Abstract

A standardized device with a volume of 1 m3 or 20 L is used to determine explosion parameters. An explosion chamber where explosion takes place is of a spherical or cylindrical shape that suits the shape of a cubic container. In the case of a cylindrical vessel, the diameter and depth of the vessel are 1: 1. In this case, it is a spherical vessel with a volume of 365 liters. Time parameters of the disperser in the spherical vessel are compared with those of a truncated spherical vessel with a volume of 291 liters. Comparison of the measurement results showed that the optimal delay time of the explosion chamber with a volume of 291 liters is 290 ms, while the delay time of the explosion chamber with a volume of 365 liters is 350 ms.

Language: English
Page range: 143 - 148
Submitted on: Apr 28, 2021
Accepted on: May 21, 2021
Published on: Aug 5, 2021
Published by: Slovak University of Technology in Bratislava
In partnership with: Paradigm Publishing Services
Publication frequency: 2 times per year

© 2021 Zuzana Szabová, Richard Kuracina, Miroslav Mynarz, Marián Škvarka, published by Slovak University of Technology in Bratislava