Have a personal or library account? Click to login

Comparison of Total Bilirubin Values Measured with ABL 735 Blood Gas Analyzer and Roche Cobas C8000 Chemistry Analyzer in Age-Segregated Pediatric Patients

Open Access
|May 2019

References

  1. 1. Porter ML, Dennis BL. Hyperbilirubinemia in the term newborn. Am Fam Physician. 2002 Feb 15;65(4):599-606.
  2. 2. Amin SB, Lamola AA, editors. Newborn jaundice technologies: unbound bilirubin and bilirubin binding capacity in neonates. Seminars in perinatology. Semin Perinatol. 2011 Jun;35(3):134-40. DOI: 10.1053/j.sem-peri.2011.02.00710.1053/j.sem-peri.2011.02.007
  3. 3. Callen J, Traber Davis Giardina HS, Li L, Paoloni R, Georgiou A, Runciman WB, et al. Emergency physi-cians’ views of direct notification of laboratory and radiology results to patients using the internet: a multisite survey. JJ Med Internet Res. 2015 Mar 4;17(3):e60. DOI: 10.2196/jmir.372110.2196/jmir.3721437615425739322
  4. 4. Blick KE. Providing critical laboratory results on time, every time to help reduce emergency department length of stay: how our laboratory achieved a Six Sigma level of performance. Am J Clin Pathol. 2013 Aug;140(2):193-202. DOI: 10.1309/AJCPNUTIPQTRRG0D10.1309/AJCPNUTIPQTRRG0
  5. 5. Nichols JH. Point of care testing. Clin Lab Med. 2007 Dec;27(4):893-908, viii. DOI: 10.1016/j.cll.2007.07.00310.1016/j.cll.2007.07.00317950904
  6. 6. Sacks DB, Arnold M, Bakris GL, Bruns DE, Horvath AR, Kirkman MS, et al. Executive summary: guide-lines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem. 2011 Jun;57(6):793-8. DOI: 10.1373/clinchem.2011.16363410.1373/clinchem.2011.16363421617153
  7. 7. Allardet-Servent J, Lebsir M, Dubroca C, Fabrigoule M, Jordana S, Signouret T, et al. Point-of-care versus central laboratory measurements of hemoglobin, he-matocrit, glucose, bicarbonate and electrolytes: a pro-spective observational study in critically ill patients. PloS one. 2017;12(1):e0169593. DOI: 10.1371/journal.pone.016959310.1371/journal.pone.0169593522482528072822
  8. 8. Mielsch C, Zimmermann A, Wagner D, Matthes B, Schlebusch H, Luppa PB. Point-of-care determination of neonatal bilirubin with the blood gas analyzer Rapid-Lab 1265. Clin Chem Lab Med. 2010 Oct;48(10):1455-61. DOI: 10.1515/CCLM.2010.27910.1515/CCLM.2010.27920604721
  9. 9. Fujiwara R, Haag M, Schaeffeler E, Nies AT, Zanger UM, Schwab M. Systemic regulation of bilirubin ho-meostasis: potential benefits of hyperbilirubinemia. Hepatology. 2018;67(4):1609-19. DOI: 10.1002/hep.2959910.1002/hep.2959929059457
  10. 10. Gazzin S, Vitek L, Watchko J, Shapiro SM, Tiribelli C. A novel perspective on the biology of bilirubin in health and disease. Trends Mol Med. 2016 Sep;22(9):758-68. DOI: 10.1016/j.molmed.2016.07.00410.1016/j.molmed.2016.07.00427515064
  11. 11. Chee Y, Chung PH, Wong RM, Wong KK. Jaundice in infants and children: causes, diagnosis, and management. Hong Kong Med J. 2018;24(3):285-92. DOI: 10.12809/hkmj18724510.12809/hkmj18724529807950
  12. 12. Ng MCW, How CH. When babies turn yellow. Singapore Med J. 2015;56(11):599. DOI: 10.11622/smedj.201516710.11622/smedj.2015167
  13. 13. Lano IM, Lyon AW, Wang L, Ruskin R, Lyon ME. Comparative evaluation of neonatal bilirubin using Radiometer whole blood co-oximetry and plasma bilirubin methods from Roche Diagnostics and Ortho Clinical Diagnostics. Clin biochem. 2018;53:88-92. DOI: 10.1016/j.clinbiochem.2017.12.00910.1016/j.clinbiochem.2017.12.009
  14. 14. Doumas BT, Poon Pat K-C, Perry BW. Candidate reference method for determination of TB in serum: Development and validation. Clin Chem. 1985;31(11):1779-89.10.1093/clinchem/31.11.1779
  15. 15. Tiker F, Gurakan B, Tarcan A. Serum bilirubin levels in 1-month-old, healthy, term infants from southern Turkey. Ann Trop Paediatr. 2002 Sep;22(3):225-8. DOI: 10.1179/02724930212500160610.1179/027249302125001606
  16. 16. Burnett R, Covington A, Fogh-Andersen N, Külpmann W, Maas A, Müller-Plathe O, et al., editors. International Federation of Clin Chem (IFCC). Scientific Division. Committee on pH, Blood Gases and Electrolytes. Approved IFCC recommendations on whole blood sampling, transport and storage for simultaneous determination of pH, blood gases and electrolytes. European journal of Clin Chem and clinical biochemistry: journal of the Forum of European Clin Chem Societies; 1995.
  17. 17. Lum G, Gambino SR. A comparison of serum versus heparinized plasma for routine chemistry tests. Am J Clin Pathol. 1974 Jan;61(1):108-13. DOI: 10.1093/ajcp/61.1.10810.1093/ajcp/61.1.108
  18. 18. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307-10. DOI: 10.1016/S0140-6736(86)90837-810.1016/S0140-6736(86)90837-8
  19. 19. Cornbleet PJ, Gochman N. Incorrect least-squares regression coefficients in method-comparison analysis. Clin Chem. 1979;25(3):432-8.10.1093/clinchem/25.3.432
  20. 20. Grohmann K, Roser M, Rolinski B, Kadow I, Müller C, Goerlach-Graw A, et al. Bilirubin measurement for ne-onates: comparison of 9 frequently used methods. Pediatrics. 2006;117(4):1174-83. DOI: 10.1542/peds.2005-059010.1542/peds.2005-059016585313
  21. 21. Rosenthal P. Errors in neonatal bilirubin measurement. Clin Chem. 1996;42(11):1880-1.10.1093/clinchem/42.11.1880a
  22. 22. Mussavi M, Niknafs P, Bijari B. Determining the correlation and accuracy of three methods of measuring neonatal bilirubin concentration. Iran J Pediatr. 2013 Jun; 23(3):333–39.
  23. 23. Uyanik M, Sertoglu E, Kayadibi H, Tapan S, Serdar MA, Bilgi C, et al. Comparison of blood gas, electrolyte and metabolite results measured with two different blood gas analyzers and a core laboratory analyzer. Scand J Clin Lab Invest. 2015 Apr;75(2):97-105. DOI: 10.3109/00365513.2014.98185410.3109/00365513.2014.98185425431133
  24. 24. Hawkins RC. Laboratory turnaround time. Clin Biochem Rev. 2007 Nov;28(4):179-94.
  25. 25. Dimeski G, Barnett R. Effects of total plasma protein concentration on plasma sodium, potassium and chloride measurements by an indirect ion selective electrode measuring system. Crit Care Resuscitation. 2005;7(1):12.10.1016/S1441-2772(23)01564-8
  26. 26. Chow E, Fox N, Gama R. Effect of low serum total protein on sodium and potassium measurement by ion-selective electrodes in critically ill patients. British J Biomed Sci. 2008;65(3):128-31. DOI: 10.1080/09674845.2008.1173281510.1080/09674845.2008.1173281518986099
  27. 27. Peake M, Mazzachi B, Fudge A, Bais R. Bilirubin measured on a blood gas analyser: a suitable alternative for near-patient assessment of neonatal jaun-dice? Ann Clin Biochem. 2001;38(5):533-40. DOI: 10.1177/00045632010380051110.1177/00045632010380051111587132
  28. 28. Rolinski B, Küster H, Ugele B, Gruber R, Horn K. TB measurement by photometry on a blood gas analyzer: potential for use in neonatal testing at the point of care. Clin Chem. 2001;47(10):1845-7.10.1093/clinchem/47.10.1845
  29. 29. Nuran Ö, Ataman K, Armağan E, SERT ÇP, BALCI AK, Taylan İ. Acil serviste kan gazı değerlerinin biyokimyasal değerler yerine kullanılabilirliği. Gaziantep Med J. 2012;18(3):155-9.10.5455/GMJ-30-2012-105
  30. 30. Bozkurt S, Altunören O, Kurutaş E, Doğan M. Venöz kan gazı potasyum sonuçları ile laboratuar potasyum sonuçlarının karşılaştırılması. JAEM. 2012;11(2):73-6. DOI: 10.5152/jaem.2012.0210.5152/jaem.2012.02
  31. 31. Story DA, Poustie S. Agreement between two plasma bicarbonate assays in critically ill patients. Anaesth Intensive Care. 2000 Aug;28(4):399-402.10.1177/0310057X000280040710969366
  32. 32. Kelly AM, McAlpine R, Kyle E. Agreement between bicarbonate measured on arterial and venous blood gases. Emerg Med Australas. 2004 Oct-Dec;16(5-6):407-9.10.1111/j.1742-6723.2004.00642.x15537402
  33. 33. Wongyingsinn M, Suksuriyayothin S. Use of rapid ABG analyzer in measurement of potassium concentration: does it agree with venous potassium concentration? J Med Assoc Thai. 2009 Jul;92(7):925-9.
  34. 34. Nambara T, Katayama Y, Enomoto M, Kikuchi S, Takei A, Ikegami H, et al. Reliability of TB Measurements in Whole Blood from Preterm Neonates Using a Blood Gas Analyzer. Clin Lab. 2016;62(11):2285-9.10.7754/Clin.Lab.2016.160419
DOI: https://doi.org/10.2478/rrlm-2019-0006 | Journal eISSN: 2284-5623 | Journal ISSN: 1841-6624
Language: English
Page range: 137 - 145
Submitted on: Aug 9, 2018
Accepted on: Dec 25, 2018
Published on: May 2, 2019
Published by: Romanian Association of Laboratory Medicine
In partnership with: Paradigm Publishing Services
Publication frequency: 4 times per year

© 2019 Esra Acar, Fatih Hunc, Tugba Kum, Fatma Ceyla Eraldemir, Hale Maral Kır, Canan Baydemir, published by Romanian Association of Laboratory Medicine
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.