Implementing of the offline setup correction protocol in pelvic radiotherapy: safety margins and number of images
By: Mladen KasabaŠić, Dario Faj, Nenad Belaj, Zlatan Faj and Ilijan TomaŠ
Open Access
|Apr 2007References
- Park W, Huh SJ, Lee JE, Han Y, Shin E, Chan Y, et al. Variation of small bowel sparing with small bowel displacement system according to the physiological status of the bladder during radiotherapy for cervical cancer.2005;: 645-51.
- Ghosh K, Padilla LA, Murray KP, Downs LS, Carson LF, Dusenbery KE. Using a belly bord device to reduce the small bowel volume within pelvic radiation fields in woman with postoperatively treated cervical carcinoma.2001;: 271-75.
- Olofsen-van Acht M, van den Berg H, Quint S, de Boer H, Seven M, van Somsen de Koste J, et al. Reduction of irradiated small bowel volume and accurate patient positioning by use of a bellyboard device in pelvic radiotherapy of gynecological cancer patients.2001;: 87-93.
- Hollenhorst H, Schaffer M, Romano M, Reiner M, Siefert A, Schaffer P, et al. Optimized radiation of pelvic volumes in the clinical settings by using a novel bellyboard with integrated gonadal shielding.2004;: 173-8.
- Huh SJ, Park W, Ju SG, Lee JE, Han Y. Small-bowel displacement system for the sparing of small bowel in three-dimensional conformal radiotherapy for cervical cancer.2004;: 467-73.
- Weiss E, Richter S, Hess CF. Radiation therapy of the pelvic and paraaortic lymph nodes in cervical carcinoma: a prospective three-dimensional analysis of patient positioning and treatment technique.2003;: 41-9.
- Stroom JC, Olofsen-van Acht MJJ, Quint S, Seven M, De Hoog M, Creutzberg CL, De Boer HCJ, et al. On-line set-up corrections during radiotherapy of patients with gynecologic tumors.2000;: 499-506.
- Cazzaniga LF, Frigerio M. Errors in positioning the patient during transcutaneous radiotherapy of the pelvis.1997;: 664-70.
- Quint S, de Boer HCJ, van Sörnsen de Koste JR, Heijmen BJM, Olofsen van Acht MJJ. Set-up verification of cervix cancer patients treated with long treatment fields; implications of a non-rigid bony anatomy.2001;: 25-9.
- Kragelj B. Setup error and its effect on safety margin in conformal radiotherapy of the prostate.2005;: 211-7.
- Ludbrook JS, Greer PB, Blood P, D'Yachkova Y, Coldman A, Beckham WA, et al. Correction of systematic setup errors in prostate radiation therapy: how many images to perform?2005;: 76-84.
- van Herk M, Remeijer P, Rasch C, Lebesque JV. The probability of correct target dosage: Dose population histograms for deriving treatment margins in radiotherapy.2000;: 1121-35.
- Bortfeld T, Van Herk M, Jiang SB. When should systematic patient positioning errors in radiotherapy be corrected?2000;: 297-302.
- Booth JT. Modelling the impact of treatment uncertainties in radiotherapy. PhD thesis. Adelaide: University of Adelaide, Australia; 2002.
- Haslam JJ, Lujan AE, Mundt AJ, Bonta DV, Roeske JC. Setup errors in patients treated with intensity-modulated whole pelvic radiation therapy for gynecological malignancies,2005;: 36-42.
Language: English
Page range: 48 - 55
Published on: Apr 30, 2007
Published by: Association of Radiology and Oncology
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year
Related subjects:
© 2007 Mladen KasabaŠić, Dario Faj, Nenad Belaj, Zlatan Faj, Ilijan TomaŠ, published by Association of Radiology and Oncology