Full-scale Test of an Unreinforced Concrete Dome Plug for the Spent Nuclear Fuel Repository Cover

Full-scale Test of an Unreinforced Concrete Dome Plug for the Spent Nuclear Fuel Repository

By: Richard Malm  
Open Access
|Dec 2018

Abstract

In the planned Swedish repository for spent nuclear fuel, plugs are designed to close the deposition tunnels. The outer part of these plugs consists of a concrete dome made with self-compacting-concrete, designed to have low pH to reduce negative effects on the bentonite clay buffer. A full-scale test has been performed to evaluate the performance of the plug, to test the installation and to verify underlying design assumptions. In this paper, the behaviour of the concrete dome is evaluated based on measurements, from casting the concrete until it was subjected to 4 MPa hydrostatic water pressure.

DOI: https://doi.org/10.2478/ncr-2018-0004 | Journal eISSN: 2545-2819 | Journal ISSN: 0800-6377
Language: English
Page range: 55 - 75
Submitted on: Mar 18, 2018
Accepted on: May 15, 2018
Published on: Dec 1, 2018
Published by: Nordic Concrete Federation
In partnership with: Paradigm Publishing Services
Publication frequency: 2 issues per year

© 2018 Richard Malm, published by Nordic Concrete Federation
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.