Recognition of lung volume condition based on phase space mapping using electrical impedance tomography Cover

Recognition of lung volume condition based on phase space mapping using electrical impedance tomography

Open Access
|Aug 2019

Figures & Tables

Fig. 1

Lungs Classification to four regions.
Lungs Classification to four regions.

Fig. 2

Electrical Impedance Tomography of lung’s four regions.
Electrical Impedance Tomography of lung’s four regions.

Fig. 3

Phase space mapping.
Phase space mapping.

Fig. 4

A phase space mapping for suitable lung volume.
A phase space mapping for suitable lung volume.

Fig. 5

A phase space mapping for unsuitable lung volume.
A phase space mapping for unsuitable lung volume.

Fig 6

Comparison of the SD1 parameter for different value of the τ.
Comparison of the SD1 parameter for different value of the τ.

Fig. 7

Comparison of the SD2 parameter for different value of the τ.
Comparison of the SD2 parameter for different value of the τ.

The average and the standard deviation of the SD1 and SD2 parameters with τ = 6_

Lung Volume ConditionsSD1SD2
Mean ± Standard deviationMean ± Standard deviation
Unacceptable156.71 ± 26.012457.98 ± 245.54
Suitable342.32 ± 57.752113.18 ± 230.67

The average and the standard deviation of the SD1 and SD2 parameters with τ = 3_

Lung Volume ConditionsSD1SD2
Mean ± Standard deviationMean ± Standard deviation
Unacceptable118.19 ± 15.752217.25 ± 228.51
Suitable158.09 ± 34.121835.12± 216.41

The average and the standard deviation of the SD1 and SD2 parameters with τ = 2_

Lung Volume ConditionsSD1SD2
Mean ± Standard deviationMean ± Standard deviation
Unacceptable96.51 ± 12.102104.23 ± 223.25
Suitable112.67 ± 24.091716.06± 213.43

The average and the standard deviation of the SD1 and SD2 parameters with τ = 5_

Lung Volume ConditionsSD1SD2
Mean ± Standard deviationMean ± Standard deviation
Unacceptable148.20 ± 24.172418.23 ± 239.67
Suitable297.41 ± 49.252098.27 ± 226.15

The average and the standard deviation of the SD1 and SD2 parameters with τ = 4_

Lung Volume ConditionsSD1SD2
Mean ± Standard deviationMean ± Standard deviation
Unacceptable132.54 ± 21/142375.78 ± 234.01
Suitable216.37 ± 41/621932.64± 220.17

The average and the standard deviation of the SD1 and SD2 parameters with τ = 1_

Lung Volume ConditionsSD1SD2
Mean ± Standard deviationMean ± Standard deviation
Unacceptable89.23 ± 10.451914.71 ± 203.61
Suitable94.43 ± 11.7611673.52± 174.11
Language: English
Page range: 34 - 39
Submitted on: Dec 2, 2018
Published on: Aug 20, 2019
Published by: University of Oslo
In partnership with: Paradigm Publishing Services
Publication frequency: 1 times per year

© 2019 Mohammad Karimi Moridani, Fatemeh Choopani, Mandana Kia, published by University of Oslo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.