Have a personal or library account? Click to login
Comparison of Fluoroscopically and Arthroscopically Assisted Volar Plating of Articular Distal Radius Fractures Cover

Comparison of Fluoroscopically and Arthroscopically Assisted Volar Plating of Articular Distal Radius Fractures

Open Access
|Mar 2021

References

  1. Abe, Y. (2014). Plate presetting and arthroscopic reduction technique (part) for treatment of distal radius fractures. Handchir. Mikrochir. Plast. Chir., 46, 278–285.10.1055/s-0034-138770525290270
  2. Abe, Y., Fujii, K. (2017). Arthroscopic-assisted reduction of intra-articular distal radius fracture. Hand Clin.,33, 659–668.10.1016/j.hcl.2017.07.01128991578
  3. Auge, W. K., 2nd, Velazquez, P. A. (2000). The application of indirect reduction techniques in the distal radius: The role of adjuvant arthroscopy. Arthroscopy, 16, 830–835.10.1053/jars.2000.1771711078539
  4. Burnier, M., Le Chatelier Riquier, M., Herzberg, G. (2018). Treatment of intra-articular fracture of distal radius fractures with fluoroscopic only or combined with arthroscopic control: A prospective tomodensitometric comparative study of 40 patients. Orthop. Traumatol. Surg. Res., 104, 89–93.10.1016/j.otsr.2017.08.02129241818
  5. Del Pinal, F. (2011). Technical tips for (dry) arthroscopic reduction and internal fixation of distal radius fractures. J. Hand Surg. Amer., 36, 1694–1705.10.1016/j.jhsa.2011.07.02121971058
  6. Doi, K., Hattori, Y., Otsuka, K., Abe, Y., Yamamoto, H. (1999). Intra-articular fractures of the distal aspect of the radius: Arthroscopically assisted reduction compared with open reduction and internal fixation. J. Bone Joint Surg. Amer., 81, 1093–1110.10.2106/00004623-199908000-0000510466642
  7. Esposito, J., Schemitsch, E. H., Saccone, M., Sternheim, A., Kuzyk, P. R. (2013). External fixation versus open reduction with plate fixation for distal radius fractures: A meta-analysis of randomised controlled trials. Injury, 44, 409–416.10.1016/j.injury.2012.12.00323298757
  8. Franceschi, F., Franceschetti, E., Paciotti, M., Cancilleri, F., Maffulli, N., Denaro, V. (2015). Volar locking plates versus k-wire/pin fixation for the treatment of distal radial fractures: A systematic review and quantitative synthesis. Brit. Med. Bull., 115, 91–110.10.1093/bmb/ldv01525918348
  9. Freeland, A. E., Geissler, W. B. (2000). The arthroscopic management of intra-articular distal radius fractures. Hand Surg., 5, 93–102.10.1142/S021881040000020X
  10. Joseph, S. J., Harvey, J. N. (2011). The dorsal horizon view: Detecting screw protrusion at the distal radius. J. Hand Surg. Amer., 36, 1691–1693.10.1016/j.jhsa.2011.07.02021864994
  11. Jupiter, J. B., Marent-Huber, M., Group LCPS. (2009). Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series. J. Bone Joint Surg. Amer., 91, 55–65.10.2106/JBJS.G.0149819122079
  12. Khanchandani, P., Badia, A. (2013). Functional outcome of arthroscopic assisted fixation of distal radius fractures. Indian J. Orthop., 47, 288–294.10.4103/0019-5413.109872368790723798761
  13. Koo, O. T., Tan, D. M., Chong, A. K. (2013). Distal radius fractures: An epidemiological review. Orthop. Surg., 5, 209–213.10.1111/os.12045658328524002839
  14. Krustins, U., Krustins, J., Bringina, D., Laurane, K., Jumtins, A. (2020). Comparison of volar locking plates with external fixation and k-wires in arthroscopically assisted intra-articular distal radial fracture fixation. J. Hand Surg. Eur., 45 (4), 333–338.10.1177/175319341987956731594424
  15. Lutsky, K., Boyer, M. I., Steffen, J. A., Goldfarb, C. A. (2008). Arthroscopic assessment of intra-articular distal radius fractures after open reduction and internal fixation from a volar approach. J. Hand Surg. Amer., 33, 476–484.10.1016/j.jhsa.2007.12.00918406950
  16. Matschke, S., Marent-Huber, M., Audige, L., Wentzensen, A., Group LCPS. (2011). The surgical treatment of unstable distal radius fractures by angle stable implants: A multicenter prospective study. J. Orthop. Trauma, 25, 312–317.10.1097/BOT.0b013e3181f2b09e21464738
  17. Mehrzad, R., Kim, D. C. (2016). Complication rate comparing variable angle distal locking plate to fixed angle plate fixation of distal radius fractures. Ann. Plast. Surg., 77, 623–625.10.1097/SAP.000000000000085027404475
  18. Ono, H., Furuta, K., Fujitani, R., Katayama, T., Akahane, M. (2010). Distal radius fracture arthroscopic intraarticular displacement measurement after open reduction and internal fixation from a volar approach. J. Orthop. Sci., 15, 502–508.10.1007/s00776-010-1484-y20721718
  19. Ono, H., Katayama, T., Furuta, K., Suzuki, D., Fujitani, R., Akahane, M. (2012). Distal radial fracture arthroscopic intraarticular gap and step-off measurement after open reduction and internal fixation with a volar locked plate. J. Orthop. Sci., 17, 443–449.10.1007/s00776-012-0226-822526714
  20. Richard, M. J., Wartinbee, D. A., Riboh, J., Miller, M., Leversedge, F. J., Ruch, D. S. (2011). Analysis of the complications of palmar plating versus external fixation for fractures of the distal radius. J. Hand Surg. Amer., 36, 1614–1620.10.1016/j.jhsa.2011.06.03021849236
  21. Ruch, D. S., Vallee, J., Poehling, G. G., Smith, B. P., Kuzma, G. R. (2004). Arthroscopic reduction versus fluoroscopic reduction in the management of intra-articular distal radius fractures. Arthroscopy, 20, 225–230.10.1016/j.arthro.2004.01.01015007310
  22. Sander, A. L., Leiblein, M., Sommer, K., Marzi, I., Schneidmuller, D., Frank, J. (2018). Epidemiology and treatment of distal radius fractures: Current concept based on fracture severity and not on age. Eur. J. Trauma Emerg. Surg., 46 (3), 585–590.10.1007/s00068-018-1023-7
  23. Selles, C. A., Mulders, M. A. M., Colaris, J. W., van Heijl, M., Cleffken, B. I., Schep, N. W. L. (2020). Arthroscopic debridement does not enhance surgical treatment of intra-articular distal radius fractures: A randomized controlled trial. J. Hand Surg. Eur., 45 (4), 327–332.10.1177/175319341986612831686586
  24. Shukla, R., Jain, R. K., Sharma, N. K., Kumar, R. (2014). External fixation versus volar locking plate for displaced intra-articular distal radius fractures: A prospective randomized comparative study of the functional outcomes. J. Orthop. Traumatol., 15, 265–270.10.1007/s10195-014-0317-8424455525193416
  25. Souer, J. S., Ring, D., Matschke, S., Audige, L., Maren-Hubert, M., Jupiter, J. (2010). Comparison of functional outcome after volar plate fixation with 2.4-mm titanium versus 3.5-mm stainless-steel plate for extra-articular fracture of distal radius. J. Hand Surg. Amer., 35, 398–405.10.1016/j.jhsa.2009.11.02320138716
  26. Varitimidis, S. E., Basdekis, G. K., Dailiana, Z. H., Hantes, M. E., Bargiotas, K., Malizos, K. (2008). Treatment of intra-articular fractures of the distal radius: Fluoroscopic or arthroscopic reduction? J. Bone Joint Surg. Brit., 90, 778–785.10.1302/0301-620X.90B6.1980918539672
  27. Von Recum, J., Matschke, S., Jupiter, J. B., Ring, D., Souer, J. S., Huber, M., Audigé, L. (2012). Characteristics of two different locking compression plates in the volar fixation of complex articular distal radius fractures. Bone Joint Res., 1, 111–117.10.1302/2046-3758.16.2000008362619523610680
  28. Wilcke, M. K., Abbaszadegan, H., Adolphson, P. Y. (2011). Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year. Acta Orthop., 82, 76–81.10.3109/17453674.2011.552781323000121281262
  29. Williksen, J. H., Frihagen, F., Hellund, J. C., Kvernmo, H. D., Husby, T. (2013). Volar locking plates versus external fixation and adjuvant pin fixation in unstable distal radius fractures: A randomized, controlled study. J. Hand Surg. Amer., 38, 1469–1476.10.1016/j.jhsa.2013.04.03923890493
  30. Wright, T. W., Horodyski, M., Smith, D. W. (2005). Functional outcome of unstable distal radius fractures: Orif with a volar fixed-angle tine plate versus external fixation. J. Hand Surg. Amer., 30, 289–299.10.1016/j.jhsa.2004.11.01415781351
  31. Xie, X., Xie, X., Qin, H., Shen, L., Zhang, C. (2013). Comparison of internal and external fixation of distal radius fractures. Acta Orthop., 84, 286–291.10.3109/17453674.2013.792029371581923594247
  32. Yamazaki, H., Uchiyama, S., Komatsu, M., Hashimoto, S., Kobayashi, Y., Sakurai, T., Kato, H. (2015). Arthroscopic assistance does not improve the functional or radiographic outcome of unstable intra-articular distal radial fractures treated with a volar locking plate: A randomised controlled trial. Bone Joint J., 97-B, 957–962.10.1302/0301-620X.97B7.3535426130352
DOI: https://doi.org/10.2478/prolas-2021-0010 | Journal eISSN: 2255-890X | Journal ISSN: 1407-009X
Language: English
Page range: 58 - 64
Submitted on: Jul 28, 2020
|
Accepted on: Feb 4, 2021
|
Published on: Mar 1, 2021
In partnership with: Paradigm Publishing Services
Publication frequency: 6 issues per year

© 2021 Uldis Krustiņš, Vadims Nefjodovs, Diāna Bringina, Aija Jaudzema, Andris Jumtiņš, published by Latvian Academy of Sciences
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.