References
- Seyran Ghaderi, Masoud Ayatollahi Mehrgardi, “Prussian blue-modified nanoporous gold film electrode for amperometric determination of hydrogen peroxide”, Bioelectrochemistry, Vol. 98 (2014) 64–69
- C. Wang, S. Chen, Y. Xiang, W. Li, X. Zhong, X. Che, J. Li, “Glucose biosensor based on the highly efficient immobilization of glucose oxidase on Prussian blue-gold nanocomposite films”, J. Mol. Catal. B Enzym. Vol. 69 (2011) 1–7.
- G.-H. Wang, L.-M. Zhang, “Using novel polysaccharide-silica hybrid material to construct an amperometric biosensor for hydrogen peroxide”, J. Phys. Chem. B Vol. 110 (2006) 24864–24868.
- E.M.I. Mala Ekanayake, D.M.G. Preethichandra, Keiichi Kaneto, “Bi- functional amperometric biosensor for low-concentration hydrogen peroxide measurements using polypyrrole immobilizing matrix “ Sensors and Actuators B, Volume 132, Issue 1, 2008, pp. 166-171.
- Kuan-ChungFang, et. al., “Realization of anultra-sensitive hydrogen peroxide sensor with conductance change of horseradish peroxidase- immobilized polyaniline and investigation of the sensing mechanism”, Biosensors and Bioelectronics, Vol. 55(2014)294–300.
- Mehmet Senela, Emre Cevika, and M. Fatih Abasıyanık, “Amperometric hydrogen peroxide biosensor based on covalent immobilization of horseradish peroxidase on ferrocene containing polymeric mediator”, Sensors and Actuators B Vol. 145 (2010) 444–450.
- Chandrakant K. Tagad, et. al., “Green synthesis of silver nanoparticles and their application for the development of optical fiber based hydrogen peroxide sensor”, Sensors and Actuators B 183 (2013) 144– 149.
- Ali A. Ensafi, M. Mokhtari Abarghoui, and B. Rezaei, “Electrochemical determination of hydrogen peroxide usingcopper/porous silicon based non-enzymatic sensor”, Sensors and Actuators B 196 (2014) 398–405.
- Yonghai Song, “A novel hydrogen peroxide sensor based on horseradish peroxidase immobilized in DNA films on a gold electrode”, Sensors and Actuators B, Vol. 114 (2006) 1001–1006.
- J.L. Tang, et. al., “Lipid membrane immobilized horseradish peroxidase biosensor for amperometric determination of hydrogen peroxide, Biosens. Bioelectron. Vol. 18,(2003) 867–872.
- G. Wang, J.J. Xu, H.Y. Chen, and Z.H. Lu, “Amperometric hydrogen peroxide biosensor with sol–gel/chitosan network-like film as immobilization matrix”, Biosens. Bioelectron., Vol. 18 (2003) 335–343.
- E.M.I.Mala Ekanayake, D.M.G. Preethichandra, Keiichi Kaneto, “Polypyrrole Nanotube Array sensor for Enhanced Adsorption of Glucose oxidase in Glucose Biosensors” Biosensors and Bioelectronics, Volume 23, Issue 1, 30 , August 2007, pp. 107-113
- D.M.G.Preethichandra, E.M.I.mala Ekanayake and K. Kaneto, “Development of Low-Cost Nano-biosensors to Enhance the Rural Healthcare Service”, 6th Intl Conference on Sensing technology (ICST2012), December 2012, Kolkata, India.
- D.M.G.Preethichandra, “Enhancing Sensitivity of Glucose Biosensors Using Pulsed Deposition of Polypyrrole on ITO Electrodes”, 13th International Discussion and Conference on nano Interface Controlled Electronic devices(IDC-NICE2013), Oct. 2013, Hiroshima, Japan.
- D.M.G.Preethichandra, E.M.I.mala Ekanayake and K. Kaneto, “Characteristics of Glucose Biosensors with Glucose Oxidase Deposited Under High Electric Field”, International Instrumentation and Measurement Technology Conference, (I2MTC2012), May, 2012, Graz, Austria.
- D.M.G.Preethichandra, E.M.I.mala Ekanayake and K. Kaneto, “Enhanced Glucose nano-Biosensor by Pulsed deposition of Conducting Polymer on ITO/Pt”, International Symposyum on medical Measurements and Applications(MeMEA2012), May, 2012 Budapest, Hungary.