References
- Morucci JP, Rigaud B. Bioelectrical impedance techniques in medicine part III: Impedance imaging third section: Medical applications. Critical Reviews in Biomedical Engineering. 24(4-6);655-677:1996. https://doi.org/10.1615/CritRevBiomedEng.v24.i4-6.60
- Rabbani KS, Kadir MA. Possible applications of Focused Impedance Method (FIM) in biomedical and other areas of study. Bangladesh Journal of Medical Physics. 4(1);67-74: 2011. https://doi.org/10.3329/bjmp.v4i1.14689
- Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Physics in Medicine & Biology. 41(11);2251:1996. https://doi.org/10.1088/0031-9155/41/11/002
- Khalil SF, Mohktar MS, Ibrahim F. The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases. Sensors. 14(6); 10895-10928: 2014. https://doi.org/10.3390/s140610895
- Thomasset A. Bio-electric properties of tissues. Estimation by measurement of impedance of extracellular ionic strength and intracellular ionic strength in the clinic. Lyon Médical. 209; 1325-1350:1963.
- Lingwood BE, Colditz PB, Ward, LC. Biomedical applications of electrical impedance analysis. In ISSPA'99. Proceedings of the Fifth International Symposium on Signal Processing and its Applications (IEEE Cat.No. 99EX359). 1; 367-370:1999. https://doi.org/10.1109/ISSPA.1999.818188
- Martinsen ØG, Grimnes S. The concept of transfer impedance in bioimpedance measurements. In 4th European Conference of the International Federation for Medical and Biological Engineering. 1078-1079:2009 (pp. 1078-1079). https://doi.org/10.1007/978-3-540-89208-3_257
- Rabbani KS, Sarker M, Akond M, Akter T. Focused impedance measurement (FIM): a new technique with improved zone localization. Annals of the New York Academy of Sciences. 873;408-420:1999. https://doi.org/10.1111/j.1749-6632.1999.tb09490.x
- Rabbani KS, Karal MA. A new four-electrode Focused Impedance Measurement (FIM) system for physiological study. Annals of Biomedical Engineering. 36(6);1072-1077: 2008. https://doi.org/10.1007/s10439-008-9470-7
- Rabbani KS. Focused Impedance Method: Basics and Applications. In: Simini F., Bertemes-Filho P. (eds) Bioimpedance in Biomedical Applications and Research. Springer, Cham; 2018 pp. 137-185. https://doi.org/10.1007/978-3-319-74388-2_9.
- Islam N, Rabbani KS, Wilson AJ. The sensitivity of focused electrical impedance measurements, Physiological Measurement. 31;S97-S109:2010. https://doi.org/10.1088/0967-3334/31/8/s08
- Rabbani KS. Simple electrode configurations for probing deep organs using Electrical Bio-Impedance techniques. Bangladesh Journal of Medical Physics. 11(1);1-5:2019. https://doi.org/10.3329/bjmp.v11i1.44053
- Mobarak M, Rabbani KS. Improving the sensitivity at the center of lung by using Focused Impedance Method. SEU Journal of Science and Engineering. 13(1):2019.
- Mobarak M, Rabbani KS. Improving deep sensitivity of Four-Electrode Focused Impedance Method in lungs by varying electrode geometries. Bangladesh Journal of Medical Physics. 15(1);43-54:2022. https://doi.org/10.3329/bjmp.v15i1.63561
- Roy SK, Karal MA, Kadir MA, Rabbani KS. A new six-electrode electrical impedance technique for probing deep organs in the human body. European Biophysics Journal. 48(8);711-719:2019. https://doi.org/10.1007/s00249-019-01396-x
- Khanal T, Rabbani KS. Sensitivity study of a locally developed six electrode focused impedance method. Journal of Electrical Bioimpedance. 15(1);33-40:2024. https://doi.org/10.2478/joeb-2024-0005
- Mobarak M, Kadir MA, Rabbani KS. Probing deep lung regions using a new 6-electrode tetrapolar impedance method. Journal of Electrical Bioimpedance. 13(1);116-124:2022. https://doi.org/10.2478/joeb-2022-0016
- Haque R, Kadir MA, Rabbani KS. Probing for stomach using the Focused Impedance Method (FIM). Journal of Electrical Bioimpedance. 10(1);73-82:2019. https://doi.org/10.2478/joeb-2019-0011
- Grimnes S, Martinsen ØG. Bioelectricity and bioimpedance basics. 2nd edition. Academic Press.