Abstract

The Timepix2-based hybrid-pixel detector with a 500 μm thick silicon sensor was employed for fast-neutrons registration to be applied in neutron radiography of metallic printed circuit heat exchanger (PCHE). Two energies of neutrons were experimentally tested. The detection of 3.55 MeV neutrons from the deuteron–deuteron (DD) reaction was compared to 15.7 MeV neutrons from the deuteron–tritium (DT) neutron generator. In order to distinguish the signal induced by the registered neutrons from the accelerator background, filtration of the recorded particle spectral tracks was applied. The benefit of applying hydrogen-based converter layer for 3.55 MeV neutrons was observable. On the other hand, in the case of 15.7 MeV neutrons, the direct registration by interaction with the sensor Si significantly dominates the conversion.

DOI: https://doi.org/10.2478/nuka-2024-0020 | Journal eISSN: 1508-5791 | Journal ISSN: 0029-5922
Language: English
Page range: 135 - 140
Submitted on: Nov 21, 2023
|
Accepted on: May 8, 2024
|
Published on: Jun 25, 2024
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2024 Andrea Šagátová, Marko Fülöp, Andrej Novák, Branislav Vrban, Jakub Lüley, Štefan Čerba, Ivan Benkovský, Bohumír Zaťko, published by Institute of Nuclear Chemistry and Technology
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.