Influence of ultrasound on the clearance of toxic substances from Polysulfone hollow fiber membrane used in a dialyzer filter Cover

Influence of ultrasound on the clearance of toxic substances from Polysulfone hollow fiber membrane used in a dialyzer filter

Open Access
|Oct 2018

References

  1. [1] Himmelfarb J, Ikizler TA. Hemodialysis. N Eng J Med. 2010;363(19):1833-1845.10.1056/NEJMra0902710
  2. [2] Mineshima M. The past, present and future of the dialyzer. Contrib Nephrol. 2015;185:8-14.10.1159/000380965
  3. [3] Röckel A, Hertel J, Fiegel P, et al. Permeability and secondary membrane formation of a high flux polysulfone hemofilter. Kidney Int. 1986;30(3):429-432.10.1038/ki.1986.202
  4. [4] Nii S, Oketani S, Kawaizumi F, Takahashi K. Effects of Ultrasonic Irradiation on Solute Permeation through a Dialysis Membrane. J Chem Eng Japan. 2005;38(7):497-501.10.1252/jcej.38.497
  5. [5] Li H, Ohdaira E, Ide M. Enhancement in Diffusion of Electrolyte through Membrane Using Ultrasonic Dialysis Equipment with Plane Membrane. Jap J Appl Phys. 1995;34(5S):2725.10.1143/JJAP.34.2725
  6. [6] Cai M, Li W, Liang H. Effects of ultrasound parameters on ultrasound-assisted ultrafiltration using cross-flow hollow fiber membrane for Radix astragalus extracts. ChemEng Proc: Process Intensification. 2014;86:30-35.10.1016/j.cep.2014.10.008
  7. [7] Lamminen MO, Walker HW, Weavers LK. Cleaning of particle-fouled membranes during cross-flow filtration using an embedded ultrasonic transducer system. J Membr Sci. 2006;283(1-2):225-232.10.1016/j.memsci.2006.06.034
  8. [8] Li J, Hallbauer DK, Sanderson RD. Direct monitoring of membrane fouling and cleaning during ultrafiltration using a non-invasive ultrasonic technique. J Membr Sci. 2003;215(1-2):33-52.10.1016/S0376-7388(02)00600-2
  9. [9] Maskooki A, Kobayashi T, Mortazavi SA, Maskooki A. Effect of low frequencies and mixed wave of ultrasound and EDTA on flux recovery and cleaning of microfiltration membranes. Sep Purif Technol. 2008;59(1):67-73.10.1016/j.seppur.2007.05.028
  10. [10] Masselin I, Chasseray X, Durand-Bourlier L, et al. Effect of sonication on polymeric membranes. J Membr Sci. 2001;181(2):213-220.10.1016/S0376-7388(00)00534-2
  11. [11] Jin W, Guo W, LÜ X, et al. Effect of the Ultrasound Generated by Flat Plate Transducer Cleaning on Polluted Polyvinylidenefluoride Hollow Fiber Ultrafiltration Membrane. Chin J Chem Eng. 2008;16(5):801-804.10.1016/S1004-9541(08)60159-7
  12. [12] Wang X-l, Li X-f, Fu X-q, et al. Effect of ultrasound irradiation on polymeric microfiltration membranes. Desalination. 2005;175(2):187-196.10.1016/j.desal.2004.08.044
  13. [13] Kyllönen H, Pirkonen P, Nyström M, et al. Experimental aspects of ultrasonically enhanced cross-flow membrane filtration of industrial wastewater. Ultrason Sonochem. 2006;13(4):295-302.10.1016/j.ultsonch.2005.04.006
  14. [14] Cai M, Zhao S, Liang H. Mechanisms for the enhancement of ultrafiltration and membrane cleaning by different ultrasonic frequencies. Desalination. 2010;263(1-3):133-138.10.1016/j.desal.2010.06.049
  15. [15] Kyllönen HM, Pirkonen P, Nyström M. Membrane filtration enhanced by ultrasound: a review. Desalination. 2005;181(1-3):319-335.10.1016/j.desal.2005.06.003
  16. [16] Li X, Yu J, Nnanna AGA. Fouling mitigation for hollow-fiber UF membrane by sonication. Desalination. 2011;281:23-29.10.1016/j.desal.2011.07.036
  17. [17] Chai X, Kobayashi T, Fujii N. Ultrasound-associated cleaning of polymeric membranes for water treatment. Sep Purif Technol. 1999;15(2):139-46.10.1016/S1383-5866(98)00091-4
  18. [18] Chai X, Kobayashi T, Fujii N. Ultrasound effect on cross-flow filtration of polyacrylonitrile ultrafiltration membranes. J Membr Sci. 1998;148(1):129-135.10.1016/S0376-7388(98)00145-8
  19. [19] Shiran MB, Barzegar Marvasti M, Shakeri-Zadeh A, et al. Enhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound. J Biomed Phys Eng. 2017;7(2):107-116.
  20. [20] Care FM. Dialysers and Filters Product Range. In: Care FM, editor. Deutschland GmbH 2007.
  21. [21] Care FM. Fresenius Polysulfone High-Flux Dialyzers. In: Care FM, editor. Deutschland GmbH
  22. [22] Watmough DJ, Quan KM, Shiran M, editors. The Sarvazyan method of mapping ultrasound fields. IEE Colloquium on Ultrasound Instrumentation; 1990 10 May 1990.
  23. [23] van der Sande FM, Wystrychowski G, Kooman JP, et al. Control of Core Temperature and Blood Pressure Stability during Hemodialysis. Clin J Am Soc Nephrol. 2009;4(1):93-98.10.2215/CJN.01800408
  24. [24] Hesson JR. Fundamentls of Ultrasound Cleaning. United States: Hessonic Ultrasounic.
  25. [25] Kobayashi T, Kobayashi T, Hosaka Y, Fujii N. Ultrasound-enhanced membrane-cleaning processes applied water treatments: influence of sonic frequency on filtration treatments. Ultrasonics. 2003;41(3):185-190.10.1016/S0041-624X(02)00462-6
  26. [26] Parker PM. Hemodialysis, A Medical Dictionary, Bibliography and Annotated Research Guide to Internet References. ICON Health Publications; 2004. 408 p.
  27. [27] Li H,, Ohdaira E, Ide M. Effect of Ultrasonic Irradiation on Permeability of Dialysis Membrane. Jap J Appl Phys. 1996;35(5S):3255.10.1143/JJAP.35.3255
DOI: https://doi.org/10.2478/pjmpe-2018-0012 | Journal eISSN: 1898-0309 | Journal ISSN: 1425-4689
Language: English
Page range: 91 - 97
Submitted on: Feb 2, 2018
Accepted on: Jun 28, 2018
Published on: Oct 4, 2018
Published by: Polish Society of Medical Physics
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2018 Behrouz Rasuli, Naser Tabkhi, Ebrahim Kalantar, Vahid Zarezade, Mohammad Bagher shiran, published by Polish Society of Medical Physics
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.