Evaluation of the usefulness of small detectors made of Gafchromic EBT3 film for measurements in areas with high dose gradient and without charged-particle equilibrium (CPE) Cover

Evaluation of the usefulness of small detectors made of Gafchromic EBT3 film for measurements in areas with high dose gradient and without charged-particle equilibrium (CPE)

Open Access
|Oct 2024

References

  1. Miften M, Olch A, Mihailidis D, et al. Tolerance limits and methodologies for<scp>IMRT</scp>measurement‐based verification QA Recommendations of AAPM Task Group No. 218. Medical Physics. 2018;45(4). doi:10.1002/mp.12810
  2. Oinam AS, Singh L. Verification of IMRT dose calculations using AAA and PBC algorithms in dose buildup regions. J Applied Clin Med Phys. 2010;11(4):105-121. doi:10.1120/jacmp.v11i4.3351
  3. Wang L, Cmelak AJ, Ding GX. A simple technique to improve calculated skin dose accuracy in a commercial treatment planning system. J Applied Clin Med Phys. 2018;19(2):191-197. doi:10.1002/acm2.12275
  4. Cao Y, Yang X, Yang Z, et al. Superficial dose evaluation of four dose calculation algorithms. Radiation Physics and Chemistry. 2017;137:23-28. doi:10.1016/j.radphyschem.2016.02.032
  5. Bennie N, Metcalfe P. Practical IMRT QA dosimetry using Gafchromic film: a quick start guide. Australas Phys Eng Sci Med. 2016;39(2):533-545. doi:10.1007/s13246-016-0443-0
  6. Borca VC, Pasquino M, Russo G, et al. Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification. J Applied Clin Med Phys. 2013;14(2):158-171. doi:10.1120/jacmp.v14i2.4111
  7. Marrazzo L, Zani M, Pallotta S, et al. GafChromic® EBT3 films for patient specific IMRT QA using a multichannel approach. Physica Medica. 2015;31(8):1035-1042. doi:10.1016/j.ejmp.2015.08.010
  8. Aland T, Moylan R, Kairn T, Trapp J. Effect of verification imaging on in vivo dosimetry results using Gafchromic EBT3 film. Physica Medica. 2016;32(11):1461-1465. doi:10.1016/j.ejmp.2016.10.020
  9. Kidoń J, Polaczek-Grelik K, Gołba K, Wojakowski W, Ochała A. Calibration of Gafchromic XR-RV3 film under interventional radiology conditions. Polish Journal of Medical Physics and Engineering. 2021;27(2):165-173. doi:10.2478/pjmpe-2021-0020
  10. Chełmiński K, Bulski W, Georg D, et al. Energy dependence of radiochromic dosimetry films for use in radiotherapy verification. Reports of Practical Oncology & Radiotherapy. 2010;15(2):40-46. doi:10.1016/j.rpor.2010.02.003
  11. GAFChromic™ EBT3 film specifications, http://www.gafchromic.com/documents/EBT3_Specifications.pdf
  12. IAEA 2006 Technical Reports Series No. 398, Absorbed Dose Determination In External Beam Radiotherapy (Vienna: International Atomic Energy Agency).
  13. Wołowiec P, Kukołowicz PF. The analysis of the measurement uncertainty with application of small detectors made of Gafchromic EBT films for the range of doses typical for in vivo dosimetry in teleradiotherapy. Radiation Measurements. 2016;92:72-79. doi:10.1016/j.radmeas.2016.08.001
  14. Lewis D, Micke A, Yu X, Chan MF. An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan. Medical Physics. 2012;39(10):6339-6350. doi:10.1118/1.4754797
  15. Niroomand‐Rad A, Blackwell CR, Coursey BM, et al. Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55. Medical Physics. 1998;25(11):2093-2115. doi:10.1118/1.598407
  16. Matney JE, Parker BC, Neck DW, Henkelmann G, Rosen II. Evaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry. J Applied Clin Med Phys. 2010;11(2):198-208. https://doi.org/10.1120/jacmp.v11i2.3165
  17. Devic S, Seuntjens J, Sham E, et al. Precise radiochromic film dosimetry using a flat-bed document scanner. Med Phys. 2005;32(7Part1):2245-2253. doi:10.1118/1.1929253
  18. Schneider CA, Rasband WS, Eliceiri KW. NIH Image to ImageJ: 25 years of image analysis. Nat Methods. 2012;9(7):671-675. https://doi.org/10.1038/nmeth.2089
  19. Dąbrowski R, Drozdyk I, Kukołowicz P. High accuracy dosimetry with small pieces of Gafchromic films. Reports of Practical Oncology & Radiotherapy. 2018;23(2):114-120. doi:10.1016/j.rpor.2018.01.001
  20. Micke A, Lewis DF, Yu X. Multichannel film dosimetry with nonuniformity correction. Med Phys. 2011;38(5):2523-2534. doi:10.1118/1.3576105
  21. JCGM 100:2008, Evaluation of measurement, data—Guide to the expression of uncertainty in measurement, https://www.bipm.org/documents/20126/2071204/JCGM_100_2008_E.pdf
  22. IAEA-TECDOC-1585, Measurement Uncertainty, 2008, https://www-pub.iaea.org/MTCD/Publications/PDF/te_1585_web.pdf.
  23. Essers M, Mijnheer B. In vivo dosimetry during external photon beam radiotherapy. International Journal of Radiation Oncology*Biology*Physics. 1999;43(2):245-259. doi:10.1016/s0360-3016(98)00341-1
  24. Gromczak K, Ostrowska K, Gąska A, Sładek J. The universal validation algorithm of coordinate measuring methods. Measurement Automation Monitoring. 2016;62(4):120-124.
DOI: https://doi.org/10.2478/pjmpe-2024-0018 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 152 - 160
Submitted on: Feb 12, 2024
|
Accepted on: Jun 17, 2024
|
Published on: Oct 3, 2024
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2024 Paweł Wołowiec, Paweł Franciszek Kukołowicz, Krzysztof Buliński, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.