Have a personal or library account? Click to login
Ultraviolet ray irradiation duration for the pre-exposure of Gafchromic EBT2 Cover

Ultraviolet ray irradiation duration for the pre-exposure of Gafchromic EBT2

Open Access
|Dec 2018

Abstract

The strength and density change of the ultraviolet (UV) ray of Gafchromic EBT2 were investigated. Previous studies suggested that UV-A rays can be substituted for the x-ray double-exposure technique to correct Gafchromic EBT2’s non-uniformity error. In this study, we aimed to determine the appropriate strength of UV-A rays for irradiating an active layer that would correct the non-uniformity error of Gafchromic EBT2.

UV-A rays with a wavelength of 375 nm were used to irradiate Gafchromic EBT2 in various durations, and the resulting density change was investigated. To correct Gafchromic EBT2’s non-uniformity error, a pre-irradiation with a UV-A lamp was conducted at a distance of 72 cm for 30 min. To determine the most appropriate irradiation duration, a UV light-emitting diode generating UV-A of 375 nm was used to irradiate the Gafchromic EBT2 film with varying durations of 1, 2, 3, 4, 5, 10, 15, 20, 25, and 30 min at a distance of 5.3 cm. A 12.7 diameter region of interest was set by the irradiation area, and a histogram of pixel values was created. The condition options were decided based on two important requirements: 1) no zero values of the mode and seconds exist, and 2) the 1/10 value of the mode intersects both histogram sleeves.

In the case of Gafchromic EBT2, the irradiation strength was 85.43 mJ/cm2 for one minute in which the pixel value of mean ± SD was 255.34 ± 213.29. The irradiation duration of 4 min was the border duration of the above two conditions. When a UV ray of 375 nm wavelength is used to irradiate Gafchromic EBT2 as a substitute for x-ray exposure, the 4-min pre-irradiation duration (341.74 mJ/cm2) is demonstrably sufficient.

DOI: https://doi.org/10.2478/pjmpe-2018-0026 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 189 - 193
Submitted on: Feb 26, 2018
Accepted on: Sep 29, 2018
Published on: Dec 24, 2018
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2018 Toshizo Katsuda, Rumi Gotanda, Tatsuhiro Gotanda, Takuya Akagawa, Nobuyoshi Tanki, Tadao Kuwano, Atsushi Noguchi, Kouichi Yabunaka, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.