Have a personal or library account? Click to login
Monitoring of Chlorine Concentration in Drinking Water Distribution Systems Using an Interval Estimator Cover

Monitoring of Chlorine Concentration in Drinking Water Distribution Systems Using an Interval Estimator

Open Access
|Jul 2007

Abstract

This paper describes the design of an interval observer for the estimation of unmeasured quality state variables in drinking water distribution systems. The estimator utilizes a set bounded model of uncertainty to produce robust interval bounds on the estimated state variables of the water quality. The bounds are generated by solving two differential equations. Hence the numerical efficiency is sufficient for on-line monitoring of the water quality. The observer is applied to an exemplary water network and its performance is validated by simulations.

DOI: https://doi.org/10.2478/v10006-007-0019-y | Journal eISSN: 2083-8492 | Journal ISSN: 1641-876X
Language: English
Page range: 199 - 216
Published on: Jul 17, 2007
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2007 Rafał Łangowski, Mietek Brdys, published by University of Zielona Góra
This work is licensed under the Creative Commons License.

Volume 17 (2007): Issue 2 (June 2007)