Have a personal or library account? Click to login
Cost-Effective Data Glove and Mechanical Hand For the Analysis and Simulation of Finger Movements Cover

Cost-Effective Data Glove and Mechanical Hand For the Analysis and Simulation of Finger Movements

Open Access
|Dec 2024

References

  1. Brandes R, Lang F, Schmidt R (Ed). Physiologie des Menschen: mit Pathophysiologie. Berlin: Springer; 2019
  2. Connolly, James & O'Flynn, Brendan & Torres Sanchez, Javier & Condell, Joan & Curran, Kevin & Gardiner, Philip & Downes, Barry. (2015). Integrated Smart Glove for Hand Motion Monitoring
  3. Wang Qi & Liu Yu (2018). Review of Optical Fiber Bending/Curvature Sensor. Measurement. 130. 10.1016/j.measurement.2018.07.068.
  4. Lee, Yun & Wu, Ruh-Hua & Xu, S.. (2011). Applications of linear Hall-effect sensors on angular measurement. Proceedings of the IEEE International Conference on Control Applications. 479-482. 10.1109/CCA.2011.6044465.
  5. J. Neely and P. Restle, "Capacitive Bend Sensor", patent no. US5610528A
  6. De Pasquale, Giorgio. (2018). Glove-based systems for medical applications: review of recent advancements. Journal of Textile Engineering & Fashion Technology. 4. 10.15406/jteft.2018.04.00153.
  7. O'Flynn, Brendan & Torres Sanchez, Javier & Connolly, James & Condell, Joan & Curran, Kevin & Gardiner, Philip. (2013). Novel smart sensor glove for arthritis rehabiliation. 1-6. 10.1109/BSN.2013.6575529
  8. Davarzani, Shokoufeh & Pajouh, Mohammad. (2020). Design and Fabrication of Sensing System for Rehabilitation of Finger. 1-5. 10.1109/ICEE50131.2020.9260601.
  9. Heijde, D & Hof, M & Riel, Piet & Putte, L. (1993). Development of a Disease Activity Score based on judgment in clinical practice by rheumatologists. The Journal of rheumatology. 20. 579-81.
  10. V. Majithia and S. Geraci, "Rheumatoid Arthritis: Diagnosis and Management," [Online]. Available: https://www.sciencedirect.com/science/article/abs/pii/S0002934307003610.
  11. Henderson, Jeffrey & Condell, Joan & Connolly, James & Kelly, Daniel & Curran, Kevin. (2021). Review of Wearable Sensor-Based Health Monitoring Glove Devices for Rheumatoid Arthritis. Sensors. 21. 1576. 10.3390/s21051576.
DOI: https://doi.org/10.2478/aucts-2024-0003 | Journal eISSN: 2668-6449 | Journal ISSN: 1583-7149
Language: English
Page range: 24 - 27
Published on: Dec 31, 2024
Published by: Lucian Blaga University of Sibiu
In partnership with: Paradigm Publishing Services
Publication frequency: 1 issue per year

© 2024 Zăbavă Dumitru Viorel, Neghină Mihai, published by Lucian Blaga University of Sibiu
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.