715282810
  44. Yang BF. Pharmacology. 7st ed. Beijing: People's Health Publishing House; 2008. p. 89-91.
DOI: https://doi.org/10.2478/v10019-011-0004-9 | Journal eISSN: 1581-3207 | Journal ISSN: 1318-2099
Language: English
Page range: 82 - 90
Published on: Mar 15, 2011
Published by: Association of Radiology and Oncology
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2011 Qingxin Meng, Weiwei Ding, Bin Yang, Ninghua Fu, Guangming Lu, published by Association of Radiology and Oncology
This work is licensed under the Creative Commons License.

Volume 45 (2011): Issue 2 (June 2011)