Skip to main content
Have a personal or library account? Click to login
Comparative Evaluation of Single CNN Models, Test-Time Augmentation, and Weighted Ensembling for Knee Osteoarthritis Severity Classification Cover

Comparative Evaluation of Single CNN Models, Test-Time Augmentation, and Weighted Ensembling for Knee Osteoarthritis Severity Classification

Open Access
|Oct 2026
Read online

Abstract

Knee osteoarthritis (KOA) severity grading via the Kellgren–Lawrence (KL) system suffers from substantial interrater variability, motivating automated deep learning approaches. This study presents a comparative framework combining EfficientNet-B3 and ConvNeXt-Tiny, integrated through test-time augmentation (TTA), prediction averaging over augmented image views, and weighted probability-level ensembling, for four-class KOA severity classification (G0+G1, G2, G3, G4) from knee radiographs. A total of 8260 X-ray images were processed through region-of-interest cropping, contrast-limited adaptive histogram equalisation (CLAHE), and class-aware augmentation, with both learners trained independently using Focal Loss under classweighted and standard sampling. Contrary to the initial hypothesis, ConvNeXt-Tiny alone achieved the highest or nearhighest accuracy (up to 83.8 %), while the weighted ensemble (15 %/85 %) yielded indistinguishable, rather than superior, performance per bootstrap confidence intervals. TTA consistently improved accuracy without requiring retraining or architectural modification. Misclassifications were largely confined to adjacent severity grades, yielding a quadratic weighted kappa of approximately 0.857, indicating preservation of the ordinal KL grading structure – arguably more clinically relevant than raw accuracy. The Minimal (G2) class was the principal source of confusion across confusion-matrix, receiver operating characteristic (ROC), precision–recall (PR), t-distributed stochastic neighbour embedding (t-SNE), and gradient-weighted class activation mapping (Grad-CAM) analyses, reflecting genuine radiographic ambiguity rather than an architecture-specific weakness. Beyond its clinical findings, the proposed dual-branch, multi-resolution inference pipeline and TTA-based probability fusion offer a transferable design pattern for multimedia diagnostic decision-support systems reconciling heterogeneous visual encoders at inference time. These results suggest TTA yields more reliable returns than multi-model ensembling for this task. However, these findings are based on retrospective evaluation using a single OAI-derived dataset, and their clinical applicability remains to be established through external validation and prospective radiologist assessment.

DOI: https://doi.org/10.2478/acss-2026-0016 | Journal eISSN: 2255-8691 | Journal ISSN: 2255-8683 (formerly 2255-8691)
Language: English
Page range: 187 - 205
Submitted on: Aug 20, 2026
Accepted on: Oct 12, 2026
Published online: Oct 28, 2026
Published in print: Jan 1, 2026
Published by: Riga Technical University
In partnership with: Paradigm Publishing Services
Publication frequency: Volume open

© 2026 Huseyin Coskun, Zekeriya Katılmış, published by Riga Technical University
This work is licensed under the Creative Commons Attribution 4.0 License.