Have a personal or library account? Click to login
Use of a conical conducting layer with an electrical impedance probe to enhance sensitivity in epithelial tissues Cover

Use of a conical conducting layer with an electrical impedance probe to enhance sensitivity in epithelial tissues

Open Access
|Dec 2018

References

  1. Bertemes-Filho P. Electrical Impedance Spectroscopy. Bioimpedance in Biomedical Applications and Research: Springer; 2018. p. 5-27. https://doi.org/10.1007/978-3-319-74388-2-2
  2. Abdul S, Brown B, Milnes P, Tidy J. A clinical study of the use of impedance spectroscopy in the detection of cervical intraepithelial neoplasia (CIN). Gynecologic Oncology. 2005;99(3):S64-S6. https://doi.org/10.1016/j.ygyno.2005.07.046
  3. Abdul S, Brown B, Milnes P, Tidy J. The use of electrical impedance spectroscopy in the detection of cervical intraepithelial neoplasia. International Journal of Gynecological Cancer. 2006;16(5):1823-32. https://doi.org/10.1111/j.1525-1438.2006.00651.x
  4. Brown BH, Milnes P, Abdul S, Tidy JA. Detection of cervical intraepithelial neoplasia using impedance spectroscopy: a prospective study. BJOG: An International Journal of Obstetrics & Gynaecology. 2005;112(6):802-6. https://doi.org/10.1111/j.1471-0528.2004.00530.x
  5. Murdoch C, Brown BH, Hearnden V, Speight PM, D'Apice K, Hegarty AM, et al. Use of electrical impedance spectroscopy to detect malignant and potentially malignant oral lesions. International journal of nanomedicine. 2014;9:4521. https://doi.org/10.2147/IJN.S64087
  6. Tatullo M, Marrelli M, Amantea M, Paduano F, Santacroce L, Gentile S, et al. Bioimpedance detection of oral lichen planus used as preneoplastic model. Journal of Cancer. 2015;6(10):976. https://doi.org/10.7150/jca.11936
  7. González-Correa C, Brown B, Smallwood R, Kalia N, Stoddard C, Stephenson T, et al. Virtual biopsies in Barrett's esophagus using an impedance probe. Annals of the New York Academy of Sciences. 1999;873(1):313-21. https://doi.org/10.1111/j.1749-6632.1999.tb09479.x
  8. Weijenborg PW, Rohof WO, Akkermans LM, Verheij J, Smout AJ, Bredenoord AJ. Electrical tissue impedance spectroscopy: a novel device to measure esophageal mucosal integrity changes during endoscopy. Neurogastroenterology & Motility. 2013;25(7):574-e458. https://doi.org/10.1111/nmo.12106
  9. Aberg P, Nicander I, Hansson J, Geladi P, Holmgren U, Ollmar S. Skin cancer identification using multifrequency electrical impedance-a potential screening tool. IEEE transactions on biomedical engineering. 2004;51(12):2097-102. https://doi.org/10.1109/TBME.2004.836523
  10. Martinsen ØG, Grimnes S, Karlsen J. Electrical methods for skin moisture assessment. Skin Pharmacology and Physiology. 1995;8(5):237-45. https://doi.org/10.1159/000211353
  11. Grimnes S, Martinsen ØG. Bioelectricity and bioimpedance basics. 2nd ed: Academic Press; 2008.
  12. Brown B, Wilson A, Bertemes-Filho P. Bipolar and tetrapolar transfer impedance measurements from volume conductor. Electronics Letters. 2000;36(25):2060-2. https://doi.org/10.1049/el:20001439
  13. Grimnes S, Martinsen ØG. Sources of error in tetrapolar impedance measurements on biomaterials and other ionic conductors. Journal of Physics D: Applied Physics. 2006;40(1):9. https://doi.org/10.1088/0022-3727/40/1/S02
  14. Kadir MA. Development of a multi-frequency system for medical application of Focused Impedance Method (FIM). Doctoral dissertation, University of Dhaka; 2018 http://repository.library.du.ac.bd:8080/handle/123456789/1245
  15. Islam N, Rabbani KS, Wilson A. The sensitivity of focused electrical impedance measurements. Physiological measurement. 2010;31(8):S97. https://doi.org/10.1088/0967-3334/31/8/S08
  16. Brown BH, Tidy JA, Boston K, Blackett AD, Smallwood RH, Sharp F. Relation between tissue structure and imposed electrical current flow in cervical neoplasia. The Lancet. 2000;355(9207):892-5. https://doi.org/10.1016/S0140-673699)09095-9
  17. Ghosh I, Mittal S, Banerjee D, Chowdhury N, Basu P. Study of Correlation of Cervical Epithelial Thickness With the Grade of Colposcopic Abnormality. International Journal of Gynecological Pathology. 2016;35(3):269-74. https://doi.org/10.1097/PGP.0000000000000249
  18. Bertemes-Filho P, Brown BH, Smallwood RH Wilson AJ, Standoff electrode (SoE): a new method for improving the sensitivity distribution of a tetrapolar probe, Physiological Measurement. 2003; 24:517–525. https://doi.org/10.1088/0967-3334/24/2/362
  19. Andreuccetti D FR, Petrucci C. An Internet resource for the calculation of the dielectric properties of body tissues in the frequency range 10 Hz - 100 GHz 1997. Available from: Website at http://niremf.ifac.cnr.it/tissprop/. IFAC-CNR, Florence (Italy).
Language: English
Page range: 176 - 183
Submitted on: Dec 18, 2018
Published on: Dec 31, 2018
Published by: University of Oslo
In partnership with: Paradigm Publishing Services
Publication frequency: 1 issue per year

© 2018 Muhammad Abdul Kadir, K. Siddique-e Rabbani, published by University of Oslo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.