Have a personal or library account? Click to login

References

  1. IAEA, 2002. Calibration of Photon and Beta Ray Sources Used in Brachytherapy. Number 1274 in TECDOC Series. International Atomic Energy Agency; 2002.
  2. Nath R, Anderson LL, Luxton G, Weaver KA, Williamson JF, Meigooni AS. Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys. 1995;22(2):209-234. https://doi.org/10.1118/1.597458
  3. Williamson JF. Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds. Medical Physics. 1991;18(4):776-786. https://doi.org/10.1118/1.596631
  4. DeWerd LA, Ibbott GS, Meigooni AS, et al. A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC-ESTRO. Medical Physics. 2011;38(2):782-801. https://doi.org/10.1118/1.3533720
  5. Daskalov GM, Löffler E, Williamson JF. Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source. Medical Physics. 1998;25(11):2200-2208. https://doi.org/10.1118/1.598418
  6. Boutillon M, Perroche AM. Ionometric determination of absorbed dose to water for cobalt-60 gamma rays. Phys Med Biol. 1993;38(3):439-454. https://doi.org/10.1088/0031-9155/38/3/010
  7. ICRU Report 90, Key Data For Ionizing-Radiation Dosimetry: Measurement Standards And Applications – ICRU. Accessed April 17, 2024. https://www.icru.org/report/icru-report-90-key-data-for-ionizing-radiation-dosimetry-measurement-standards-and-applications.
  8. Szymko M. Budowa wzorca dawki pochłoniętej w wodzie dla źródeł stosowanych w brachyterapii [Construction of the water absorbed dose standard for sources used in brachytherapy]. [PhD thesis]. Warsaw University of Technology; 2024. https://repo.pw.edu.pl/info/phd/WUT8634915e3b994ce4a077bf2aedf3373e/
  9. IAEA. Absorbed Dose Determination in External Beam Radiotherapy. Technical Reports Series. Published online 2024. https://doi.org/10.61092/iaea.ve7q-y94k
  10. Szymko MM, Knyziak AB, Derlaciński M. Graphite ionization chamber as an ionometric standard of absorbed dose to water for Co-60 gamma radiation. Measurement. 2022;194:110928. https://doi.org/10.1016/j.measurement.2022.110928
  11. Andreo P, Burns DT, Nahum AE, Seuntjens J, Attix,FH. Fundamentals of ionizing radiation dosimetry. John Wiley & Sons; 2017.
  12. Szymko MM, Michalik L, Knyziak AB, Wójtowicz AW. Development and characterization of air kerma cavity standard. Measurement. 2019;136:647-657. https://doi.org/10.1016/j.measurement.2019.01.010
  13. Bravos manual. https://www.varian.com/resources-support/support/product-documentation
  14. Rozporządzenie Ministra Zdrowia z dnia 12 grudnia 2022 r. w sprawie testów eksploatacyjnych urządzeń radiologicznych i urządzeń pomocniczych [Regulation of the Minister of Health of 12 December 2022 on operational tests of radiological devices and auxiliary devices]. Dz.U. 2022 poz. 2759
  15. Sander T. Air kerma and absorbed dose standards for reference dosimetry in brachytherapy. BJR. 2014;87(1041):20140176. https://doi.org/10.1259/bjr.20140176
DOI: https://doi.org/10.2478/pjmpe-2024-0032 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Submitted on: Sep 30, 2024
Accepted on: Nov 6, 2024
Published on: Dec 23, 2024
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2024 Piotr Pawłowski, Magdalena Szymko, Paweł Wołowiec, Janusz Braziewicz, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.