Have a personal or library account? Click to login
A Transient Method for Determining Thermal Diffusivity of Tobacco Stems Cover

A Transient Method for Determining Thermal Diffusivity of Tobacco Stems

By: NN Barthakur and  NP Arnold  
Open Access
|Jan 2015

Abstract

A microwave generator and a closed-circuit wind tunnel were used to measure the thermal diffusivity of tobacco (Nicotianatabacum L.) stems in vivo by the unsteady-state method. A simple mathematical model for heat flow, based on Fourier's heat-conduction equation and Newton's law of cooling, was used in this study. The microwave method was found to be relatively rapid as both heating and cooling of a cylindrical stem in an air stream could be completed in approximately 30 minutes for thermal-diffusivity determinations. Thermal-diffusivity value of the tobacco stems, containing 94 % moisture and a mean stem temperature of 30°C, was found to be (1.38 ± 0.06) × 10-7 m2 s-1. The coefficient of variation for the measurements did not exceed 1.4 % as determined through the analysis of cooling curves for five different air-flow rates over the stems. This study showed that the microwave technique could be effectively used to determine both accurately and reliably the thermal diffusivity of tobacco stems in vivo.

Language: English
Page range: 321 - 326
Submitted on: Aug 8, 1988
Accepted on: Feb 2, 1989
Published on: Jan 6, 2015
Published by: Institut für Tabakforschung GmbH
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2015 NN Barthakur, NP Arnold, published by Institut für Tabakforschung GmbH