Skip to main content
Have a personal or library account? Click to login
Precision and bias evaluation of three different triglyceride assays: Discrepant bias per the CLSI EP15-A3 and EP09-A3 guidelines Cover

Precision and bias evaluation of three different triglyceride assays: Discrepant bias per the CLSI EP15-A3 and EP09-A3 guidelines

Open Access
|Apr 2026

References

  1. Oh RC, Trivette ET, Westerfield KL. Management of Hypertriglyceridemia: Common Questions and Answers. Am Fam Physician. 2020 Sep 15;102(6):347-354.
  2. Romaszko J, Gromadziński L, Buciński A. Friedewald formula may be used to calculate nonHDL-C from LDL-C and TG. Front Med (Lausanne). 2023 Sep 14;10:1247126. DOI: 10.3389/fmed.2023.1247126
  3. Ginsberg HN, Rosenson RS, Hovingh GK, Letierce A, Samuel R, Poulouin Y, et al. LDLC calculated by Friedewald, Martin-Hopkins, or NIH equation 2 versus beta-quantification: pooled alirocumab trials. J Lipid Res. 2022 Jan;63(1):100148. DOI: 10.1016/j.jlr.2021.100148
  4. Sampson M, Ling C, Sun Q, Harb R, Ashmaig M, Warnick R, et al. A New Equation for Calculation of Low-Density Lipoprotein Cholesterol in Patients With Normolipidemia and/or Hypertriglyceridemia. JAMA Cardiol. 2020 May 1;5(5):540-548. DOI: 10.1001/jamacardio.2020.0013
  5. Ertürk Zararsız G, Bolat S, Cephe A, Kochan N, Yerlitaş Sİ, Doğan HO, et al. Validation of Friedewald, Martin-Hopkins and Sampson low-density lipoprotein cholesterol equations. PLoS One. 2022 May 13;17(5):e0263860. DOI: 10.1371/journal.pone.0263860
  6. Abbott Triglyceride for use with Architect reagent user manual, Revision: June 2018. Abbott Laboratories Abbott Park, IL 60064 USA.
  7. Abbott Triglyceride 2 for use with Architect reagent user manual, Revision: March 2021. Abbott Ireland Diagnostics Division Lisnamuck, Longford Co. Longford Ireland.
  8. Archem Sağlık Sanayi ve Ticaret AŞ. Archem Diagnostics Triglycerides reagent: user manual. Revision February 2022. Istanbul, Turkey.
  9. Clinical and Laboratory Standards Institute. EP09-A3 Measurement Procedure Comparison and Bias Estimation Using Patient Samples; Approved Guideline - Third Edition. Wayne, PA: CLSI, 2013 .
  10. Clinical and Laboratory Standards Institute. User verification of precision and estimation of bias; Approved guideline - 3rd ed. CLSI document EP15-A3. Wayne, PA: CLSI, 2014.
  11. Pum J. A practical guide to validation and verification of analytical methods in the clinical laboratory. Adv Clin Chem. 2019;90:215-281. DOI: 10.1016/bs.acc.2019.01.006
  12. Aarsand AK, Fernandez-Calle P, Webster C, Coskun A, Gonzalez-Lao E, Diaz-Garzon J, et al. The EFLM Biological Variation Database [Internet]. Available from: https://biologicalvariation.eu/ Accessed November 30, 2024.
  13. Technopath Clinical Diagnostics Multichem S Plus (Assayed), July 2023. Techno-Path Manufacturing LtD. Fort Henry Business Park, Ballina Co. Tipperary Ireland.
  14. Coskun A. Bias in Laboratory Medicine: The Dark Side of the Moon. Ann Lab Med. 2024 Jan 1;44(1):6-20. doi: 10.3343/alm.2024.44.1.6. DOI: 10.3343/alm.2024.44.1.6
  15. Yang X, Chen Q, Pan Z, Cheng J, Zheng W, Liang Y, et al. Application of Patient-Based Real-Time Quality Control Based on Artificial Intelligence Monitoring Platform in Continuously Quality Risk Monitoring of Down Syndrome Serum Screening. J Clin Lab Anal. 2024 Mar;38(5):e25019. DOI: 10.1002/jcla.25019
  16. Archem Sağlık Sanayi ve Tic A.Ş. Multichem S Plus for ARCHITECT Chemistry Systems. Ref No: 05P78-10/11. Technopath Lot No: 13910231-2. Istanbul, Turkey.
  17. Bozkurt Yavuz H, Karahan S, Yaman H, Örem A, Aliyazıcıoğlu Y. Two approaches for measurement uncertainty estimation: which role for bias? Complete blood count experience. Turkish Journal of Biochemistry. 2021;46(6): 639-645. DOI: 10.1515/tjb-2020-0357
  18. Ozcelik F, Yiginer O, Serdar MA, Kurt İ, Öztosun M, Arslan E, et al. Comparison of three methods for measurement of HbA1c. Turk J Biochem. 2010;35(4);344-349.
  19. Giavarina D. Understanding Bland Altman analysis. Biochem Med (Zagreb). 2015 Jun 5;25(2):141-51. DOI: 10.11613/BM.2015.015
  20. Fokkema MR, Herrmann Z, Muskiet FA, Moecks J. Reference change values for brain natriuretic peptides revisited. Clin Chem. 2006 Aug;52(8):1602-3. DOI: 10.1373/clinchem.2006.069369
  21. Serdar CC, Cihan M, Yücel D, Serdar MA. Sample size, power and effect size revisited: simplified and practical approaches in pre-clinical, clinical and laboratory studies. Biochem Med (Zagreb). 2021 Feb 15;31(1):0105 DOI: 10.11613/BM.2021.010502
DOI: https://doi.org/10.2478/rrlm-2026-0011 | Journal eISSN: 2284-5623 | Journal ISSN: 1841-6624
Language: English
Page range: 103 - 110
Submitted on: Dec 28, 2025
Accepted on: Feb 5, 2026
Published on: Apr 24, 2026
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2026 Hatice Bozkurt Yavuz, Soycan Tüner, published by Romanian Association of Laboratory Medicine
This work is licensed under the Creative Commons Attribution 4.0 License.