Have a personal or library account? Click to login
Determination of Emissivity of Brass Alloy using Infrared Thermographic Technique Cover

Determination of Emissivity of Brass Alloy using Infrared Thermographic Technique

Open Access
|Dec 2018

Abstract

This paper presents the experimental determination of the dependence of emissivity of brass on surface roughness and temperature. The investigation was conducted using the infrared thermographic technique on brass alloy C27200 workpieces with different degrees of surface roughness, during the continuous cooling process. The results obtained showed that the emissivity of the chosen brass alloy increases with greater surface roughness and decreases during the cooling process, its value ranging from 0.07 to 0.19. It was concluded that surface roughness has a greater influence on the increase of the emissivity at higher temperatures, which can be seen in the three-dimensional infrared images. Multiple regression analysis confirmed a strong correlation between the examined parameters and the emissivity, and an original multiple regression model was determined.

Language: English
Page range: 115 - 121
Submitted on: May 1, 2018
|
Accepted on: Jun 8, 2018
|
Published on: Dec 6, 2018
Published by: Sciendo
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2018 Zorana Lanc, Milan Zeljković, Aleksandar Živković, Branko Štrbac, Miodrag Hadžistević, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.