Have a personal or library account? Click to login
Pseudohyponatremia and falsely increased serum osmolal gap caused by paraprotein in a patient with severe metabolic acidosis – a case study Cover

Pseudohyponatremia and falsely increased serum osmolal gap caused by paraprotein in a patient with severe metabolic acidosis – a case study

By: Tomáš Šálek  
Open Access
|Apr 2021

Abstract

Introduction: The aim of the study is to present a case study of a 63-year-old male with pseudohyponatremia, falsely increased serum osmolal gap and severe metabolic acidosis.

Material and Methods: Venous whole blood (direct sodium selective electrode measurement) and serum (indirect sodium selective electrode measurement) were used to measure sodium concentration. Serum cholesterol, triacylglycerides and total protein were measured to confirm pseudohyponatremia. Base excess in extracellular fluid and serum bicarbonate concentrations were employed as markers of metabolic acidosis. Serum protein electrophoresis and free light chain analysis were used for the detection of paraproteins.

Results: Venous whole blood acid base analysis showed a pH of 7.171, negative base excess in extracellular fluid of – 18.6 mmol/L and sodium concentration of 140 mmol/L. Serum test measurement revealed serum sodium concentration of 130 mmol/L, osmolal gap of 24 mmol/kg, creatinine concentration of 702 µmol/L, HCO3- concentration of 6.1 mmol/L and total protein concentration of 134.9 g/L. Serum paraprotein IgG kappa with a concentration of 86 g/L and a serum free light chains kappa/lambda ratio of 223.5, along with the final diagnosis of multiple myeloma were detected. Toxic alcohol ingestion was considered, both methanol and ethylene glycol tests were negative.

Conclusions: High paraprotein concentrations in serum may lead to pseudohyponatremia when measured by indirect ion selective electrodes. Multiple myeloma frequently leads to renal failure with metabolic acidosis.

DOI: https://doi.org/10.2478/rrlm-2021-0017 | Journal eISSN: 2284-5623 | Journal ISSN: 1841-6624
Language: English
Page range: 229 - 233
Submitted on: Mar 15, 2021
|
Accepted on: Apr 6, 2021
|
Published on: Apr 27, 2021
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2021 Tomáš Šálek, published by Romanian Association of Laboratory Medicine
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.