Skip to main content
Have a personal or library account? Click to login
Measurement of Head Scatter Factor for Linear Accelerators using Indigenously Designed Columnar Mini Phantom Cover

Measurement of Head Scatter Factor for Linear Accelerators using Indigenously Designed Columnar Mini Phantom

Open Access
|Feb 2012

References

  1. Biggs P. J, Ling C. C. Electron as the cause of the observe dshift with field size in high energy beams. Med Phys. 1979; 6: 291-295.
  2. Biggs P J, Russell M. D. An investigation into the presence of secondary electrons in megavoltage photon beams. Phys Med Biol. 1983; 28: 1033-1043.
  3. Bjarngard B. E, Vadash P. Analysis of central-axis doses for high energy x-rays. Med Phys. 1995; 22: 1191-1195.
  4. Ding G. X. An investigations of accelerator head scatter and output factor in air. Med Phys. 2004; 31: 2527-2533.
  5. Dutreix A, Bjarngard B. E, Bridier A, Mijnheer B, Shaw J.E, Svensson H. Monitor unit calculation for high energy photon beams. The Netherlands, ESTRO and Garant Publishers, 1997: 101-104.
  6. Heukelom S, Lanson J. H, Mijnheer B. J. Wedge factor constituents of higher-energy photon beams: head and phantom scatter dose components. Radiother Oncol. 1994; 32: 73-83.
  7. Holt J. G, Laughlin J. S, Moroney J. P. The extension of the concept of tissue-air ratios (TAR) to high-energy x-ray beams. Radiology. 1970; 96: 437-446
  8. Johns H. E, Cunningham J. R. The Physics of Radiology. 4edition. Charles C. Thomas, Springfield. 1983: 336-381.
  9. Jursinic P A, Measurement of head scatter factors of linear accelerators with columnar miniphantoms. Med Phys. 2006; 33: 1720-1728.
  10. Karzmark C J, Deubert A, Loevinger R. Tissue-phantom ratios—An aid to treatment planning. Brit J Radiol. 1965; 38: 158-159.
  11. Khan F M, Sewchand W, Lee J, Williamson J F. Revision of tissue-maximum ratio and scatter-maximum ratio concepts for cobalt 60 and higher energy x-ray beams. Med Phys. 1980; 7: 230-237.
  12. Luxton G, Astrahan M A. Characteristics of high energy photon beam of a 25 MV accelerator. Med Phys. 1988; 15: 82-87.
  13. Luxton G, Astrahan M A, Output factor constituents of a high energy photon beam. Med Phys. 1988; 15: 88-91.
  14. Mackie T R, Scrimger J W. Contamination of a 15-MV photon beam by electrons and scattered photons. Radiology. 1982; 144: 403-409.
  15. McKenzie A L, Stevens P H. Twenty-five years of MTRP—A theoretical and experimental analysis. Phys Med Biol. 1995; 40: 17-29.
  16. Sjogren R, Karlsson M. Electron contamination in clinical high energy photon beams. Med Phys. 1996; 23: 1873-1881.
  17. Tatcher M, Bjarngard B E. Head-scatter factors in rectangular photon fields. Med Phys. 1993; 20: 205-206.
  18. Van Gasteren J J M, Heukelom S, Jager H N, Mijnheer B J, van Kleffens H J, van der Laarse R. et al. Determination and use of scatter correction factors of megavoltage photon beams. Netherlands Commission on Radiation Dosimetry. NCS Report No. 12. 1998.
  19. Venselaar J, Heukelom S, Jager N, Mijnheer B, van der Laarse R, van Gasteren H, et al. Effect of electron contamination on scatter correction factors for photon beam dosimetry. Med Phys. 1999; 26: 2099-2106.
  20. Weber L, Nilsson P, Ahnesjo A. Build-up cap materials for measurements of photon head-scatter factors, Phys Med Biol. 1997; 42: 1875-1886.
  21. Zhu T C, Lam K L, Li X A, Charlie Ma C-M, Palta J R, et al. Report of AAPM Therapy Physic Committee task Group 74: In-air output ratio, S, for megavoltage photon beams. Med Phys. 2009; 36: 5261-5291.
DOI: https://doi.org/10.2478/v10013-011-0002-7 | Journal eISSN: 1898-0309 (formerly 1425-4689) | Journal ISSN: 1425-4689
Language: English
Page range: 13 - 25
Published on: Feb 7, 2012
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services

© 2012 Murugan Appasamy, Sidonia Xavier, Thayalan Kuppusamy, Ramasubramanian Velayudham, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons License.