Automated MTF measurement in CT images with a simple wire phantom Cover

References

  1. [1] Verdun FR, Racine D, Ott JG, et al. Image quality in CT: From physical measurements to model observers. Phys Med. 2015;31(8):823-843.10.1016/j.ejmp.2015.08.00726459319
  2. [2] International Atomic Energy Agency. Status of computed tomography: Dosimetry for wide cone beam scanners. IAEA-Human Health Reports No 5. 2011.
  3. [3] Kalender WA, Seissler W, Klotz E, Vock P. Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology. 1990;176(1):181-183.10.1148/radiology.176.1.23530882353088
  4. [4] McCollough CH, Zink FE. Performance evaluation of a multi-slice CT system. Med Phys. 1999;26(11):2223-2230.10.1118/1.59877710587202
  5. [5] McNitt-Gray MF. AAPM/RSNA physics tutorial for residents: topics in CT—radiation dose in CT. RadioGraphics. 2002;22(6):1541-1553.10.1148/rg.22602512812432127
  6. [6] Primak AN, McCollough CH, Bruesewitz MR, et al. Relationship between noise, dose, and pitch in cardiac multi–detector row CT. RadioGraphics. 2006;26(6):1785-1794.10.1148/rg.26606506317102050
  7. [7] Wilson JM, Christianson OI, Richard S, Samei E. A methodology for image quality evaluation of advanced CT systems. Med Phys. 2013;40(3):031908.10.1118/1.479164523464323
  8. [8] Anam C, Haryanto F, Widita R, Arif I. New noise reduction method for reducing CT scan dose: Combining Wiener filtering and edge detection algorithm. AIP Conference Proceedings. 2015;1677:040004.10.1063/1.4930648
  9. [9] McCollough CH, Bruesewitz MR, McNitt-Gray MF, et al. The phantom portion of the American College of Radiology (ACR) Computed Tomography (CT) accreditation program: Practical tips, artifact examples, and pitfalls to avoid. Med Phys. 2004;31(9):2423-2442.10.1118/1.176963215487722
  10. [10] Kayugawa A, Ohkubo M, Wada S. Accurate determination of CT point-spread-function with high precision. J Appl Clin Med Phys. 2013;14(4):216-226.10.1120/jacmp.v14i4.3905571453923835372
  11. [11] Friedman SN, Fung GSK, Siewerdsen JH, Tsui BMW. A simple approach to measure computed tomography (CT) modulation transfer function (MTF) and noise-power spectrum (NPS) using the American College of Radiology (ACR) accreditation phantom. Med Phys. 2013;40(5):051907.10.1118/1.4800795364398423635277
  12. [12] Judy PF. The line spread function and modulation transfer function of a computed tomographic scanner. Med Phys. 1976;3(4):233-236.10.1118/1.594283785200
  13. [13] Droege RT, Morin RL. A practical method to measure the MTF of CT scanners. Med Phys. 1982;9(5):758-760.10.1118/1.5951247155079
  14. [14] Nickoloff EL Riley R. A simplified approach for modulation transfer function determinations in computed tomography. Med Phys. 1985;12(4):437-442.10.1118/1.5957064033588
  15. [15] Samei E, Ranger NT, Dobbins JT, Chen Y. Intercomparison of methods for image quality characterization. I. Modulation transfer function. Med Phys. 2006;33(5):1454-1465.10.1118/1.2188819
  16. [16] Narváez M, Graffigna JP, Gómez ME, Romo R. Application of oversampling to obtain the MTF of digital radiology equipment. J Phys Conf Ser. 2016;705(1):012057.10.1088/1742-6596/705/1/012057
  17. [17] Takenaga T, Katsuragawa S, Goto M, et al. Modulation transfer function measurement of CT images by use of a circular edge method with a logistic curve-fitting technique. Radiol Phys Technol. 2015;8(1):53-59.10.1007/s12194-014-0286-x25142743
  18. [18] Ichikawa K, Hara T, Niwa S, Ohashi K. Method of measuring modulation transfer function using metal wire in computed tomography. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2008;64(6):672-680.10.6009/jjrt.64.67218648156
  19. [19] Anam C, Fujibuchi T, Budi WS, et al. An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: Impact of field of view on spatial resolution of CT images. J Appl Clin Med Phys. 2018;19(6):244-252.10.1002/acm2.12476623684130338920
  20. [20] Jun-Yan R, Guo-Tao F, Cun-Feng W, et al. Measurement of spatial resolution of the micro-CT system. Chinese Physics C. 2010;34(3):412-416.10.1088/1674-1137/34/3/022
  21. [21] Arabi H, Asl ARK, Aghamiri SM. The effect of focal spot size on the spatial resolution of variable resolution X-ray CT Scanner. Iran J Radiat Res. 2010;8(1):37-43.10.1109/ICBME.2010.5704967
  22. [22] Venema HW. Modulation transfer functions of single-slice and dual-slice computed tomography scanners. Med Phys. 1996;23(11):1863-1864.10.1118/1.5978988947898
  23. [23] Löve A, Olsson M-L, Siemund R, et al. Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels. Br J Radiol. 2013;86:20130388.10.1259/bjr.20130388383043624049128
  24. [24] Dodge CT, Tamm EP, Cody DD, et al. Performance evaluation of iterative reconstruction algorithms for achieving CT radiation dose reduction – a phantom study. J Appl Clin Med Phys. 2016;17(2):511-531.10.1120/jacmp.v17i2.5709587504627074454
  25. [25] Anam C, Haryanto F, Widita R, et al. An investigation of spatial resolution and noise in reconstructed CT images using iterative reconstruction (IR) and filtered back-projection (FBP). J Phys Conf Series. 2019;1127:012016.10.1088/1742-6596/1127/1/012016
  26. [26] Sanders J, Hurwitz L, Samei E. Patient-specific quantification of image quality: An automated method for measuring spatial resolution in clinical CT images. Med Phys. 2015;43(10):5330-5338.10.1118/1.496198427782718
  27. [27] Mori I, Machida Y. Deriving the modulation transfer function of CT from extremely noisy edge profiles. Radiol Phys Technol. 2009;2(1):22-32.10.1007/s12194-008-0039-920821125
  28. [28] Garayoa J, Castro P. A study on image quality provided by a kilovoltage cone-beam computed tomography. J Appl Clin Med Phys. 2013;14(1):239-257.10.1120/jacmp.v14i1.3888571405223318380
  29. [29] Boone JM, Seibert JA. An analytical edge spread function model for computer fitting and subsequent calculation of the LSF and MTF. Med Phys. 1994;21(1):1541-1545.10.1118/1.597264
  30. [30] CIRS. AAPM CT Performance Phantom Model 610. http://www.cirsinc.com/wp-content/uploads/2019/04/610-DS-120418.pdf
  31. [31] Sun Nuclear. CT ACR 464 Phantom. https://www.sunnuclear.com/documents/datasheets/gammex/CTACRPhantom_D013118.pdf
  32. [32] The Phantom Laboratory. Catphan® 500 and 600 Manual. https://imagingequipment.co.uk/wp-content/uploads/2017/10/Catphan-500600-Manual.pdf
  33. [33] Anam C, Budi WS, Fujibuchi T, et al. Validation of the tail replacement method in MTF calculations using the homogeneous and non-homogeneous edges of a phantom. J Phys Conf Series 2019;1248:012001.10.1088/1742-6596/1248/1/012001
  34. [34] Yin FF, Giger ML, Doi K. Measurement of presampling modulation transfer function of film digitizers using a curve fitting technique. Med Phys. 1990;17(6):962-966.10.1118/1.5964632280739
  35. [35] Anam C, Fujibuchi T, Toyoda T, et al. An investigation of a CT noise reduction using a modified of wiener filtering-edge detection. J Phys Conf Series. 2019;1217:012022.10.1088/1742-6596/1217/1/012022
  36. [36] Ohkubo M, Wada S, Matsumoto T, Nishizawa K. An effective method to verify line and point spread functions measured in computed tomography. Med Phys. 2006;33(8):2757-2764.10.1118/1.221416816964851
  37. [37] Hsieh J. Computed tomography: principles, design artifacts, and recent advances. Bellingham: SPIE; 2003.
DOI: https://doi.org/10.2478/pjmpe-2019-0024 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 179 - 187
Submitted on: Mar 7, 2019
|
Accepted on: Jul 30, 2019
|
Published on: Aug 28, 2019
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2019 Choirul Anam, Toshioh Fujibuchi, Freddy Haryanto, Wahyu Setia Budi, Heri Sutanto, Kusworo Adi, Zaenul Muhlisin, Geoff Dougherty, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.