Evaluation of the Influence of the Supply Pressure on Functional Parameters of the Impulse Low-Pressure Gas-Phase Injector
Abstract
The article presents research results referring to the influence of supply pressure on the functional parameters of the impulse low-pressure gas-phase injector. The study was done on the original stand for flow test of gas-phase injectors. In the indirect evaluation, with the initial parameters and the length of the forced impulse, the current line, acceleration and pressure sensor courses were used. Apart from the volumetric flow rate, the analysed parameters were the time periods of the injector opening and closing process. Those time segments were composed of response time and opening/closing time, the sum of which gives time of full opening. Functional relationships describing the volumetric flow rate, time of full opening and closing are presented, which are helpful not only in comparative tests of different injectors, but also in modelling the operation of gas injector or algorithms of gas supply control system. The reference to the volumetric flow rate allowed to indicate possible causes of variability of this parameter depending on the supply pressure.
© 2021 Dariusz Szpica, Andrzej Borawski, Grzegorz Mieczkowski, Michał Kusznier, Mohamed M. Awad, Adel M. Sadik, Mohammed Sallah, published by Bialystok University of Technology