Have a personal or library account? Click to login
IMRT versus 3D-CRT for thyroid cancer Cover

Abstract

A 3D-CRT involving a 4-field (5-field, 6-field, etc.) technique (photon and electron beams) and an alternative IMRT 7-field technique with 6 MV photon fields for thyroid cancer were compared. The IMRT allows reduction in the dose to the spinal cord of about 12 Gy and permits better coverage of the target volume with smaller standard deviation (average 4.65% for 3D-CRT as compared with 1.81% for IMRT). The time needed to prepare therapy (TPS, dosimetry, preparing boluses and electron aperture) and the session time are about the same for both techniques.

DOI: https://doi.org/10.2478/v10013-008-0013-1 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 151 - 162
Published on: Apr 14, 2009
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2009 Marta Gizynska, Anna Zawadzka, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons License.

Volume 14 (2008): Issue 3 (September 2008)