Have a personal or library account? Click to login
A twelve-month clinical trial comparing the bracket failure rates of light-cured resin-modified glass-ionomer adhesive and acid-etch chemical-cured composite Cover

A twelve-month clinical trial comparing the bracket failure rates of light-cured resin-modified glass-ionomer adhesive and acid-etch chemical-cured composite

By: Peter V. Fowler  
Open Access
|Jan 2024

References

  1. Newman GV. A post-treatment survey of direct bonding of metal brackets. Am J Orthod 1978; 74: 197-206.
  2. Geiger AM, Gorelick L, Gwinnett AJ. Bond failure rates of facial and lingual attachments. J Clin Orthod 1983; 17: 165-9.
  3. Zachrisson BU. A post-treatment evaluation of direct bonding in Orthodontics. Am J Orthod 1977; 71: 173-89.
  4. Gorelich L, Geiger A, Gwinnett AJ. Incidence of white spot formation after bonding and banding. Am J Orthod 1982; 81: 93-8.
  5. Zachrisson BU. Iatrogenic damage in orthodontic treatment. J Clin Orthod 1978; 12: 208-20.
  6. Swartz ML, Phillips RW, Clarke HE. Long term release from glass-ionomer cements. J Dent Res 1984: 63: 158-60.
  7. Gomes J, Paiffer -AC, Oliveira CM, Navarro NFL,Taga MT, Carvalho RM. Fluoride uptake of glass-ionomer cements in vitro. J Dent Res 1996; 75: 68.
  8. Geiger AM, Gorelick L, Gurinnett JA, Benson BJ. Reducing white spot lesions in orthodontic populations with fluoride rinsing Am J Orthod 1992; 101: 403-7.
  9. Marcusson A, Novevall L-I, Persson M. White spot reduction when using glass-ionomer cement for bonding in Orthodontics: a longitudinal and comparative study. Eur J Orthod 1997; 198: 233-42.
  10. Ortendahl T, Thilander B, Svanbery M. Mutans streptococci and incipient caries adjacent to glass-ionomer cement or resin based composite in Orthodontics. Am J Orthod 1997; 112: 271-4.
  11. Fricker JP. A 12 month clinical evaluation of a light activated glass polyalkenoate (ionomer) cement for the direct bonding of orthodontic brackets. Am J Orthod 1994; 105: 502-5.
  12. Silverman BE, Cohen M, Demke R, Silverman M. A new glass-ionomer cement that bonds brackets to teeth without etching in the presence of saliva. Am J Orthod 1995; 108: 231-6.
  13. Fricker JP. Bonding and debonding with light activated resin-modified glass-ionomer cement Aust Orthod J 1995; 14: 78-80.
  14. Andrews LF. Straight wire: the concept and appliance. San Diego: LA Wells Co., 1989 Cpt 8: 159-70.
  15. Fowler PV. Variations in perception of the ideal bracket location and its implications for the preadjusted Edgewise appliance. Brit J Orthod. 1990: 17; 305-10.
  16. Fricker JP. A new self-curing resin-modified glass-ionomer cement for the direct bonding of orthodontic brackets. Aust Orthod J 1997; 14: 247-9.
  17. Silverman BE, Cohen M, Demke R, Silverman M. A new self-curing hybrid glass-ionomer. J Clin Orthod. 1997; 31: 315-8.
  18. Jobalia SB, Valente RM, de Rijk WG, Begole EA, Evans CA. Bond strength of visible light cured glass-ionomer orthodontic cement. Am J Orthod 1997; 112: 205-8.
  19. Fricker JP. A 12 month clinical comparison of resin-modified light activated adhesives for the cementation of orthodontic molar bands Am J Orthod 1997; 12: 239-43.
DOI: https://doi.org/10.2478/aoj-1998-0013 | Journal eISSN: 2207-7480 | Journal ISSN: 2207-7472
Language: English
Page range: 186 - 190
Submitted on: Jan 1, 1998
Accepted on: Jul 1, 1998
Published on: Jan 13, 2024
Published by: Australian Society of Orthodontists Inc.
In partnership with: Paradigm Publishing Services
Publication frequency: 1 issue per year

© 2024 Peter V. Fowler, published by Australian Society of Orthodontists Inc.
This work is licensed under the Creative Commons Attribution 4.0 License.