Have a personal or library account? Click to login

References

  1. Simundic AM, Cornes M, Grankvist K, Lippi G, Nybo M, Kovalevskaya S, et al. Survey of national guidelines, education and training on venous blood collection in 28 European countries: an original report by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PA). Clin Chem Lab Med 2013;51:1585-93. DOI: 10.1515/cclm-2013-0283
  2. Lippi G, Cervellin G, Mattiuzzi C. Critical review and metaanalysis of spurious hemolysis in blood samples collected from intravenous catheters. Biochem Med (Zagreb) 2013;23:193-200. DOI: 10.11613/BM.2013.022
  3. Mrazek C, Simundic AM, Wiedemann H, Krahmer F, Felder TK, Kipman U, et al. The relationship between vacuum and hemolysis during catheter blood collection: a retrospective analysis of six large cohorts. Clin Chem Lab Med 2017;55:1129-34. DOI: 10.1515/cclm-2016-0940
  4. Heiligers-Duckers C, Peters NA, van Dijck JJ, Hoeijmakers JM, Janssen MJ. Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters. Clin Biochem 2013;46:1142-4. DOI: 10.1016/j.clinbiochem.2013.04.005
  5. ISO/TS 15189:2012 Medical laboratories - Requirements for quality and competence.
  6. ISO/TS 20658:2017 Medical laboratories - Requirements for collection, transport, receipt, and handling of samples.
  7. Simundic AM, Church S, Cornes MP, Grankvist K, Lippi G, Nybo M, et al. Compliance of blood sampling procedures with the CLSI H3-A6 guidelines: an observational study by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PRE). Clin Chem Lab Med 2015;53:1321-31. DOI: 10.1515/cclm-2014-1053
  8. Clinical Laboratory Standards Institute. GP41: procedures for collection of diagnostic blood specimens by venipuncture; approved guideline, 7th ed. CLSI document GP41. Wayne, PA: Clinical and Laboratory Standards Institute, 2007.
  9. World Heath Organization. WHO guidelines on drawing blood. http://whqlibdoc.who.int/publications/2010/9789241599221_eng.pdf. Accessed: 11 Jan 2013.
  10. Guyatt GH, Oxman AD, Kunz R, Falck-Ytter Y, Vist GE, Liberati A, et al. Going from evidence to recommendations. Br Med J 2008;336:1049-51. DOI: 10.1136/bmj.39493.646875.AE
  11. http://www.uptodate.com/home/gradingguide#gradingrecomendations. Accessed: June 2018.
  12. EFLM Procedure Manual v1.15, April 2017; Accessed: 9 Jun 2018, under Official Documents/Rules and regulations at: https://www.eflm.eu/site/page/a/1056.
  13. American College of O, Gynecologists Committee on Health Care for Underserved W, Committee on Patient S, Quality I. ACOG Committee Opinion No. 587: effective patient-physician communication. Obstet Gynecol 2014;123:389-93. DOI: 10.1097/01.AOG.0000443279.14017.12
  14. Ha JF, Longnecker N. Doctor-patient communication: a review. Ochsner J 2010;10:38-43.
  15. France CR, France JL, Himawan LK, Stephens KY, Frame-Brown TA, Venable GA, et al. How afraid are you of having blood drawn from your arm? A simple fear question predicts vasovagal reactions without causing them among high school donors. Transfusion 2013;53:315-21. DOI: 10.1111/j.1537-2995.2012.03726.x
  16. Simundic AM, Nikolac N, Guder W. Preanalytical variation and preexamination processes. In: Rifai N, Horvath R, Wittwer C, editors. Tietz textbook of clinical chemistry and molecular diagnostics, 6th ed. St. Louis, Missouri, USA: Elsevier, 2018:81-120.
  17. Lippi G, Salvagno GL, Lima-Oliveira G, Danese E, Favaloro EJ, Guidi GC. Influence of posture on routine hemostasis testing. Blood Coagul Fibrinolysis 2015;26:716-9. DOI: 10.1097/MBC.0000000000000326
  18. Lippi G, Salvagno GL, Lima-Oliveira G, Brocco G, Danese E, Guidi GC. Postural change during venous blood collection is a major source of bias in clinical chemistry testing. Clin Chim Acta 2015;440:164-8. DOI: 10.1016/j.cca.2014.11.024
  19. Lippi G, Cervellin G. Acutely developing, spurious anemia without actual blood loss. A paradigmatic case report. Biochem Med 2017;27:421-5. DOI: 10.11613/BM.2017.045
  20. Lima-Oliveira G, Guidi GC, Salvagno GL, Danese E, Montagnana M, Lippi G. Patient posture for blood collection by venipuncture: recall for standardization after 28 years. Rev Bras Hematol Hemoter 2017;39:127-32. DOI: 10.1016/j.bjhh.2017.01.004
  21. van Dongen-Lases E, Cornes MP, Grankvist K, Ibarz M, Kristensen GB, Lippi G, et al. Patient identification and tube labelling - a call for harmonisation on behalf of the Working Group for Preanalytical Phase (WG-PRE), European Federation of Clinical Chemistry and Laboratory Medicine (EFLM). Clin Chem Lab Med 2016;54:1141-5. DOI: 10.1515/cclm-2015-1089
  22. Simundic AM, Cornes M, Grankvist K, Lippi G, Nybo M. Standardization of collection requirements for fasting samples. For the Working Group on Preanalytical Phase (WG-PA) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM). Clin Chim Acta 2014;432:33-7. DOI: 10.1016/j. cca.2013.11.008
  23. Lima-Oliveira G, Volanski W, Lippi G, Picheth G, Guidi GC. Preanalytical phase management: a review of the procedures from patient preparation to laboratory analysis. Scand J Clin Lab Invest 2017;77:153-63. DOI: 10.1080/00365513.2017.1295317
  24. Simundic AM, Dorotić A, Fumic K, Gudasic-Vrdoljak J, Kackov S, Klenkar K, et al. Patient preparation for laboratory testing: recommendation of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Biochem Med 2018. In press.
  25. Nikolac N, Supak-Smolcic V, Simundic AM, Celap I. Croatian Society of Medical Biochemistry and Laboratory Medicine: national recommendations for venous blood sampling. Biochem Med 2013;23:242-54. DOI: 10.11613/BM.2013.031
  26. Montagnana M, Danese E, Salvagno GL, Lippi G. Short-term effect of dark chocolate consumption on routine haemostasis testing. Int J Food Sci Nutr 2017;68:613-6. DOI: 10.1080/09637486.2016.1268101
  27. Lippi G, Lima-Oliveira G, Salvagno GL, Montagnana M, Gelati M, Picheth G, et al. Influence of a light meal on routine haematological tests. Blood Transfus 2010;8:94-9.
  28. Lima-Oliveira G, Salvagno GL, Lippi G, Gelati M, Montagnana M, Danese E, et al. Influence of a regular, standardized meal on clinical chemistry analytes. Ann Lab Med 2012;32:250-6. DOI: 10.3343/alm.2012.32.4.250
  29. Lima-Oliveira G, Salvagno GL, Lippi G, Danese E, Gelati M, Montagnana M, et al. Could light meal jeopardize laboratory coagulation tests? Biochem Med (Zagreb) 2014;24:343-9. DOI: 10.11613/BM.2014.036
  30. Simundic AM, Filipi P, Vrtaric A, Miler M, Nikolac Gabaj N, Kocsis A, et al. Patient’s knowledge and awareness about the effect of the over-the-counter (OTC) drugs and dietary supplements on laboratory test results: a survey in 18 European countries. Clin Chem Lab Med. 2018, in press. DOI: 10.1515/cclm-2018-0579
  31. Perovic A, Nikolac N, Braticevic NM, Milcic A, Sobocanec S, Balog T, et al. Does recreational scuba diving have clinically significant effect on routine haematological parameters? Biochem Med 2017;27:325-31. DOI: 10.11613/BM.2017.035
  32. Danese E, Salvagno GL, Tarperi C, Negrini D, Montagnana M, Festa L, et al. Middle-distance running acutely influences the concentration and composition of serum bile acids. Potential implications for cancer risk? Oncotarget 2017;8:52775-82. DOI: 10.18632/oncotarget.17188
  33. Corsetti R, Lombardi G, Barassi A, Lanteri P, Colombini A, D’Eril GM, et al. Cardiac indexes, cardiac damage biomarkers and energy expenditure in professional cyclists during the Giro d’Italia 3-weeks stage race. Biochem Med 2012;22:237-46. DOI: 10.11613/BM.2012.026
  34. Rasaiah B, Hoag G. Guidelines for a venous blood collection chair. Can Med Assoc J 1992;146:108-9.
  35. Lippi G, Cornes MP, Grankvist K, Nybo M, Simundic AM. European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE) opinion paper: local validation of blood collection tubes in clinical laboratories. Clin Chem Lab Med 2016;54:755-60. DOI: 10.1515/cclm-2015-1274
  36. Bostic G, Thompson R, Atanasoski S, Canlas C, Ye H, Kolins M, et al. Quality improvement in the coagulation laboratory: reducing the number of insufficient blood draw specimens for coagulation testing. Lab Med 2015;46:347-55. DOI: 10.1309/LMA4WYN3XFUKELBD
  37. Domingos MC, Medaille C, Concordet D, Briend-Marchal A. Is it possible to use expired tubes for routine biochemical analysis in dogs? Vet Clin Pathol 2012;41:266-71. DOI: 10.1111/j.1939-165X.2012.00424.x
  38. Verbeek JH, Ijaz S, Mischke C, Ruotsalainen JH, Makela E, Neuvonen K, et al. Personal protective equipment for preventing highly infectious diseases due to exposure to contaminated body fluids in healthcare staff. Cochrane Database Syst Rev 2016;4:CD011621. DOI: 10.1002/14651858.CD011621.pub2
  39. Kinlin LM, Mittleman MA, Harris AD, Rubin MA, Fisman DN. Use of gloves and reduction of risk of injury caused by needles or sharp medical devices in healthcare workers: results from a case-crossover study. Infect Control Hosp Epidemiol 2010;31:908-17. DOI: 10.1086/655839
  40. Mast ST, Woolwine JD, Gerberding JL. Efficacy of gloves in reducing blood volumes transferred during simulated needlestick injury. J Infect Dis 1993;168:1589-92. DOI: 10.1093/infdis/168.6.1589
  41. De Carli G, Abiteboul D, Puro V. The importance of implementing safe sharps practices in the laboratory setting in Europe. Biochem Med (Zagreb) 2014;24:45-56. DOI: 10.11613/BM.2014.007
  42. Bhargava A, Mishra B, Thakur A, Dogra V, Loomba P, Gupta S. Assessment of knowledge attitude and practices among healthcare workers in a tertiary care hospital on needle stick among injury. Int J Health Care Qual Assur 2013;26:549-58. DOI: 10.1108/IJHCQA-04-2012-0035
  43. Self WH, Mickanin J, Grijalva CG, Grant FH, Henderson MC, Corley G, et al. Reducing blood culture contamination in community hospital emergency departments: a multicenter evaluation of a quality improvement intervention. Acad Emerg Med 2014;21:274-82. DOI: 10.1111/acem.12337
  44. Self WH, Speroff T, Grijalva CG, McNaughton CD, Ashburn J, Liu D, et al. Reducing blood culture contamination in the emergency department: an interrupted time series quality improvement study. Acad Emerg Med 2013;20:89-97. DOI: 10.1111/acem.12057
  45. Mansouri M, Tidley M, Sanati KA, Roberts C. Comparison of blood transmission through latex and nitrile glove materials. Occup Med 2010;60:205-10. DOI: 10.1093/occmed/kqp196
  46. Wittman A, Kralj N, Kover J, Gasthaus K, Lerch H, Hofmann F. Comparison of 4 different types of surgical gloves used for preventing blood contact. Infect Control Hosp Epidemiol 2010;31:498-502. DOI: 10.1086/652158
  47. Pittet D, Allegranzi B, Sax H, Dharan S, Pessoa-Silva CL, Donaldson L, et al. Evidence-based model for hand transmission during patient care and the role of improved practices. Lancet Infect Dis 2006;6:641-52. DOI: 10.1016/S1473-3099(06)70600-4
  48. Dukic K, Zoric M, Pozaic P, Starcic J, Culjak M, Saracevic A, et al. How compliant are technicians with universal safety measures in medical laboratories in Croatia? - a pilot study. Biochem Med 2015;25:386-92. DOI: 10.11613/BM.2015.038
  49. Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Picheth G, Guidi GC. Impact of the venous blood collection training based on CLSI/NCCLS H03-A6 - procedures for the collection of diagnostic blood specimens by venipuncture. Biochem Med (Zagreb) 2012;22:342-51. DOI: 10.11613/BM.2012.036
  50. Culjak M, Gveric Grginic A, Simundic A-M. Bacterial contamination of reusable venipuncture tourniquets in tertiarycare hospital. Clin Chem Lab Med 2018;56:e201-3. DOI: 10.1515/cclm-2017-0994
  51. Mehmood Z, Muhammad Mubeen S, Shehzad Afzal M, Hussain Z. Potential risk of cross-infection by tourniquets: a need for effective control practices in Pakistan. Int J Prev Med 2014;5:1119-24.
  52. Pinto AN, Phan T, Sala G, Cheong EY, Siarakas S, Gottlieb T. Reusable venesection tourniquets: a potential source of hospital transmission of multiresistant organisms. Med J Aust 2011;195:276-9. DOI: 10.5694/mja11.10333
  53. Nikolac N, Lenicek Krleza J, Simundic AM. Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots. Biochem Med 2017;27:131-43. DOI: 10.11613/BM.2017.017
  54. Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Manguera CL, Sumita NM, et al. New ways to deal with known preanalytical issues: use of transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry. Biochem Med 2011;21:152-9. DOI: 10.11613/BM.2011.024
  55. Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Scartezini M, Guidi GC, et al. Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing. Int J Lab Hematol 2011;33:457-62. DOI: 10.1111/j.1751-553X.2011.01305.x
  56. Lima-Oliveira G, Salvagno GL, Lippi G, Montagnana M, Scartezini M, Picheth G, et al. Elimination of the venous stasis error for routine coagulation testing by transillumination. Clin Chim Acta 2011;412:1482-4. DOI: 10.1016/j.cca.2011.04.008
  57. Don BR, Sebastian A, Cheitlin M, Christiansen M, Schambelan M. Pseudohyperkalemia caused by fist clenching during venous blood collection. N Engl J Med 1990;322:1290-2. DOI: 10.1056/NEJM199005033221806
  58. Seimiya M, Yoshida T, Sawabe Y, Sogawa K, Umemura H, Matsushita K, et al. Reducing the incidence of pseudohyperkalemia by avoiding making a fist during venous blood collection: a quality improvement report. Am J Kidney Dis 2010;56:686-92. DOI: 10.1053/j.ajkd.2010.06.014
  59. Ialongo C, Bernardini S. Phlebotomy, a bridge between laboratory and patient. Biochem Med 2016;26:17-33. DOI: 10.11613/BM.2016.002
  60. Loh TP, Sethi SK. A multidisciplinary approach to reducing spurious hyperkalemia in hospital outpatient clinics. J Clin Nurs 2015;24:2900-6. DOI: 10.1111/jocn.12912
  61. Lima-Oliveira G, Guidi GC, Salvagno GL, Lippi G. The impact of fist clenching and its maintenance during venipuncture on routine hematology testing. J Clin Lab Anal 2017;31. doi: 10.1002/jcla.22108. DOI: 10.1002/jcla.22108
  62. Lima-Oliveira G, Guidi GC, Salvagno GL, Brocco G, Danese E, Lippi G. Estimation of the imprecision on clinical chemistry testing due to fist clenching and maintenance during venipuncture.Clin Biochem 2016;49:1364-7. DOI: 10.1016/j.clinbiochem.2016.07.007
  63. Putz R, Pabst R, editors. Sobotta: atlas of human anatomy, 20th ed. Munich, DE: Urban & Schwarzenberg/Elsevier, 1993.
  64. Horowitz SH. Venipuncture-induced causalgia: anatomic relations of upper extremity superficial veins and nerves, and clinical considerations. Transfusion 2000;40:1036-40. DOI: 10.1046/j.1537-2995.2000.40091036.x
  65. Ramos JA. Venipuncture-related lateral antebrachial cutaneous nerve injury: what to know? Braz J Anesthesiol 2014;64:131-3. DOI: 10.1016/j.bjane.2013.06.003
  66. Seifert H, Abele-Horn M, Fatkenheuer G, Shah PM. Mikrobiologische-infektiologische Qualitatsstandards (MiQ) - Blu tkulturdiagnostik,Urban&Fischer 2007, S.16-27 (in German).
  67. Anforderungen an die Hygiene bei Punktionen und Injektionen Empfehlung der Kommission fur Krankenhaushygiene und Infektions-pravention beim Robert Koch-Institut (RKI). Bundesgesundheitsbl 2011;54:1135-44. (in German). DOI: 10.1007/s00103-011-1352-8
  68. Patel TG, Shukla RV, Gupte SC. Impact of donor arm cleaning with different aseptic solutions for prevention of contamination in blood bags. Indian J Hematol Blood Transfus 2013;29:17-20. DOI: 10.1007/s12288-011-0138-3
  69. Ibanez-Cervantes G, Bello-Lopez JM, Fernandez-Sanchez V, Dominguez-Mendoza CA, Acevedo-Alfaro LI. Prevalence of bacterial contamination in platelet concentrates at the National Center of Blood Transfusion (Mexico). Transfus Clin Biol 2017;24:56-61. DOI: 10.1016/j.tracli.2017.03.003
  70. Pendlington RU, Whittle E, Robinson JA, Howes D. Fate of ethanol topically applied to skin. Food Chem Toxicol 2001;39:169-74. DOI: 10.1016/S0278-6915(00)00120-4
  71. Salvagno GL, Danese E, Lima-Oliveira G, Guidi GC, Lippi G. Avoidance to wipe alcohol before venipuncture is not a source of spurious hemolysis. Biochem Med 2013;23:201-5. DOI: 10.11613/BM.2013.023
  72. Lippi G, Simundic AM, Musile G, Danese E, Salvagno G, Tagliaro F. The alcohol used for cleansing the venipuncture site does not jeopardize blood and plasma alcohol measurement with head-space gas chromatography and an enzymatic assay. Biochem Med 2017;27:398-403. DOI: 10.11613/BM.2017.041
  73. Hadaway LC, Millam DA. On the road to successful I.V. starts. Nursing 2005;35(Suppl On):1-14; quiz 14-6. DOI: 10.1097/00152193-200505001-00001
  74. Cornes M, van Dongen-Lases E, Grankvist K, Ibarz M, Kristensen G, Lippi G, et al. Order of blood draw: opinion paper by the European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE). Clin Chem Lab Med 2017;55:27-31. DOI: 10.1515/cclm-2016-0426
  75. Smock KJ, Crist RA, Hansen SJ, Rodgers GM, Lehman CM. Discard tubes are not necessary when drawing samples for specialized coagulation testing. Blood Coagul Fibrinolysis 2010;21:279-82. DOI: 10.1097/MBC.0b013e3283380d12
  76. Lippi G, Guidi GC. Effect of specimen collection on routine coagulation assays and D-dimer measurement. Clin Chem 2004;50:2150-2. DOI: 10.1373/clinchem.2004.036244
  77. Sulaiman RA, Cornes MP, Whitehead S, Othonos N, Ford C, Gama R. Effect of order of draw of blood samples during venous blood collection on routine biochemistry results. J Clin Pathol 2011;64:1019-20. DOI: 10.1136/jclinpath-2011-200206
  78. Salvagno G, Lima-Oliveira G, Brocco G, Danese E, Guidi GC, Lippi G. The order of draw: myth or science? Clin Chem Lab Med 2013;51:2281-5. DOI: 10.1515/cclm-2013-0412
  79. Cornes MP, Ford C, Gama R. Spurious hyperkalaemia due to EDTA contamination: common and not always easy to identify. Ann Clin Biochem 2008;45:601-3. DOI: 10.1258/acb.2008.007241
  80. Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Picheth G, Guidi GC. Incorrect order of draw could be mitigate the patient safety: a phlebotomy management case report. Biochem Med (Zagreb) 2013;23:218-23. DOI: 10.11613/BM.2013.026
  81. Sharratt CL, Gilbert CJ, Cornes MP, Ford C, Gama R. EDTA sample contamination is common and often undetected, putting patients at unnecessary risk of harm. Int J Clin Pract 2009;63:1259-62. DOI: 10.1111/j.1742-1241.2008.01981.x
  82. Cadamuro J, Felder TK, Oberkofler H, Mrazek C, Wiedemann H, Haschke-Becher E. Relevance of EDTA carryover during blood collection. Clin Chem Lab Med 2015;53:1271-8. DOI: 10.1515/cclm-2014-0944
  83. Berg JE, Ahee P, Berg JD. Variation in venous blood collection techniques in emergency medicine and the incidence of haemolysed samples. Ann Clin Biochem 2011;48(Pt 6):562-5. DOI: 10.1258/acb.2011.011099
  84. Lippi G, Salvagno GL, Montagnana M, Brocco G, Guidi GC. Influence of short-term venous stasis on clinical chemistry testing. Clin Chem Lab Med 2005;43:869-75. DOI: 10.1515/CCLM.2005.146
  85. Lippi G, Salvagno GL, Montagnana M, Guidi GC. Short-term venous stasis influences routine coagulation testing. Blood Coagul Fibrinolysis 2005;16:453-8. DOI: 10.1097/01. mbc.0000178828.59866.03
  86. Lippi G, Salvagno GL, Montagnana M, Franchini M, Guidi GC. Venous stasis and routine hematologic testing. Clin Lab Haematol 2006;28:332-7. DOI: 10.1111/j.1365-2257.2006.00818.x
  87. Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Gelati M, Volanski W, et al. Effects of vigorous mixing of blood vacuum tubes on laboratory test results. Clin Biochem 2013;46:250-4. DOI: 10.1016/j.clinbiochem.2012.10.033
  88. Karlsson J, Helmersson-Karlqvist J, Larsson A. Delayed mixing of vacuum tubes clearly affects platelet counts but not haemoglobin concentration and prothrombin time (INR) results. Int J Lab Hematol 2013;35:15-7. DOI: 10.1111/ijlh.12096
  89. Clinical Laboratory Standards Institute. Collection, Transport, and Processing of Blood Specimens for Testing Plasma-Based Coagulation Assays and Molecular Hemostasis Assays. CLSI H21-A5 document. 5th ed. Wayne, PA: Clinical Laboratory Standards Institute, 2008.
  90. Lima-Oliveira G, Lippi G, Salvagno GL, Brocco G, Gaino S, Dima F, et al. Processing of diagnostic blood specimens: is it really necessary to mix primary blood tubes after collection with evacuated tube system? Biopreserv Biobank 2014;12:53-9. DOI: 10.1089/bio.2013.0043
  91. Parenmark A, Landberg E. To mix or not to mix venous blood samples collected in vacuum tubes? Clin Chem Lab Med 2011;49:2061-3. DOI: 10.1515/CCLM.2011.705
  92. Lippi G, Salvagno GL, Montagnana M, Banfi G, Guidi GC. Evaluation of different mixing procedures for K2 EDTA primary samples on hematological testing. Lab Med 2007;38:723-5. DOI: 10.1309/95R8A56BDN10AUUH
  93. Lippi G, Salvagno GL, Montagnana M, Guidi GC. Influence of primary sample mixing on routine coagulation testing. Blood Coagul Fibrinolysis 2007;18:709-11. DOI: 10.1097/MBC.0b013e32828621a0
  94. Lippi G, Plebani M. Primary blood tubes mixing: time for updated recommendations. Clin Chem Lab Med 2012;50:599-600. DOI: 10.1515/cclm-2012-0120
  95. Lima-Oliveira G, Lippi G, Salvagno GL, Picheth G, Guidi GC. Laboratory diagnostics and quality of blood collection. J Med Biochem 2015;34:288-94. DOI: 10.2478/jomb-2014-0043
  96. Directive 2010/32/EU - prevention from sharp injuries in the hospital and healthcare sector. https://osha.europa.eu/es/legislation/directives/council-directive-2010-32-eupreventionfrom-sharp-injuries-in-the-hospital-and-healthcare-sector. Accessed: 20 Jul 2017.
  97. Hansen HC, Harboe H, Drenck NE. Bruising after venepuncture. Ugeskr Laeger 1989;151:626-7.
  98. Blackmore M. Minimising bruising in the antecubital fossa after venipuncture. Br Med J (Clin Res Ed) 1987;295:332. DOI: 10.1136/bmj.295.6593.332-b
  99. Dyson A, Bogod D. Minimising bruising in the antecubital fossa after venipuncture. Br Med J (Clin Res Ed) 1987;294:1659. DOI: 10.1136/bmj.294.6588.1659
  100. Godwin PG, Cuthbert AC, Choyce A. Reducing bruising after venepuncture. Qual Health Care 1992;1:245-6. DOI: 10.1136/qshc.1.4.245
  101. Backman C, Zoutman DE, Marck PB. An integrative review of the current evidence on the relationship between hand hygiene interventions and the incidence of health care-associated infections. Am J Infect Control 2008;36:333-48. DOI: 10.1016/j. ajic.2007.08.007
  102. Vissers D, Matthyssen B, Truijen S, Blommaert S, Van De Velde K, Van Gaal L. Fainting and hemolysis during blood sampling in youngsters: prevalence study. Int J Nurs Stud 2008;45:760-4. DOI: 10.1016/j.ijnurstu.2006.12.014
  103. Martens RJ, Geijselaers SL, Stehouwer CD, Henry RM; Maastricht Study Group. Timing of syncope during blood sampling - the Maastricht Study. Eur J Intern Med 2017;43:e46-7. DOI: 10.1016/j.ejim.2017.05.024
  104. Graham DT. Prediction of fainting in blood donors. Circulation 1961;23:901-6. DOI: 10.1161/01.CIR.23.6.901
  105. France CR, France JL, Kowalsky JM, Ellis GD, Copley DM, Geneser A, et al. Assessment of donor fear enhances prediction of presyncopal symptoms among volunteer blood donors. Transfusion 2012;52:375-80. DOI: 10.1111/j.1537-2995.2011.03294.x
  106. Kotter JP. Leading change. Harvard Business Review Press, 1996.
  107. Makhumula-Nkhoma N, Whittaker V, McSherry R. Level of confidence in venepuncture and knowledge in determining causes of blood sample haemolysis among clinical staff and phlebotomists. J Clin Nurs 2015;24:370-85. DOI: 10.1111/jocn.12607
  108. Dorotić A, Antončić D, Biljak VR, Nedić D, Beletić A. Hemolysis from a nurses’ standpoint-survey from four Croatian hospitals. Biochem Med (Zagreb) 2015;25:393-400. DOI: 10.11613/BM.2015.039
  109. Milutinović D, Andrijević I, Ličina M, Andrijević L. Confidence level in venipuncture and knowledge on causes of in vitro hemolysis among healthcare professionals. Biochem Med (Zagreb) 2015;25:401-9. DOI: 10.11613/BM.2015.040
  110. Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Picheth G, Guidi GC. Impact of the phlebotomy training based on CLSI/NCCLS H03-A6- procedures for the collection of diagnostic blood specimens by venipuncture. Biochem Med 2012;22:342-51. DOI: 10.11613/BM.2012.036
  111. Bolenius K, Lindkvist M, Brulin C, Grankvist K, Nilsson K, Soderberg J. Impact of a large-scale educational intervention program on venous blood specimen collection practices. BMC Health Serv Res 2013;13:463. DOI: 10.1186/1472-6963-13-463
  112. Dukic L, Jokic A, Kules J, Pasalic D. The knowledge and understanding of preanalytical phase among biomedicine students at the University of Zagreb. Biochem Med 2016;26:90-7. DOI: 10.11613/BM.2016.009
  113. Simundic AM. Who is doing Phlebotomy in Europe? In: Guder WG, Narayanan S, editors. Pre-examination procedures in laboratory diagnostics. Preanalytical Aspects and their Impact on the Quality of Medical Laboratory Results. Berlin, Boston: De Gruyter, 2015. DOI: 10.1515/9783110334043-015
  114. Sciacovelli L, Panteghini M, Lippi G, Sumarac Z, Cadamuro J, Galoro CA, et al. Defining a roadmap for harmonizing quality indicators in Laboratory Medicine: a consensus statement on behalf of the IFCC Working Group “Laboratory Error and Patient Safety” and EFLM Task and Finish Group “Performance specifications for the extra-analytical phases”. Clin Chem Lab Med 2017;55:1478-88. DOI: 10.1515/cclm-2017-0412
  115. Plebani M, Sciacovelli L, Aita A, Chiozza ML. Harmonization of pre-analytical quality indicators. Biochem Med (Zagreb) 2014;24:105-13. DOI: 10.11613/BM.2014.012
  116. Plebani M, Sciacovelli L, Aita A, Pelloso M, Chiozza ML. Performance criteria and quality indicators for the pre-analytical phase. Clin Chem Lab Med 2015;53:943-8. DOI: 10.1515/cclm-2014-1124
  117. Plebani M; EFLM Task Force on Performance Specifications for the extra-analytical phases. Performance specifications for the extra-analytical phases of laboratory testing: why and how. Clin Biochem 2017;50:550-4. DOI: 10.1016/j. clinbiochem.2017.02.002
  118. Karcher DS, Lehman CM. Clinical consequences of specimen rejection: a College of American Pathologists Q-Probes analysis of 78 clinical laboratories. Arch Pathol Lab Med 2014;138:1003-8. DOI: 10.5858/arpa.2013-0331-CP
  119. Lippi G, Bonelli P, Cervellin G. Prevalence and cost of hemolyzed samples in a large urban emergency department. Int J Lab Hematol 2014;36:e24-6. DOI: 10.1111/ijlh.12135
  120. Ong ME, Chan YH, Lim CS. Reducing blood sample hemolysis at a tertiary hospital emergency department. Am J Med 2009;122:1054.e1-6. DOI: 10.1016/j.amjmed.2009.04.024
  121. Simundic AM, Cadamuro J, Cornes J. Biochemia Medica introduces new section: pre-analytical mysteries. Biochem Med 2017;27:418-20. DOI: 10.11613/BM.2017.044
  122. Cornes M. Case report of unexpected hypocalcaemia in a slightly haemolysed sample. Biochem Med (Zagreb) 2017;27:426-9. DOI: 10.11613/BM.2017.046
  123. Cadamuro J, Wiedemann H, Felder TK, Mrazek C, Kipman U, Hannes O, et al. What/s floating on my plasma? Biochem Med (Zagreb) 2017;27:430-3. DOI: 10.11613/BM.2017.047
  124. Lippi G, Simundic A-M; European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE). The EFLM strategy for harmonization of the preanalytical phase. Clin Chem Lab Med 2018;56:1660-6 DOI: 10.1515/cclm-2017-0277
  125. Cornes MP, Church S, van Dongen-Lases E, Grankvist K, Guimaraes JT, Ibarz M, et al. The role of European Federation of Clinical Chemistry and Laboratory Medicine Working Group for Preanalytical Phase in standardization and harmonization of the preanalytical phase in Europe. Ann Clin Biochem 2016;53(Pt 5):539-47 DOI: 10.1177/0004563216643969
DOI: https://doi.org/10.2478/rrlm-2024-0004 | Journal eISSN: 2284-5623 | Journal ISSN: 1841-6624
Language: English
Page range: 9 - 32
Submitted on: Jun 9, 2018
|
Accepted on: Jun 10, 2018
|
Published on: Jan 29, 2024
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2024 Ana-Maria Simundic, Karin Bolenius, Janne Cadamuro, Stephen Church, Michael P. Cornes, Edmee C. van Dongen-Lases, Pinar Eker, Tanja Erdeljanovic, Kjell Grankvist, Joao Tiago Guimaraes, Roger Hoke, Mercedes Ibarz, Helene Ivanov, Svetlana Kovalevskaya, Gunn B.B. Kristensen, Gabriel Lima-Oliveira, Giuseppe Lippi, Alexander von Meyer, Mads Nybo, Barbara De la Salle, Christa Seipelt, Zorica Sumarac, Pieter Vermeersch, , published by Romanian Association of Laboratory Medicine
This work is licensed under the Creative Commons Attribution 4.0 License.