Fig 1

Fig 2

Fig 3

Fig 4

Fig 5

Fig 6

Fig 7

Fig 8

Fig 9

Fig 10

Fig 11

Fig 12

Fig 13

Major oxide composition of analysed olivines (in wt%)_
| Sample | SiO2 | TiO2 | Al2O3 | FeO | MnO | MgO | CaO | Cr2O3 | NiO | Mg# |
|---|---|---|---|---|---|---|---|---|---|---|
| LZ2 | 41.34 | 0.01 | 0.02 | 8.18 | 0.12 | 49.84 | 0.04 | 0.02 | 0.41 | 92 |
| LZ4-X | 41.38 | 0.00 | 0.00 | 7.96 | 0.12 | 50.10 | 0.00 | 0.01 | 0.40 | 93 |
| LZ4-B | 39.69 | 0.04 | 0.04 | 13.92 | 0.23 | 45.48 | 0.32 | 0.03 | 0.23 | 87 |
| E-1 | 37.97 | 0.04 | 0.04 | 24.26 | 0.68 | 36.47 | 0.47 | 0.01 | 0.06 | 75 |
| HB | 40.18 | 0.05 | 0.23 | 13.04 | 0.15 | 45.45 | 0.32 | 0.18 | 0.37 | 87 |
| VRE-42 | 37.95 | 0.03 | 0.04 | 22.94 | 0.35 | 38.18 | 0.39 | 0.03 | 0.09 | 77 |
Filter and PMT details_ a) Detection packs (filters + PMT) for TL emission measurement_ All detection packs use a Schott KG3 (3 mm) as one of two filters; the second filter slot is variable_ Transmitted flux refers to the integrated flux through each filter set as a proportion of the total possible transmission, and the calculation for N is given in the text_ b) PSL filter combinations used, always detected with UV PMT_ No normalization is applied_
| a) TL detection packs. | ||||
|---|---|---|---|---|
| Detection pack [central λ, nm] | Variable filter slot | Detector | Transmitted flux (x10−2) | Norm. factor, N (x10−2) |
| 1 [330] | AHF-BrightLine HC 340/26 Interference (5 mm) | UV PMT | 1.92 | 0.57 |
| 2 [380] | Delta BP 365/50 EX-Interference (5 mm) | UV PMT | 3.79 | 1.13 |
| 3 [410] | AHF Brightline HC 414 (3.5 mm) | UV PMT | 5.50 | 1.50 |
| 4 [565] | AHF Brightline HC 575 (5 mm) | UV PMT | 3.60 | 0.10 |
| 5 [620] | AHF ET Bandpass 620 (3.5 mm) | UV PMT | 6.22 | 0.03 |
| 6 [565] | AHF Brightline HC 575 (5 mm) | Red PMT | 3.59 | 1.63 |
| 7 [620] | AHF ET Bandpass 620 (3.5 mm) | Red PMT | 6.22 | 2.60 |
| PMT, photomultiplier tubes; TL, thermoluminescence. | ||||
Dose recovery results: each row corresponds to measurements made on one aliquot_ The recycling ratio and zero-dose ratios are as defined in the text_ Note that aliquots were not preheated prior to the five days zero-dose measurement_ The recovered dose has been normalised by the given dose (116_0 Gy)_
| Sample | Emission | Recycling ratio | Zero-dose ratio (%) | Normalised recovered ratio | |
|---|---|---|---|---|---|
| Immediate | Five days | ||||
| HB | BSL380 | 1.11 ± 0.1 | 0.60 ± 1.24 | 88.44 ± 7.60 | 1.05 ± 0.08 |
| YSL380 | 0.97 ± 0.19 | 12.57 ± 5.52 | 0.88 ± 0.14 | ||
| IRSL410 | 1.10 ± 0.06 | 3.00 ± 0.52 | 36.62 ± 1.80 | 0.97 ± 0.04 | |
| LZ4-B | BSL380 | 0.93 ± 0.05 | 1.53 ± 0.57 | −0.24 ± 0.56 | 0.93 ± 0.05 |
| YSL380 | 0.95 ± 0.05 | 0.68 ± 0.68 | 0.80 ± 0.04 | ||
| IRSL410 | 0.93 ± 0.05 | 2.13 ± 0.50 | 3.54 ± 0.48 | 1.02 ± 0.05 | |
| LZ4-X | BSL380 | 0.96 ± 0.08 | −7.63 ± 1.72 | 27.81 ± 2.81 | 0.84 ± 0.05 |
| YSL380 | 1.00 ± 0.05 | 0.43 ± 0.43 | 0.00 | 0.89 ± 0.04 | |
| IRSL410 | 1.11 ± 0.06 | 3.90 ± 0.54 | 0.45 ± 0.45 | 1.01 ± 0.13 | |
| VRE-42 | BSL380 | 1.01 ± 0.05 | 1.98 ± 0.47 | 14.52 ± 0.85 | 0.96 ± 0.06 |
| IRSL410 | 0.97 ± 0.05 | 4.31 ± 0.51 | 0.56 ± 0.46 | 1.03 ± 0.06 | |
Olivine sample details_
| Location | Sample | Rock type | Latitude | Longitude |
|---|---|---|---|---|
| Lanzarote | LZ2 | Peridotite xenolith | 29.009361°N | 13.716361°W |
| Lanzarote | LZ4 | Basalt (B) and xenolith (X) | 29.021917°N | 13.711972°W |
| Eifel | E-1 | Trachy-Basalt | 50.348812°N | 7.187948°E |
| Hawaii | HB | Olivine sand | 18.936620°N | 155.646280°W |
| Argentina | VRE-42 | Basalt | 35.848694°S | 69.16200°W |