Have a personal or library account? Click to login

Breast size and dose to cardiac substructures in adjuvant three-dimensional conformal radiotherapy compared to tangential intensity modulated radiotherapy

Open Access
|Sep 2020

Abstract

Background

The aim of the study was to quantify planned doses to the heart and specific cardiac substructures in free-breathing adjuvant three-dimensional radiation therapy (3D-CRT) and tangential intensity modulated radiotherapy (t-IMRT) for left-sided node-negative breast cancer, and to assess the differences in planned doses to organs at risk according to patients’ individual anatomy, including breast volume.

Patients and methods

In the study, the whole heart and cardiac substructures were delineated for 60 patients using cardiac atlas. For each patient, 3D-CRT and t-IMRT plans were generated. The prescribed dose was 42.72 Gy in 16 fractions. Patients were divided into groups with small, medium, and large clinical target volume (CTV). Calculated dose distributions were compared amongst the two techniques and the three different groups of CTV.

Results

Mean absorbed dose to the whole heart (MWHD) (1.9 vs. 2.1 Gy, P < 0.005), left anterior descending coronary artery mean dose (8.2 vs. 8.4 Gy, P < 0.005) and left ventricle (LV) mean dose (3.0 vs. 3.2, P < 0.005) were all significantly lower with 3D-CRT technique compared to t-IMRT. Apical (8.5 vs. 9.0, P < 0.005) and anterior LV walls (5.0 vs. 5.4 Gy, P < 0.005) received the highest mean dose (Dmean). MWHD and LV-Dmean increased with increasing CTV size regardless of the technique. Low MWHD values (< 2.5 Gy) were achieved in 44 (73.3%) and 41 (68.3%) patients for 3D-CRT and t-IMRT techniques, correspondingly.

Conclusions

Our study confirms a considerable range of the planned doses within the heart for adjuvant 3D-CRT or t-IMRT in node-negative breast cancer. We observed differences in heart dosimetric metrics between the three groups of CTV size, regardless of the radiotherapy planning technique.

DOI: https://doi.org/10.2478/raon-2020-0050 | Journal eISSN: 1581-3207 | Journal ISSN: 1318-2099
Language: English
Page range: 470 - 479
Submitted on: Mar 18, 2020
Accepted on: May 10, 2020
Published on: Sep 29, 2020
Published by: Association of Radiology and Oncology
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2020 Ivica Ratosa, Aljasa Jenko, Zeljko Sljivic, Maja Pirnat, Irena Oblak, published by Association of Radiology and Oncology
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.