Have a personal or library account? Click to login
Revising Organic Vapour Respirator Cartridge Change Schedule: a Case Study of a Paint Plant in Iran Cover

Revising Organic Vapour Respirator Cartridge Change Schedule: a Case Study of a Paint Plant in Iran

Open Access
|Mar 2013

Abstract

After having revised the change schedule for organic vapour respirator cartridges in a paint plant in Iran, we established that it did not provide adequate protection against organic vapours at some workplaces and needed shortening from (48 to 72) h to 4 h. The revision also showed that relying on odour thresholds as the primary means to determine the time to change a chemical cartridge was not effective and that the National Institute for Occupational Safety and Health (NIOSH) MultiVapor service life software program could be applied to develop cartridge change schedules adjusted to specific workplaces.

DOI: https://doi.org/10.2478/10004-1254-64-2013-2256 | Journal eISSN: 1848-6312 | Journal ISSN: 0004-1254
Language: English, Croatian, Slovenian
Page range: 133 - 138
Published on: Mar 26, 2013
Published by: Institute for Medical Research and Occupational Health
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2013 Ali Karimi, Mehdi Jahangiri, Forough Zare Derisi, Mohammad Amin Nourozi, published by Institute for Medical Research and Occupational Health