References
- [1] A. Lvovs, A. Mutule, “Customer Dissatisfaction Index and Its Improvement Costs”, Energetika un elektrotehnika Scientific Journal of RTU, Iss. 4, Vol. 27, 2010, pp. 21 - 26.10.2478/v10144-010-0014-2
- [2] F. Wester, E. Gulski, J. Smit, E. Groot, “Aspect of On-line and Off-line PD Diagnosis of Distribution Power Cables”, 2002 IEEE International Symposium on Electrical Insulation, pp. 553 - 556.
- [3] S.A.Boggs, “Partial Discharge-III Cavity Induced PD in Solid Dielectrics”, IEEE Electrical Insulation Magazine, Volume: 6, Issue: 6, pp.11 - 16, 1990.10.1109/57.63094
- [4] Yao Xiao, Jun Fu, Bin Hu, Xiaoping Li, Chunnian Deng, "Problems of voltage transducer in harmonic measurement", IEEE Transactions on Power Delivery, Vol. 19, No. 3, Jul 2004, pp. 1483 - 1487.10.1109/TPWRD.2004.829947
- [5] G. Stone, “Importance of bandwidth in PD measurement in operating motors and generators”, IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 7 , Iss. 1, Feb 2000, pp. 6 - 11.10.1109/94.839335
- [6] G.M. Hashmi, M. Lehtonen, M. Nordman, ”Calibration of on-line partial discharge measuring system using Rogowski coil in coveredconductor overhead distribution networks”, IET Science, Measurement & Technology, Vol. 5, Iss. 1, Jan 2011, pp. 5 - 13.10.1049/iet-smt.2009.0124
- [7] Xin Li, Chengrong Li, Wei Wang, Bin Wei, Weijiang Wan, “Partial discharge measurement in XLPE cable joint by using VHF sensor”, 2004 IEEE International Conference on Solid Dielectrics, ICSD 2004, Vol.2, pp. 669 - 671.
- [8] G. Robles, J.M. Martinez-Tarifa, M. V. Rojas-Moreno, J. Sanz-Feito, “Inductive Sensor for Measuring High Frequency Partial Discharges Within Electrical Insulation”, IEEE Transactions on Instrumentation and Measurement, Vol. 58, Iss. 11, Nov 2009, pp. 3907 - 391.10.1109/TIM.2009.2021239
- [9] Baocheng Wang, Deyu Wang, Weiyang Wu, “A Rogowski coil current transducer designed for wide bandwidth current pulse measurement”, 2009 IEEE 6th International Power Electronics and Motion Control Conference, IPEMC '09, pp. 1246 - 1249.10.1109/IPEMC.2009.5157575
- [10] P. Valatka, V. Sučila, G. Daukšys, "Investigation of the Voltage Influence on Partial Discharge Characteristic Parameters in Solid Insulation", Electronics and Electrical Engineering, No.10 (106), 2010, pp. 63 - 66.
- [11] G.J. Paoletti, A. Golubev, "Partial discharge theory and technologies related to medium-voltage electrical equipment", IEEE Transactions on Industry Applications, Vol. 37, Jan/Feb 2001, pp. 90 - 103.10.1109/28.903131
- [12] N. Ida, “Engineering Electromagnetics” (Second Edition), Springer New York, 2004.10.1007/978-0-387-68624-0
- [13] M. Rezaee, H. Heydari, Mutual inductances comparison in Rogowski coil with circular and rectangular cross-sections and its improvement; 3rd IEEE Conference on Industrial Electronics and Applications, 2008 (ICIEA 2008), pp. 1507 - 1511.10.1109/ICIEA.2008.4582770
- [14] L. Kütt, J. Järvik, H. Mõlder, J. Kilter, S. Muhammad, Magnetic Current Sensor Stray Components in High Frequency Operation and their Effects, 11th Conference on Environment and Electrical Engineering (EEEIC) 2012, 6 p.10.1109/EEEIC.2012.6221451
- [15] M. Shafiq, L. Kütt, M. Lehtonen, T. Nieminen, G. M. Hashmi, “Parameters Identification and Modeling of High Frequency Current Transducer for Partial Discharge Measurements”, IEEE Sensors Journal, Vol. 13, Iss. 3, Mar 2013, pp. 1081 - 1091.10.1109/JSEN.2012.2227712
- [16] L. Kütt, M. Shafiq, J. Järvik, M. Lehtonen, J. Kilter, "Air-core inductive current sensor for fast transients measurements in distribution networks", 2012 Electric Power Quality and Supply Reliability Conference (PQ2012), 4 p.10.1109/PQ.2012.6256234
- [17] L. Kütt, M. Shafiq, M. Lehtonen, H. Mõlder, J. Järvik, “Sensor Resonance and its Influence on the Measurement Results of Fast Transients”, 2013 International Conference on Power Systems Transients (IPST2013), 7 p.
- [18] N. Breners, N. Skobeleva, “Mathematical Models for Choice of Measures on Functioning Reliability Increase of Power Transformers”, Energetika un elektrotehnika Scientific Journal of RTU, Iss. 4, Vol. 27, 2010, pp. 64 - 68.