Have a personal or library account? Click to login
A tool for precise calculation of organ doses in voxelised geometries using GAMOS/Geant4 with a graphical user interface Cover

A tool for precise calculation of organ doses in voxelised geometries using GAMOS/Geant4 with a graphical user interface

Open Access
|Mar 2021

References

  1. 1. Bolch WE, Bouchet LG, Robertson JS, et al. The dosimetry of nonuniform activity distributions-radionuclide S values at the voxel level, MIRD pamphlet No. 17. J Nucl Med. 1999;40:11-36.
  2. 2. Mehdi M, Shahrokh N, Seyed RZ, Ali AP, Mahdi G, Ruhollah GA. A 3D Monte Carlo method for estimation of patient-specific internal organs absorbed dose for 99mTc-hynic-Tyr3-octreotide imaging. World J Nucl Med. 2016;15(2):114-123. https://doi.org/10.1007/s00411-003-0221-810.1007/s00411-003-0221-814730450
  3. 3. Martin C. Voxel-based computational models of real human anatomy: A review. Radiat Environ Biophys. 2004;42:229-235. https://doi.org/10.1007/s00411-003-0221-810.1007/s00411-003-0221-8
  4. 4. Yuan J, Chen Q, Brindle J et al. Investigation of nonuniform dose voxel geometry in Monte Carlo calculations. Technol Cancer Res Treat. 2015;14(4):419-27. https://doi.org/10.1177/153303461454745910.1177/153303461454745925223321
  5. 5. Sharma N, Aggarwal LM. Automated medical image segmentation techniques. J Med Phys. 2010;35(1):3-14. https://doi.org/10.4103/0971-6203.5877710.4103/0971-6203.58777282500120177565
  6. 6. Awais M, Ulas B, Brent F, et al. Segmentation and image analysis of abnormal lungs at CT: current approaches, challenges, and future trends. RadioGraphics. 2015;35:1056-1076. https://doi.org/10.1148/rg.201514023210.1148/rg.2015140232452161526172351
  7. 7. Brent F, Ulas B, Awais M, Ziyue X, Daniel JM. A Review on segmentation of Positron Emission Tomography images. Comput Biol Med. 2014;50:76-96. https://doi.org/10.1016/j.compbiomed.2014.04.01410.1016/j.compbiomed.2014.04.014406080924845019
  8. 8. Paula CG, Paulo TDS, Hélio Y, Gabriel P F GR, Laura F. Reconstruction of segmented human voxel phantoms for skin dosimetry. in International Nuclear Atlantic Conference - INAC (Rio de Janeiro, Brazil) 2009. ISBN: 978-85-99141-03-8
  9. 9. Kramer R,Vieira JW, Khoury HJ, Lima FRA, Fuelle D. All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry. Phys Med Biol. 2003;48:1239-1262. https://doi.org/10.1088/0031-9155/48/10/30110.1088/0031-9155/48/10/30112812444
  10. 10. Chung-Yi H, Lai-Jun L, Pei-Yuan L, Jiing-Yih Li, Wen-Teng Wg, Shang-Chih L. Efficient segmentation algorithm for 3D bone models construction on medical images. Journal of Medical and Biological Engineering. 2010;31(6):375-386.
  11. 11. Xu XG. An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: A review of the fifty-year history. Phys Med Biol. 2014;59(18):233-302. https://doi.org/10.1088/0031-9155/59/18/R23310.1088/0031-9155/59/18/R233416987625144730
  12. 12. Yeon SY, Min CH, Chan HK, Jong HJ. Conversion of ICRP male reference phantom to polygon-surface phantom. Phys. Med. Biol. 2013; 58(19): 6985-7007. https://doi.org/10.1088/0031-9155/58/19/698510.1088/0031-9155/58/19/698524029733
  13. 13.Yeon SY, Min CH, Chan HK, Jong HJ. Dose coefficients of mesh-type ICRP reference computational phantoms for idealized external exposures of photons and electrons. Nuclear Engineering and Technology. 2019;51(3):843-552. https://doi.org/10.1016/j.net.2018.12.00610.1016/j.net.2018.12.006
  14. 14. Apostolakis J, Asai M, Cosmo G, Howard V, Ivanchenko V, Verderi M. Parallel geometries in Geant4: Foundation and recent enhancements. in 2008 IEEE Nuclear Science Symposium Conference Record (Dresden, Germany). 2008;883-886. https://doi.org/10.1109/NSSMIC.2008.477453510.1109/NSSMIC.2008.4774535
  15. 15. Arce P, Rato Mendes P, Lagares JI. GAMOS: a GEANT4-based easy and flexible framework for nuclear medicine applications. in IEEE Proc. Nuc. Sci. Symp. Conf. Rec. 2008; 3162-3168. https://doi.org/10.1109/NSSMIC.2008.477502310.1109/NSSMIC.2008.4775023
  16. 16. Arce P, Lagares JI, Harkness L, et al. Gamos: A framework to do Geant4 simulations in different physics fields with a user-friendly interface. Nuc Instr Meth Section A. 2014;735:304. https://doi.org/10.1016/j.nima.2013.09.03610.1016/j.nima.2013.09.036
  17. 17. Schneider U, Pedroni E, Lomax A. The calibration of CT Hounsfield units for radiotherapy treatment planning. Phys Med Biol. 1996;41(1):111-124. https://doi.org/10.1088/0031-9155/41/1/00910.1088/0031-9155/41/1/0098685250
  18. 18. Geant4 Collaboration. Geant4 Book For Application Developer,” Available at: http://geant4-userdoc.web.cern.ch/geant4-userdoc/UsersGuides/ForApplicationDeveloper/html/index.html (Accessed: 1 January, 2020).
DOI: https://doi.org/10.2478/pjmpe-2021-0005 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 31 - 40
Published on: Mar 18, 2021
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 times per year

© 2021 Pedro Arce Dubois, Nguyen Thi Phuong Thao, Nguyen Thien Trung, Juan Diego Azcona, Pedro-Borja Aguilar-Redondo, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.