Have a personal or library account? Click to login

The sensitivity, specificity, and clinical relevance of gel versus tube DATs in the clinical immunology laboratory

By:
Paid access
|May 2020

References

  1. Coombs RR. Historical note: past, present and future of the antiglobulin test. Vox Sang 1998;74:67-73.10.1046/j.1423-0410.1998.7420067.x
  2. Lapierre Y, Rigal D,Adam J, et al. The gel test: a new way to detect red cell antigen-antibody reactions. Transfusion 1990;30:109-13.10.1046/j.1537-2995.1990.30290162894.x2305438
  3. Nathanlang O, Chuansumrit A, Prayoonwitat W, Siripoonya P,SriphasialT. Comparison between the conventional tube technique and the gel technique in direct antiglobulin tests. Vox Sang 1997;72:169- 71.10.1046/j.1423-0410.1997.7230169.x9145487
  4. Moulds JM, Diekman L, Wells TD. Evaluation of column technology for direct antiglobulin testing. Immunohematology 1998;14:146-8.10.21307/immunohematology-2019-683
  5. Cate JC and Reilly N. Evaluation and implementation of the gel test for indirect antiglobulin testing in a community hospital laboratory. Arch Pathol Lab Med 1999;123:693-7.10.5858/1999-123-0693-EAIOTG10420225
  6. Reis KJ, Chachowski R, Cupido A. Column agglutination technology: the antiglobulin test. Transfusion 1993;33:639-43.10.1046/j.1537-2995.1993.33893342744.x8342229
  7. Dittmar K, Procter JL, Cipolone K, Njoroge JM, Miller J, Stroncek DF. Comparison of DATs using traditional tube agglutination to gel column and affinity column procedures. Transfusion 201;41: 1258-62.10.1046/j.1537-2995.2001.41101258.x11606825
  8. Judd WJ, Steiner EA, Knafl PC, Masters C. The gel test: use in the identification of unexpected antibodies to blood group antigens. Immunohematology 1998;14:59-62.10.21307/immunohematology-2019-661
  9. Weisbach V, Ziener R, Zimmerman A, Glaser J, Zingsam R, Eckstein R. Comparison of the performance of four microtube column agglutination systems in the detection of red cell alloantibodies. Transfusion 1999;39:1045-50.10.1046/j.1537-2995.1999.39101045.x10532596
  10. Champagne K,Spruell P, Chen L,Voll A, Schlanser G. Moulds M. Comparison of affinity column technology and LISS tube tests. Immunohematology 1999;15:149-51.
  11. Lai M, Rumi C, D’Onofrio G, Voso MT, Leone G. Clinically significant autoimmune hemolytic anemia with a negative direct antiglobulin test by routine tube test and positive by column agglutination method. Immunohematology 202;18: 109-13.10.21307/immunohematology-2019-526
  12. Tissot JD, Kiener C, Burand B, Schneider P. The direct antiglobulin test: still a place for the tube technique? Vox Sang 1999;77:223-6.10.1046/j.1423-0410.1999.7740223.x
DOI: https://doi.org/10.21307/immunohematology-2019-433 | Journal eISSN: 1930-3955 | Journal ISSN: 0894-203X
Language: English
Page range: 118 - 121
Published on: May 15, 2020
Published by: American National Red Cross
In partnership with: Paradigm Publishing Services
Publication frequency: 4 times per year

© 2020 N. Paz, D. Itzhaky, M.H. Ellis, published by American National Red Cross
This work is licensed under the Creative Commons License.