Have a personal or library account? Click to login
Analysis of Calibration Coefficients of Plane-Parallel Markus Type Ionization Chambers Calibrated in Co-60 and Electron Beams Cover

Analysis of Calibration Coefficients of Plane-Parallel Markus Type Ionization Chambers Calibrated in Co-60 and Electron Beams

Open Access
|Dec 2008

References

  1. Almond PR, Attix RH, Humphries LJ, Kubo H, Nath R, Goetsch S, Rogers DWO. The calibration and use of plane parallel ionisation chambers for dosimetry of electron beams: An extension of the 1983 AAPM protocol report of AAPM Radiation Therapy Committee Task Group No 39. Med Phys 1994; 21(8): 1251-1260.10.1118/1.5973597799867
  2. IAEA. The use of plane parallel ionisation chambers in high energy electron and photon beams. An International Code of Practice for Dosimetry. Technical Reports Series. Vienna, 1997; No TRS 381.
  3. Dąbrowski R. Dozymetria z zastosowaniem komór jonizacyjnych. In: Pawlicki G, Pałko T, Golnik N, Gwiazdowska B, Królicki L, redaktorzy. Fizyka medyczna. Warszawa: Akademicka Oficyna Wydawnicza Exit; 2002. p. 209-262.
  4. Gerbi BJ, Khan FM. Measurement of dose in build-up region using fixed - separation plane-parallel ionisation chambers. Med Phys 1990; 17(1): 17-26.10.1118/1.5965222106611
  5. Mellenberg D. Determination of build-up region over-response corrections for Markus-type chamber. Med Phys 1990; 17(6): 1041-1044.10.1118/1.5965792280733
  6. Ross CK, Shortt KR. The effect of waterproofing sleeves on ionisation chamber response. Phys Med Biol 1992; 37: 1403-1411.10.1088/0031-9155/37/6/017
  7. IAEA. Absorbed Dose Determination in External Beam Radiotherapy. An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water. Technical Reports Series. Vienna, 2000; No TRS 398.
  8. Morawska M. Testy kontroli jakości dawkomierzy z komorami płaskimi. Nowotwory 2000; 50(3): 294-302.
  9. Boag JW, Currant J. Current collection and ionic recombination in small cylindrical ionisation chambers exposed to pulsed radiation. Brit J Radiol 1980; 53: 471-478.10.1259/0007-1285-53-629-4717388281
  10. IAEA. Absorbed dose determination in photon and electron beams. An international code of practice. Technical Reports Series, second edition, Vienna, 1997; No TRS 277.
DOI: https://doi.org/10.2478/v10013-007-0015-4 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 163 - 174
Published on: Dec 30, 2008
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2008 Wojciech Bulski, Piotr Ulkowski, Barbara Gwiazdowska, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons License.

Volume 13 (2007): Issue 3 (September 2007)