Have a personal or library account? Click to login
Signal suppressions of grape syrup and grape syrup/lemon aqueous solutions in magnetic resonance cholangiopancreatography using heavily T2-weighted pulse sequence Cover

Signal suppressions of grape syrup and grape syrup/lemon aqueous solutions in magnetic resonance cholangiopancreatography using heavily T2-weighted pulse sequence

Open Access
|Aug 2019

References

  1. [1] Govindarajan A, Lakshmanan PM, Sarawagi R, Prabhakaran V. Evaluation of date syrup as an oral negative contrast agent for MRCP. Am J Roentgenol. 2014;203(5):1001-1005.10.2214/AJR.13.12299
  2. [2] Griffin N, Charles-Edwards G, Grant LA. Magnetic resonance cholangiopancreatography: the ABC of MRCP. Insights Imaging. 2012;3(1):11-21.10.1007/s13244-011-0129-9
  3. [3] Frisch A, Walter TC, Hamm B, Denecke T. Efficacy of oral contrast agents for upper gastrointestinal signal suppression in MRCP: A systematic review of the literature. Acta Radiol Open. 2017;6(9):1-7.10.1177/2058460117727315
  4. [4] Giovagnoni A, Fabbri A, Maccioni F. Oral contrast agents in MRI of the gastrointestinal tract. Abdom Imaging. 2002;27(4):367-375.10.1007/s00261-001-0117-5
  5. [5] Chavhan GB, Babyn PS, Manson D, Vidarsson L. Pediatric MR cholangiopancreatography: principles, technique, and clinical applications. Radiographics. 2008;28(7):1951-1962.10.1148/rg.287085031
  6. [6] Chan JHM, Tsui EYK, Yuen MK, et al. Gadopentetate dimeglumine as an oral negative gastrointestinal contrast agent for MRCP. Abdom Imaging. 2000;25(4):405-408.10.1007/s002610000018
  7. [7] Gong J, Zhao H, Liu T, et al. Value of MRCP using oral Gd-DTPA as negative contrast materials in diagnosis of atypical juxtapapillary duodenal diverticulum. Clin Imag. 2009;33(5):361-364.10.1016/j.clinimag.2009.05.006
  8. [8] Kato J, Kawamura Y, Watanabe T, et al. Examination of intra-gastrointestinal tract signal elimination in MRCP: Combined use of T1-shortening positive contrast agent and single-shot fast inversion recovery. J Magn Reson Imaging. 2001;13(5):738-743.10.1002/jmri.1102
  9. [9] Riordan RD, Khonsari M, Jeffries J, et al. Pineapple juice as a negative oral contrast agent in magnetic resonance cholangiopancreatography: a preliminary evaluation. Br J Radiol. 2004;77(924):991-999.10.1259/bjr/36674326
  10. [10] Papanikolaou N, Karantanas A, Maris T, Gourtsoyiannis N. MR cholangiopancreatography before and after oral blueberry juice administration. J Comput Assist Tomogr. 2000;24(2):229-234.10.1097/00004728-200003000-00008
  11. [11] Chu ZQ, Ji Q, Zhang JL. Orally administered lemon/orange juice improved MRCP imaging of pancreatic ducts. Abdom Imaging. 2010;35(3):367-371.10.1007/s00261-009-9514-y
  12. [12] Sanchez TA, Elias Jr J, Colnago LA, et al. Clinical feasibility of Acai (Euterpe oleracea) pulp as an oral contrast agent for magnetic resonance cholangiopancreatography. J Comput Assist Tomogr. 2009;33(5):666-671.10.1097/RCT.0b013e31819012a0
  13. [13] Pinho KEP, Pinho AC, Pisani JC, et al. Açai juice as contrast agent in MRCP exams: qualitative and quantitative image evaluation. Braz Arch Biol Technol. 2019;62:e19160697.10.1590/1678-4324-2019160697
  14. [14] Ghanaati H, Rokni-Yazdi H, Jalali AH, et al. Improvement of MR cholangiopancreatography (MRCP) images after black tea consumption. Eur Radiol. 2011;21(12):2551-2557.10.1007/s00330-011-2217-0
  15. [15] Mikkelsen D, Watson J, Vallø J. The use of banana in MRCP. Acta Radiol. 2005;46(2):215-216.10.1080/02841850510021139
  16. [16] Coppens E, Metens T, Winant C, Matos C. Pineapple juice labeled with gadolinium: a convenient oral contrast for magnetic resonance cholangiopancreatography. Eur Radiol. 2005;15(10):2122-2129.10.1007/s00330-005-2835-5
  17. [17] Duarte JA, Furtado AP, Marroni CA. Use of pineapple juice with gadopentetate dimeglumine as a negative oral contrast for magnetic resonance cholangiopancreatography: a multicentric study. Abdom Imaging. 2012;37(3):447-456.10.1007/s00261-011-9761-6
  18. [18] Chen CW, Liu YS, Chen CY, et al. Use of carbon dioxide as negative contrast agent for magnetic resonance cholangiopancreatography. World J Radiol. 2011;3(2):47-50.10.4329/wjr.v3.i2.47
  19. [19] Bittman ME, Callahan MJ. The effective use of acai juice, blueberry juice and pineapple juice as negative contrast agents for magnetic resonance cholangiopancreatography in children. Pediatr Radiol. 2014;44(7):883-887.10.1007/s00247-014-2884-5
  20. [20] Kinner S, Dechêne A, Ladd SC, et al. Comparison of different MRCP techniques for the depiction of biliary complications after liver transplantation. Eur Radiol. 2010;20(7):1749-1756.10.1007/s00330-010-1714-x
  21. [21] Nakaura T, Kidoh M, Maruyama N, et al. Usefulness of the SPACE pulse sequence at 1.5 T MR cholangiography: Comparison of image quality and image acquisition time with conventional 3D-TSE sequence. J Magn Reson Imaging. 2013;38(5):1014-1019.10.1002/jmri.24033
  22. [22] Kim JH, Hong SS, Eun HW, et al. Clinical usefulness of free-breathing navigator-triggered 3D MRCP in non-cooperative patients: comparison with conventional breath-hold 2D MRCP. Eur J Radiol. 2012;81(4):e513-518.10.1016/j.ejrad.2011.06.004
DOI: https://doi.org/10.2478/pjmpe-2019-0020 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 149 - 154
Submitted on: Jun 12, 2019
Accepted on: Aug 12, 2019
Published on: Aug 28, 2019
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2019 Mahdi Asgari, Baharak Divband, Nahideh Gharehaghaji, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.