Comparison of fulfilling the criteria for critical organs in irradiation of patients with breast cancer using the deep inspiration breath-hold and free breathing techniques Cover

Comparison of fulfilling the criteria for critical organs in irradiation of patients with breast cancer using the deep inspiration breath-hold and free breathing techniques

Open Access
|Sep 2022

Abstract

Introduction: The aim of the study was to evaluate organ-at-risk dose sparing in treatment plans for patients with left-sided breast cancer irradiated with Deep Inspiration Breath Hold (DIBH) and Free Breathing (FB) techniques.

Material and methods: Twenty patients with left-sided breast cancer were analyzed and divided into two groups. Group A included 10 patients with non-metastatic breast cancer, while group B involved 10 patients with metastatic breast cancer spreading to regional lymph nodes. All patients went through the DIBH coaching. For planning purposes, CT scans were obtained in both DIBH and FB. Mean heart dose (Dmean,heart), mean heart volume receiving 50% of the prescribed dose (V50), V20 (V20L.lung), V10 (V10L.lung) and V5 for left lung (V5L.lung), the volume of the PTV receiving a dose greater than or equal to 95% of the prescribed dose (V95 [%]), the maximum point dose (Dmax), and the volume of PTV receiving 107% of the prescribed dose were reported.

Results: In all 20 analyzed pairs of plans, a reduction by more than half in the mean heart dose in DIBH technique plans was achieved, as well as a significant reduction was found in DIBH plans for the heart V50. In 19 patients, the use of the DIBH technique also reduced the volume of the left lung receiving doses of 20 Gy, 10 Gy, and 5 Gy compared to the FB technique.

Conclusions: Dosimetric analysis showed that the free breathing plans don’t fulfill the criteria for a mean heart dose (group B) and the left lung receiving a 20 Gy dose (group A) compared to the DIBH plans. Radiation therapy of left breast cancer with the use of the DIBH technique results in a significant dose reduction in the heart and also reduces the dose in the left lung in the majority of patients, compared to the FB procedure.

DOI: https://doi.org/10.2478/pjmpe-2022-0018 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 150 - 159
Submitted on: Feb 7, 2022
Accepted on: Aug 12, 2022
Published on: Sep 30, 2022
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2022 Katarzyna Matusiak, Magdalena Mucha, Sylwia Pysklak, Anna Kaczmarek, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.