P. Shuk,  R. Jantz and  H.-U. Guth  
Open Access
|Mar 2012

Abstract

Calcium doped lanthanum and yttrium manganite electrode materials with oxygen deficiency and low polarization resistance (<30Ω*cm2at 600°C) were tested in new advanced electrochemical sensor for the oxygen measurements. Oxygen sensor with oxide electrodes was showing fast response (t95~5s at 600°C), good reproducibility (±0.04% O2) and long term stability at different oxygen concentration.