Have a personal or library account? Click to login
Conversion coefficients from fluence and air kerma to personal dose equivalent for monoenergetic photons using analytical fit and Monte Carlo simulation Cover

Conversion coefficients from fluence and air kerma to personal dose equivalent for monoenergetic photons using analytical fit and Monte Carlo simulation

Open Access
|Apr 2020
DOI: https://doi.org/10.2478/pjmpe-2020-0004 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 31 - 44
Submitted on: Sep 4, 2019
Accepted on: Feb 17, 2020
Published on: Apr 3, 2020
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2020 Hassan Al Kanti, O. El Hajjaji, T. El Bardouni, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.