Have a personal or library account? Click to login
Operation of the Pumping System with Rods Cover

Abstract

The asynchronous electric motor is used in the electric stock industry. The inverter adjusts the speed of an asynchronous motor from level 0 to rated speed. An oil pumping plant comprises the bottom machine and the surface machine. The lower machine consists of the depth pump, gas and sand separator, extraction pipe, pump rods. The surface tool includes the pump unit and other equipment. In turn, the pumping unit consists of the rocker, mechanical gearbox, connecting rods, cranks and electric motor. In pump extraction processes, maximum engine speed and / or power is not required. Significant reductions in power consumption can be achieved by adjusting the engine speed with the help of a converter. This solution can reduce production costs and increase productivity by up to 50-60%. The paper is dedicated to studying the regulation of the asynchronous electric motor using a converter controlled by a Siemens PLC. The equipment used is didactic, being produced by the company ASTI Romania.

DOI: https://doi.org/10.2478/bipcm-2021-0011 | Journal eISSN: 2537-4869 | Journal ISSN: 1011-2855
Language: English
Page range: 39 - 46
Submitted on: Mar 26, 2021
Accepted on: May 27, 2021
Published on: Feb 23, 2022
Published by: Gheorghe Asachi Technical University of Iasi
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2022 Ionel Sorin Ştefan, Cristian Pătrăscioiu, published by Gheorghe Asachi Technical University of Iasi
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.