Have a personal or library account? Click to login
Successful Extracorporeal Blood Purification Therapy Using Double Haemoadsorption Device in Severe Endotoxin Septic Shock: A Case Report Cover

Successful Extracorporeal Blood Purification Therapy Using Double Haemoadsorption Device in Severe Endotoxin Septic Shock: A Case Report

Open Access
|Nov 2022

Figures & Tables

Time course of haemodynamic parameters and laboratory examinations during double haemoadsorptive CRRT treatment_

Day 1
Day 2
Day 3
ParametersH.5.00 E.R.add.H 7.00 ICU add.H 8.00H 12.00 Start double adsorptionH 23.00H 8.00H 12.00 End of Cytosorb 1-st cycleH 19.00H 8.00H 12.00 End of Cytosorb 2-nd cycle
MAP (mmHg)72456658476258828090
HR (bpm)1101171001001171151201138480
H/UO (ml/h)300100-100000000
DB (μg/kg/min)00610101010200
NE (μg/kg/min)00.50.50.7111111
E (μg/kg/min)000.611110.60.40.4
UFR (ml/h)---000505050150
WBC, (103/μL)15.46029.500-29.400-25.55024.880-19.440-
Platelets, (103/μL)123.00053.000-53.500-17.00022.000-43.000-
CRP (mg/L)122146-145-354301-258-
PCT (ng/ml)-559---493460-396-
EAA, (Unit) 0.71 0.45
SCr, (mg/dl)1.52.2-2.2-1.61.3-1.2-
DOI: https://doi.org/10.2478/jccm-2022-0028 | Journal eISSN: 2393-1817 | Journal ISSN: 2393-1809
Language: English
Page range: 292 - 295
Submitted on: Feb 25, 2022
|
Accepted on: Oct 25, 2022
|
Published on: Nov 12, 2022
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2022 Stefano Ferraro, Stefania Bianzina, Sonila Mocka, Francesca Cappadona, Giovanni Battista Traverso, Fabio Massarino, Pasquale Esposito, published by University of Medicine, Pharmacy, Science and Technology of Targu Mures