Skip to main content
Have a personal or library account? Click to login
System matrix computation for iterative reconstruction algorithms in SPECT based on direct measurements Cover

System matrix computation for iterative reconstruction algorithms in SPECT based on direct measurements

Open Access
|Mar 2011

References

  1. Autret, D., Bitar, A., Ferrer, L., Lisbona, A. and Bardies, M. (2005). Monte Carlo modeling of gamma cameras for I-131 imaging in targeted radiotherapy,(1): 77-84.
  2. Borys, D., Panek, R., Gorczewski, K., d'Amico, A., Steinhof, K. and Psiuk-Maksymowicz, K. (2006). Evaluation of SPECT-CT image fusion quality control,(4): 79-90.
  3. Bruyant, P. P. (2002). Analytic and iterative reconstruction algorithms in SPECT,(10): 1343-1358.
  4. Chang, L. T. (1978). A method for attenuation correction in radionuclide computed tomography,(1): 638-643.
  5. Cherry, S. R., Sorenson, J. A. and Phelps, M. A. (2003)., Saunders/Elsevier Science, Philadelphia, PA.
  6. Formiconi, A. R., Pupi, A. and Passeri, A. (1989). Compensation of spatial system response in SPECT with conjugate gradient reconstruction technique,(1): 69-84.
  7. Gilland, D. R., Jaszczak, R. J., Wang, H., Turkington, T. G., Greer, K. L. and Coleman, R. E. (1994). A 3D model of non-uniform attenuation and detector response for efficient iterative reconstruction in SPECT,(3): 547-561.
  8. Graham, L. S., Fahey, F. H., Madsen, M. T., van Aswegen, A. and Yester, M. V. (1995). Quantitation of SPECT performance: Report of Task Group 4, Nuclear Medicine Committee,(4): 401-409.
  9. Hubbell, J. H. and Seltzer, S. M. (n.d.). Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients
  10. Hudson, H. M. and Larkin, R. S. (1994). Accelerated image reconstruction using ordered subsets of projection data,(4): 601-609.
  11. Ichihara, T., Ogawa, K., Motomura, N., Kubo, A. and Hashimoto, S. (1993). Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT,(12): 2216-2221.
  12. Lazaro, D., El Bitar, Z., Breton, V., Hill, D. and Buvat, I. (2005). Fully 3D Monte Carlo reconstruction in SPECT: A feasibility study,(16): 3739-3754.
  13. Liang, Z., Turkington, T. G., Gilland, D. R., Jaszczak, R. J. and Coleman, R. E. (1992). Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions,(3): 587-603.
  14. Loudos, G. K. (2008). An efficient analytical calculation of probability matrix in 2D SPECT,(2): 83-94.
  15. Rafecas, M., Böning, G., Pichler, B. J., Lorenz, E., Schwaiger, M. and Ziegler, S. I. (2004). Effect of noise in the probability matrix used for statistical reconstruction of PET data,(1): 149-156.
  16. Shepp, L. A. and Vardi, Y. (1982). Maximum likelihood reconstruction for emission tomography,(2): 113-122.
  17. Vandenberghe, S., D'Asseler, Y., Van de Walle, R., Kauppinen, T., Koole, M., Bouwens, L., Van Laere, K., Lemahieu, I. and Dierckx, R. A. (2001). Iterative reconstruction algorithms in nuclear medicine,(2): 105-111.
  18. Zaidi, H. (2006)., Springer, New York, NY.
  19. Zeng, G. L. (2001). Image reconstruction—A tutorial,(2): 97-103.
DOI: https://doi.org/10.2478/v10006-011-0014-1 | Journal eISSN: 2083-8492 | Journal ISSN: 1641-876X
Language: English
Page range: 193 - 202
Published on: Mar 28, 2011
Published by: University of Zielona Góra
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2011 Damian Borys, Katarzyna Szczucka-Borys, Kamil Gorczewski, published by University of Zielona Góra
This work is licensed under the Creative Commons License.