Have a personal or library account? Click to login
Cryopreservation of red blood cell units with a modified method of glycerolization and deglycerolization with the ACP 215 device complies with American and European requirements Cover

Cryopreservation of red blood cell units with a modified method of glycerolization and deglycerolization with the ACP 215 device complies with American and European requirements

By: J. List,  M. Horvath,  G. Weigel and  G.C. Leitner  
Paid access
|Dec 2019

References

  1. Leitner GC, Dettke M, List J, Worel N, Weigel G, Fischer MB. Red blood units collected from bone marrow harvests after mononuclear cell selection qualify for autologous use. Vox Sang 2010;98(3 Pt 1):e284–9.10.1111/j.1423-0410.2009.01300.x20059756
  2. Leitner GC, Rach I, Horvath M, et al. Collection and storage of leukocyte depleted whole blood in autologous blood predeposit in elective surgery programs. Int J Surg 2006;4:179–83.10.1016/j.ijsu.2005.10.01417462343
  3. Standards for blood banks and transfusion services. 25th ed. Bethesda, MD: AABB, 2008:31–2, 62.
  4. Meryman HT, Hornblower M. A method for freezing and washing red blood cells using a high glycerol concentration. Transfusion 1972;12:145–56.10.1111/j.1537-2995.1972.tb00001.x5026166
  5. Valeri CR, Valeri DA, Anastasi J, Vecchione JJ, Dennis RC, Emerson CP. Freezing in the primary polyvinylchloride plastic collection bag: a new system for preparing and freezing nonrejuvenated and rejuvenated red blood cells. Transfusion 1981;21:138–49.10.1046/j.1537-2995.1981.21281178148.x7222198
  6. Sowemimo-Coker SO. Red blood cell hemolysis during processing. Transfus Med Rev 2002;16:46–60.10.1053/tmrv.2002.2940411788929
  7. Ackley RJ, Lee-Stroka AH, Bryant BJ, Stroncek DF, Byrne KM. Cryopreserving and deglycerolizing sickle cell trait red blood cell components using an automated cell-processing system. Immunohematology 2008;24:107–12.10.21307/immunohematology-2019-281
  8. Lagerberg JW, Truijens-de Lange R, de Korte D, Verhoeven AJ. Altered processing of thawed red cells to improve the in vitro quality during postthaw storage at 4 degrees C. Transfusion 2007;47:2242–9.10.1111/j.1537-2995.2007.01453.x17714415
  9. Lelkens CC, Noorman F, Koning JG, et al. Stability after thawing of RBCs frozen with the high- and low-glycerol method. Transfusion 2003;43:157–64.10.1046/j.1537-2995.2003.00293.x12559010
  10. Council of Europe. Guide to the preparation, use and quality assurance of blood components. 13th ed. Strasbourg, France: Council of Europe Publishing; 2007:137–40.
  11. Council of Europe. Guide to the preparation, use and quality assurance of blood components. 13th ed. Strasbourg, France: Council of Europe Publishing; 2007:133–6.
  12. Roback, JD, ed. Technical manual. 16th ed. Bethesda, MD: AABB, 2008:955.
  13. Leitner GC, Neuhauser M, Weigel G, Kurze S, Fischer MB, Höcker P. Altered intracellular purine nucleotides in gamma-irradiated red blood cell concentrates. Vox Sang 2001;81: 113–18.10.1046/j.1423-0410.2001.00082.x11555471
  14. Nagy S, Paál M, Kõszegi T, Ludány A, Kellermayer M. ATP and integrity of human red blood cells. Physiol Chem Phys Med NMR 1998;30:141–8.
  15. Holme S. Current issues related to the quality of stored RBCs. Transfus Apher Sci 2005;33:55–61.10.1016/j.transci.2005.02.00415975849
  16. Hess JR. An update on solutions for red cell storage. Vox Sang 2006;91:13–19.10.1111/j.1423-0410.2006.00778.x16756596
  17. Besselink GA, Ebbing IG, Hilarius PM, de Korte D, Verhoeven AJ, Lagerberg JW. Composition of the additive solution affects red blood cell integrity after photodynamic treatment. Vox Sang 2003;85:183–9.10.1046/j.1423-0410.2003.00358.x14516448
  18. Hess JR, Lippert LE, Derse-Anthony CP, et al. The effects of phosphate, pH, and AS volume on RBCs stored in saline-adenine-glucose-mannitol solutions. Transfusion 2000;40:1000–6.10.1046/j.1537-2995.2000.40081000.x10960529
  19. Bandarenko N, Hay SN, Holmberg J, et al. Extended storage of AS-1 and AS-3 leukoreduced red blood cells for 15 days after deglycerolization and resuspension in AS-3 using an automated closed system. Transfusion 2004;44:1656–62.10.1111/j.1537-2995.2004.04101.x15504173
  20. Leitner GC, Jilma-Stohlawetz P, Stiegler G, et al. Quality of packed red blood cells and platelet concentrates collected by multicomponent collection using the MCS plus device. J Clin Apher 2003;18:21–5.10.1002/jca.1004912717789
  21. Picker SM, Radojska SM, Gathof BS. Prospective evaluation of double RBC collection using three different apheresis systems. Transfus Apher Sci 2006;35:197–205.10.1016/j.transci.2006.08.00417097350
  22. Picker SM, Radojska SM, Gathof BS. In vitro quality of red blood cells (RBCs) collected by multicomponent apheresis compared to manually collected RBCs during 49 days of storage. Transfusion 2007;47:687–96.10.1111/j.1537-2995.2007.01172.x17381628
  23. Valeri CR, Ragno G, Pivacek L, O’Neill EM. In vivo survival of apheresis RBCs, frozen with 40-percent (wt/vol) glycerol, deglycerolized in the ACP 215, and stored at 4 degrees C in AS-3 for up to 21 days. Transfusion 2001;41:928–32.10.1046/j.1537-2995.2001.41070928.x11452162
  24. Valeri CR, Ragno G, Pivacek LE, et al. A multicenter study of in vitro and in vivo values in human RBCs frozen with 40-percent (wt/vol) glycerol and stored after deglycerolization for 15 days at 4 degrees C in AS-3: assessment of RBC processing in the ACP 215. Transfusion 2001;41:933–9.10.1046/j.1537-2995.2001.41070933.x11452163
  25. Valeri CR, Srey R, Tilahun D, Ragno G. The in vitro quality of red blood cells frozen with 40 percent (wt/vol) glycerol at -80 degrees C for 14 years, deglycerolized with the Haemonetics ACP 215, and stored at 4 degrees C in additive solution-1 or additive solution-3 for up to 3 weeks. Transfusion 2004;44:990–5.10.1111/j.1537-2995.2004.04001.x15225238
  26. Moroff G, Meryman HT. Influence of glycerol on ATP and 2,3-DPG levels of human erythrocytes. Vox Sang 1979;36:244–51.10.1111/j.1423-0410.1979.tb04432.x462914
DOI: https://doi.org/10.21307/immunohematology-2019-152 | Journal eISSN: 1930-3955 | Journal ISSN: 0894-203X
Language: English
Page range: 67 - 73
Published on: Dec 1, 2019
Published by: American National Red Cross
In partnership with: Paradigm Publishing Services
Publication frequency: 4 issues per year

© 2019 J. List, M. Horvath, G. Weigel, G.C. Leitner, published by American National Red Cross
This work is licensed under the Creative Commons License.